- Availability & Price
- Search SKU
Filter by attributes
- Actuation Type
- Configuration
- Flow Rate
- Seal Material
Filter by manufacturer
2 Way Flow Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | Variation of Opening Point | Operation Type | Power Consumption | Filter Efficiency Rating | Hysteresis | Valve Material | Flow Direction | Flow Rate Accuracy | Minimum Pressure Differential | Maximum Inlet Pressure Rating | Connection Type | Body Material | Leak Rate | Division | Division | Override Functionality | Flow Rate | Wire Mesh Screen Included | Seal Material | Weight | Maximum Flow Rate | Coil Type | Maximum Kinematic Viscosity | For Fluid Type | Cavity Size | Connection Size | Minimum Operating Temperature | Maximum Operating Pressure | Variation of Closing Point | Operating Temperature | Frequency | Maximum Operating Temperature | Coil Nut Tightening Torque | Installation Torque | Function | Current | Configuration | Actuation Type | Seal Material | Flow Rate | Actuation Type | Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| JP02C2101NL | Quote Required | TBD | 25% of Input Signal | Solenoid Operated | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 200, 300 psi | 210 bar | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 15, 23 L/min | Yes | Nitrile | 0.17 lb | 15, 23 L/min | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -30 °F | 3000 psi | N/A | -34 to +121 °C | 100-400 Hz | +250 °F | 3 lb-ft | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Normally Closed, Pressure Compensated | Electrical | Nitrile | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical | Normally Closed, Pressure Compensated | ||
| JP02C2101V | Quote Required | TBD | 25% of Input Signal | Solenoid Operated | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 13.8, 20.7 bar | 210 bar | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 15, 23 L/min | Yes | Fluorocarbon | 0.17 lb | 15, 23 L/min | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 °F | 3000 psi | N/A | -26 to +204 °C | 100-400 Hz | +400 °F | 4.1 Nm | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Normally Closed, Pressure Compensated | Electrical | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical | Normally Closed, Pressure Compensated | ||
| JP02C2101VL | Quote Required | TBD | 25% of Input Signal | Solenoid Operated | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 13.8, 20.7 bar | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 4, 6 Gal/min | Yes | Fluorocarbon | 0.08 kg | 4, 6 Gal/min | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 °F | 210 bar | N/A | -26 to +204 °C | 100-400 Hz | +400 °F | 4.1 Nm | 20 lb-ft | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Normally Closed, Pressure Compensated | Electrical | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical | Normally Closed, Pressure Compensated | ||
| JP02C2150N | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 13.8, 20.7 bar | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Infinite Control | 4, 6 Gal/min | No | Nitrile | 0.08 kg | 15, 23 L/min | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -34 °C | 3000 psi | N/A | -30 to +250 °F | 100-400 Hz | +121 °C | 4.1 Nm | 20 lb-ft | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Normally Closed, Pressure Compensated | Electrical, Manual | Nitrile | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2150NL | Quote Required | TBD | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Nitrile | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||||||||||||||||||||||||||||||||||||||
| JP02C2150V | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 200, 300 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | Infinite Control | 4, 6 | No | Fluorocarbon | 0.17 | 4, 6 | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | N/A | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | Normally Closed, Pressure Compensated | Electrical, Manual | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2150VL | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 W | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 13.8, 20.7 bar | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Infinite Control | 15, 23 L/min | No | Fluorocarbon | 0.08 kg | 15, 23 L/min | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -26 °C | 210 bar | N/A | -15 to +400 °F | 100-400 Hz | +204 °C | 4.1 Nm | 20 lb-ft | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | Normally Closed, Pressure Compensated | Electrical, Manual | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2151N | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 200, 300 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | Infinite Control | 4, 6 | Yes | Nitrile | 0.17 | 4, 6 | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -30 | 3000 | N/A | -30 to +250 | 100-400 | +250 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | Normally Closed, Pressure Compensated | Electrical, Manual | Nitrile | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2151NL | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 200, 300 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | Infinite Control | 4, 6 | Yes | Nitrile | 0.17 | 4, 6 | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -30 | 3000 | N/A | -30 to +250 | 100-400 | +250 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | Normally Closed, Pressure Compensated | Electrical, Manual | Nitrile | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2151V | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 200, 300 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | Infinite Control | 4, 6 | Yes | Fluorocarbon | 0.17 | 4, 6 | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | N/A | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | Normally Closed, Pressure Compensated | Electrical, Manual | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02C2151VL | Quote Required | TBD | 25% of Input Signal | Solenoid operated, Manually operated | 14, 19 | ISO 4406 18/16/13, SAE Class 4 | < 3%, < 10% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 200, 300 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | Infinite Control | 4, 6 | Yes | Fluorocarbon | 0.17 | 4, 6 | 1/2" Super Coil | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | N/A | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | Normally Closed, Pressure Compensated | Electrical, Manual | Fluorocarbon | 4, 6 GAL/MIN, 15, 23 L/MIN | Electrical, Manual | Normally Closed, Pressure Compensated | ||
| JP02P2000N | Quote Required | TBD | N/A | Solenoid Operated | 14 W | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 10.3 bar | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 9.5 L/min | No | Nitrile | 0.08 kg | 2.5 Gal/min | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -34 °C | 3000 psi | 75% of Input Signal | -30 to +250 °F | 100-400 Hz | +121 °C | 4.1 Nm | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | Normally Open, Pressure Compensated | Electrical | Nitrile | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2000NL | Quote Required | TBD | N/A | Solenoid Operated | 14 W | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 150 psi | 210 bar | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 9.5 L/min | No | Nitrile | 0.08 kg | 2.5 Gal/min | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -34 °C | 3000 psi | 75% of Input Signal | -30 to +250 °F | 100-400 Hz | +250 °F | 4.1 Nm | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | Normally Open, Pressure Compensated | Electrical | Nitrile | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2000V | Quote Required | TBD | N/A | Solenoid Operated | 14 | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 150 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | n/a | 2.5 | No | Fluorocarbon | 0.17 | 2.5 | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | 75% of Input Signal | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | Normally Open, Pressure Compensated | Electrical | Fluorocarbon | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2000VL | Quote Required | TBD | N/A | Solenoid Operated | 14 W | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 10.3 bar | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 9.5 L/min | No | Fluorocarbon | 0.17 lb | 2.5 Gal/min | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 °F | 210 bar | 75% of Input Signal | -26 to +204 °C | 100-400 Hz | +204 °C | 4.1 Nm | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | Normally Open, Pressure Compensated | Electrical | Fluorocarbon | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2001N | Quote Required | TBD | N/A | Solenoid Operated | 14 W | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 150 psi | 3000 psi | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | n/a | 2.5 Gal/min | Yes | Nitrile | 0.08 kg | 9.5 L/min | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -30 °F | 210 bar | 75% of Input Signal | -30 to +250 °F | 100-400 Hz | +121 °C | 3 lb-ft | 27 Nm | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | Normally Open, Pressure Compensated | Electrical | Nitrile | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2001NL | Quote Required | TBD | N/A | Solenoid Operated | 14 | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 150 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | n/a | 2.5 | Yes | Nitrile | 0.17 | 2.5 | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -30 | 3000 | 75% of Input Signal | -30 to +250 | 100-400 | +250 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | Normally Open, Pressure Compensated | Electrical | Nitrile | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2001V | Quote Required | TBD | N/A | Solenoid Operated | 14 | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 150 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | n/a | 2.5 | Yes | Fluorocarbon | 0.17 | 2.5 | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | 75% of Input Signal | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | Normally Open, Pressure Compensated | Electrical | Fluorocarbon | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2001VL | Quote Required | TBD | N/A | Solenoid Operated | 14 | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | +/- 7% | 150 | 3000 | n/a | n/a | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | Hydraulic Valve Systems Division | n/a | 2.5 | Yes | Fluorocarbon | 0.17 | 2.5 | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -15 | 3000 | 75% of Input Signal | -15 to +400 | 100-400 | +400 | 3 | 20 | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | Normally Open, Pressure Compensated | Electrical | Fluorocarbon | 2.5 GAL/MIN, 9.5 L/MIN | Electrical | Normally Open, Pressure Compensated | ||
| JP02P2050N | Quote Required | TBD | N/A | Solenoid operated, Manually operated | 14 W | ISO 4406 18/16/13, SAE Class 4 | < 3% | All parts steel. All operating parts hardened steel | Top to Side (3 - 2) | Up to 20% | 10.3 bar | 210 bar | n/a | n/a | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | Infinite Control | 9.5 L/min | No | Nitrile | 0.08 kg | 2.5 Gal/min | 1/2" Super Coil Low Watt (CCS) | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | -34 °C | 210 bar | 75% of Input Signal | -34 to +121 °C | 100-400 Hz | +250 °F | 4.1 Nm | 20 lb-ft | Proportional Flow Control/Regulator | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | Normally Open, Pressure Compensated | Electrical, Manual | Nitrile | 2.5 GAL/MIN, 9.5 L/MIN | Electrical, Manual | Normally Open, Pressure Compensated |