• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Rate
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

2 Way Flow Control Proportional Valves

Picture for category 2 Way Flow Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceActuation TypeSeal MaterialConnection SizeConnection TypeBody MaterialDivisionDivisionMaximum Kinematic ViscosityMaximum Operating PressureMinimum Operating TemperatureWeightOverride FunctionalityCoil TypeOperation TypePower ConsumptionInstallation TorqueCoil Nut Tightening TorqueMaximum Inlet Pressure RatingMaximum Operating TemperatureFunctionFrequencyFor Fluid TypeValve MaterialOperating TemperatureFilter Efficiency RatingWire Mesh Screen IncludedVariation of Opening PointCavity SizeFlow DirectionFlow Rate AccuracyCurrentConfigurationFlow RateLeak RateHysteresisMaximum Flow RateVariation of Closing PointMinimum Pressure DifferentialSeal MaterialActuation TypeFlow RateConfiguration
JP04P2100NL
Quote Required
TBD
ElectricalNitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)210 bar-34 °C0.28 lbn/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W30 Nm4.1 Nm210 bar+121 °CProportional Flow Control/Regulator100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC ANormally Open, Pressure Compensated36 L/min780 @ 3000 PSI (210 BAR) cm3/min7%9.5 Gal/min25% of Input Signal200 psiNitrileElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2100V
Quote Required
TBD
ElectricalFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28n/a5/8" Super Coil High Watt (CAP)Solenoid Operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2100VL
Quote Required
TBD
ElectricalFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28n/a5/8" Super Coil High Watt (CAP)Solenoid Operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2101N
Quote Required
TBD
ElectricalNitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)210 bar-30 °F0.28 lbn/a5/8" Super Coil High Watt (CAP)Solenoid Operated28 W22 lb-ft3 lb-ft3000 psi+250 °FProportional Flow Control/Regulator100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC ANormally Open, Pressure Compensated36 L/min780 @ 3000 PSI (210 BAR) cm3/min7%36.0 L/min25% of Input Signal13.8 barNitrileElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2101NL
Quote Required
TBD
ElectricalNitrilen/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-300.28n/a5/8" Super Coil High Watt (CAP)Solenoid Operated282233000+250Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200NitrileElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2101V
Quote Required
TBD
ElectricalFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28n/a5/8" Super Coil High Watt (CAP)Solenoid Operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2101VL
Quote Required
TBD
ElectricalFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28n/a5/8" Super Coil High Watt (CAP)Solenoid Operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2150N
Quote Required
TBD
Electrical, ManualNitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)210 bar-34 °C0.28 lbInfininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated28 W30 Nm3 lb-ft210 bar+250 °FProportional Flow Control/Regulator100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC ANormally Open, Pressure Compensated36 L/min780 @ 3000 PSI (210 BAR) cm3/min7%36.0 L/min25% of Input Signal13.8 barNitrileElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2150NL
Quote Required
TBD
Electrical, ManualNitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000 psi-30 °F0.28 lbInfininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated28 W30 Nm3 lb-ft210 bar+121 °CProportional Flow Control/Regulator100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC ANormally Open, Pressure Compensated36 L/min780 @ 3000 PSI (210 BAR) cm3/min7%36.0 L/min25% of Input Signal200 psiNitrileElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2150V
Quote Required
TBD
Electrical, ManualFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28Infininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2150VL
Quote Required
TBD
Electrical, ManualFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28Infininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4NoN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2151N
Quote Required
TBD
Electrical, ManualNitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)210 bar-30 °F0.28 lbInfininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated28 W30 Nm4.1 Nm3000 psi+250 °FProportional Flow Control/Regulator100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC ANormally Open, Pressure Compensated36 L/min780 @ 3000 PSI (210 BAR) cm3/min7%9.5 Gal/min25% of Input Signal200 psiNitrileElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2151NL
Quote Required
TBD
Electrical, ManualNitrilen/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-300.28Infininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated282233000+250Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200NitrileElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2151V
Quote Required
TBD
Electrical, ManualFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28Infininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)Up to 20%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated
JP04P2151VL
Quote Required
TBD
Electrical, ManualFluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3000-150.28Infininte Control5/8" Super Coil High Watt (CAP)Solenoid operated, Manually operated282233000+400Proportional Flow Control/Regulator100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4YesN/A3XTop to Side (3 - 2)+/- 7%Max: 2.33 @ 12 VDC, 1.17 @ 24 VDCNormally Open, Pressure Compensated9.5780 @ 3000 PSI (210 BAR)7%9.525% of Input Signal200FluorocarbonElectrical, Manual9.5 GAL/MIN, 36 L/MINNormally Open, Pressure Compensated