- Availability & Price
- Search SKU
Filter by attributes
- Actuation Type
- Configuration
- Flow Rate
- Seal Material
Filter by manufacturer
2 Way Flow Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | UOM | Weight | Coil Nut Tightening Torque | Maximum Kinematic Viscosity | Flow Rate | Actuation Type | Minimum Operating Temperature | Flow Rate Accuracy | Connection Size | For Fluid Type | Frequency | Maximum Operating Temperature | Operating Temperature | Maximum Operating Pressure | Configuration | Variation of Closing Point | Flow Direction | Minimum Pressure Differential | Hysteresis | Override Functionality | Function | Operation Type | Installation Torque | Leak Rate | Filter Efficiency Rating | Maximum Flow Rate | Power Consumption | Coil Type | Current | Variation of Opening Point | Body Material | Connection Type | Cavity Size | Valve Material | Maximum Inlet Pressure Rating | Division | Division | Seal Material | Wire Mesh Screen Included | Seal Material | Actuation Type | Configuration | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DF122C14 | Quote Required | 10 In Stock | $240.75 | EA | 0.7 lb | Finger Tight | 45-2000 SSU (6 to 420 cSt) | 53 L/min | Electrical, Manual | -34 °C | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +250 °F | -30 to +250 °F | 3000 psi | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | Push Type w/Extended Rod | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 21 lb-ft | 250 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 14.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C12-2 | All parts steel. All operating parts hardened steel | 210 bar | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Nitrile | No | Nitrile | Electrical, Manual | Normally Closed | 14 GAL/MIN, 53 L/MIN | |
| DF122C14V | Quote Required | TBD | 0.32 kg | Finger Tight | 45-2000 SSU (6 to 420 cSt) | 14 Gal/min | Electrical, Manual | -15 °F | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +204 °C | -15 to +400 °F | 210 bar | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | Push Type w/Extended Rod | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 21 lb-ft | 250 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 53.0 L/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C12-2 | All parts steel. All operating parts hardened steel | 3000 psi | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical, Manual | Normally Closed | 14 GAL/MIN, 53 L/MIN | |||
| DF122N14 | Quote Required | TBD | 0.32 kg | Finger Tight | 45-2000 SSU (6 to 420 cSt) | 14 Gal/min | Electrical, Manual | -34 °C | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +121 °C | -30 to +250 °F | 3000 psi | Normally Open | N/A | Nose to Side (1 - 2) | N/A psi | 4% | Push Type w/Extended Rod | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 29 Nm | 250 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 14.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | N/A | n/a | n/a | C12-2 | All parts steel. All operating parts hardened steel | 3000 psi | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Nitrile | No | Nitrile | Electrical, Manual | Normally Open | 14 GAL/MIN, 53 L/MIN | |||
| DF122N14V | Quote Required | TBD | 0.7 lb | Finger Tight | 45-2000 SSU (6 to 420 cSt) | 53 L/min | Electrical, Manual | -15 °F | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +400 °F | -26 to +204 °C | 210 bar | Normally Open | N/A | Nose to Side (1 - 2) | N/A psi | 4% | Push Type w/Extended Rod | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 21 lb-ft | 250 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 14.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | N/A | n/a | n/a | C12-2 | All parts steel. All operating parts hardened steel | 3000 psi | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical, Manual | Normally Open | 14 GAL/MIN, 53 L/MIN | |||
| DF161C40 | Quote Required | TBD | 0.75 lb | 4.1 Nm | 45-2000 SSU (6 to 420 cSt) | 40 Gal/min | Electrical | -30 °F | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +121 °C | -30 to +250 °F | 3000 psi | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 54 Nm | 125 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 40.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C16-2 | All parts steel. All operating parts hardened steel | 210 bar | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Nitrile | No | Nitrile | Electrical | Normally Closed | 40 GAL/MIN, 150 L/MIN | |||
| DF161C40V | Quote Required | TBD | 0.75 lb | 4.1 Nm | 45-2000 SSU (6 to 420 cSt) | 150 L/min | Electrical | -15 °F | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +204 °C | -26 to +204 °C | 210 bar | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 40 lb-ft | 125 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 40.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C16-2 | All parts steel. All operating parts hardened steel | 210 bar | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical | Normally Closed | 40 GAL/MIN, 150 L/MIN | |||
| DF201C60 | Quote Required | TBD | 0.75 lb | 3 lb-ft | 45-2000 SSU (6 to 420 cSt) | 60 Gal/min | Electrical | -34 °C | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +121 °C | -34 to +121 °C | 3000 psi | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 83 lb-ft | 125 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 60.0 Gal/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C20-2 | All parts steel. All operating parts hardened steel | 3000 psi | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Nitrile | No | Nitrile | Electrical | Normally Closed | 60 GAL/MIN, 227 L/MIN | |||
| DF201C60V | Quote Required | TBD | 0.34 kg | 3 lb-ft | 45-2000 SSU (6 to 420 cSt) | 60 Gal/min | Electrical | -15 °F | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | +204 °C | -26 to +204 °C | 210 bar | Normally Closed | N/A | Side to Nose (2 - 1) | N/A psi | 4% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 113 Nm | 125 @ 3000 PSI (210 BAR) cm3/min | ISO 4406 18/16/13, SAE Class 4 | 227.0 L/min | 42 W | 1" DS Coil High Watt | Max: 3.53 @ 12 VDC, 1.79 @ 24 VDC A | 20%-30% of Input Signal | n/a | n/a | C20-2 | All parts steel. All operating parts hardened steel | 3000 psi | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical | Normally Closed | 60 GAL/MIN, 227 L/MIN | |||
| DFA125C21SN | Quote Required | TBD | 0.89 | 3 | 45-2000 SSU (6 to 420 cSt) | 15 | Electrical, Manual | -30 | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Closed, Pressure Compensated | N/A | Side to Top (2 - 3) | 300 | < 15% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 55 | 568 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 15.0 | 28 | 5/8" Super Coil High Watt (CAP) | Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC | N/A | n/a | n/a | C12-3L | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical, Manual | Normally Closed, Pressure Compensated | 15 GAL/MIN, 56.8 L/MIN | |||
| DFA125C21SV | Quote Required | TBD | 0.89 | 3 | 45-2000 SSU (6 to 420 cSt) | 15 | Electrical, Manual | -15 | N/A | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +400 | -15 to +400 | 3000 | Normally Closed, Pressure Compensated | N/A | Side to Top (2 - 3) | 300 | < 15% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 55 | 568 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 15.0 | 28 | 5/8" Super Coil High Watt (CAP) | Max: 2.33 @ 12 VDC, 1.17 @ 24 VDC | N/A | n/a | n/a | C12-3L | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical, Manual | Normally Closed, Pressure Compensated | 15 GAL/MIN, 56.8 L/MIN | |||
| HP02C2100N | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical | -30 | Up to 20% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2100NL | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical | -30 | +/- 7% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2100V | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical | -15 | Up to 20% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +400 | -15 to +400 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2100VL | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical | -15 | +/- 7% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +400 | -15 to +400 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2150N | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical, Manual | -30 | Up to 20% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical, Manual | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2150NL | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical, Manual | -30 | +/- 7% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical, Manual | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2150V | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical, Manual | -15 | Up to 20% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +400 | -15 to +400 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical, Manual | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02C2150VL | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 2.5, 3.5, 4, 6 | Electrical, Manual | -15 | +/- 7% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +400 | -15 to +400 | 3000 | Normally Closed, Partially Pressure Compensated | N/A | Bi-directional | N/A | < 10% | Infinite Control | Proportional Flow Control/Regulator | Solenoid operated, Manually operated | 15 | 946 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 2.5, 3.5, 4, 6 | 14, 19 | 1/2" Super Coil | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 25% of Input Signal | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Fluorocarbon | No | Fluorocarbon | Electrical, Manual | Normally Closed, Partially Pressure Compensated | 2.5, 3.5, 4, 6 GAL/MIN, 9.5, 13.3, 15, 22.8 L/MIN | |||
| HP02P2100N | Quote Required | $0.01 | EA | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 4, 5 | Electrical | -30 | Up to 20% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Open, Partially Pressure Compensated | 75% of Input Signal | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 1135 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 4, 5 | 19 | 1/2" Super Coil High Watt (CCP) | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | N/A | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical | Normally Open, Partially Pressure Compensated | 4, 5 GAL/MIN, 15, 19 L/MIN | ||
| HP02P2100NL | Quote Required | TBD | 0.17 | 3 | 45-2000 SSU (6 to 420 cSt) | 4, 5 | Electrical | -30 | +/- 7% | n/a | Mineral-based or synthetic hydraulic fluids | 100-400 | +250 | -30 to +250 | 3000 | Normally Open, Partially Pressure Compensated | 75% of Input Signal | Bi-directional | N/A | < 10% | n/a | Proportional Flow Control/Regulator | Solenoid Operated | 15 | 1135 @ 3000 PSI (210 BAR) | ISO 4406 18/16/13, SAE Class 4 | 4, 5 | 19 | 1/2" Super Coil High Watt (CCP) | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | N/A | n/a | n/a | 2X | All parts steel. All operating parts hardened steel | 3000 | Hydraulic Systems Division | Hydraulic Valve Systems Division | Nitrile | No | Nitrile | Electrical | Normally Open, Partially Pressure Compensated | 4, 5 GAL/MIN, 15, 19 L/MIN |