• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Rate
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

2 Way Flow Control Proportional Valves

Picture for category 2 Way Flow Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMFlow RateMaximum Kinematic ViscosityCoil Nut Tightening TorqueFor Fluid TypeCavity SizeConnection SizePower ConsumptionCoil TypeFrequencyMaximum Operating TemperatureMinimum Operating TemperatureOperating TemperatureFunctionMaximum Operating PressureInstallation TorqueVariation of Closing PointConfigurationActuation TypeHysteresisVariation of Opening PointOperation TypeFilter Efficiency RatingCurrentConnection TypeBody MaterialValve MaterialDivisionMinimum Pressure DifferentialFlow DirectionFlow Rate AccuracyOverride FunctionalitySeal MaterialMaximum Inlet Pressure RatingMaximum Flow RateLeak RateDivisionWeightWire Mesh Screen IncludedFlow RateSeal MaterialActuation TypeConfiguration
JP02C2000NL
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+250 °F-30 °F-30 to +250 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division150 psiTop to Side (3 - 2)+/- 7%n/aNitrile210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.17 lbNo2 GAL/MIN, 7.5 L/MINNitrileElectricalNormally Closed, Pressure Compensated
JP02C2000V
Quote Required
$282.75
EA7.5 L/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+400 °F-26 °C-26 to +204 °CProportional Flow Control/Regulator210 bar20 lb-ftN/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division10.3 barTop to Side (3 - 2)Up to 20%n/aFluorocarbon210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgNo2 GAL/MIN, 7.5 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2000VL
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)3 lb-ftMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+400 °F-26 °C-15 to +400 °FProportional Flow Control/Regulator3000 psi20 lb-ftN/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division10.3 barTop to Side (3 - 2)+/- 7%n/aFluorocarbon210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgNo2 GAL/MIN, 7.5 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2001N
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+250 °F-34 °C-30 to +250 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division10.3 barTop to Side (3 - 2)Up to 20%n/aNitrile3000 psi7.5 L/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgYes2 GAL/MIN, 7.5 L/MINNitrileElectricalNormally Closed, Pressure Compensated
JP02C2001NL
Quote Required
TBD
2 Gal/min45-2000 SSU (6 to 420 cSt)3 lb-ftMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+250 °F-30 °F-30 to +250 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division10.3 barTop to Side (3 - 2)+/- 7%n/aNitrile210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.17 lbYes2 GAL/MIN, 7.5 L/MINNitrileElectricalNormally Closed, Pressure Compensated
JP02C2001V
Quote Required
TBD
245-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a141/2" Super Coil Low Watt (CCS)100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division150Top to Side (3 - 2)Up to 20%n/aFluorocarbon30002.0570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17Yes2 GAL/MIN, 7.5 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2001VL
Quote Required
TBD
245-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a141/2" Super Coil Low Watt (CCS)100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical< 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division150Top to Side (3 - 2)+/- 7%n/aFluorocarbon30002.0570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17Yes2 GAL/MIN, 7.5 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2050N
Quote Required
TBD
2 Gal/min45-2000 SSU (6 to 420 cSt)3 lb-ftMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+121 °C-30 °F-34 to +121 °CProportional Flow Control/Regulator210 bar27 NmN/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division150 psiTop to Side (3 - 2)Up to 20%Infinite ControlNitrile210 bar7.5 L/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.17 lbNo2 GAL/MIN, 7.5 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP02C2050NL
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)3 lb-ftMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil100-400 Hz+121 °C-30 °F-30 to +250 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division10.3 barTop to Side (3 - 2)+/- 7%Infinite ControlNitrile210 bar7.5 L/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgNo2 GAL/MIN, 7.5 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP02C2050V
Quote Required
TBD
245-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a141/2" Super Coil Low Watt (CCS)100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division150Top to Side (3 - 2)Up to 20%Infinite ControlFluorocarbon30002.0570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17No2 GAL/MIN, 7.5 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP02C2050VL
Quote Required
TBD
245-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a141/2" Super Coil Low Watt (CCS)100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division150Top to Side (3 - 2)+/- 7%Infinite ControlFluorocarbon30002.0570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17No2 GAL/MIN, 7.5 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP02C2051N
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+250 °F-34 °C-30 to +250 °FProportional Flow Control/Regulator210 bar20 lb-ftN/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division150 psiTop to Side (3 - 2)Up to 20%Infinite ControlNitrile3000 psi2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.17 lbYes2 GAL/MIN, 7.5 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP02C2051NL
Quote Required
TBD
7.5 L/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+250 °F-34 °C-30 to +250 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division150 psiTop to Side (3 - 2)+/- 7%Infinite ControlNitrile210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgYes2 GAL/MIN, 7.5 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP02C2051V
Quote Required
TBD
245-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a141/2" Super Coil Low Watt (CCS)100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division150Top to Side (3 - 2)Up to 20%Infinite ControlFluorocarbon30002.0570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17Yes2 GAL/MIN, 7.5 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP02C2051VL
Quote Required
TBD
2 Gal/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14 W1/2" Super Coil Low Watt (CCS)100-400 Hz+400 °F-26 °C-15 to +400 °FProportional Flow Control/Regulator3000 psi27 NmN/ANormally Closed, Pressure CompensatedElectrical, Manual< 10%25% of Input SignalSolenoid operated, Manually operatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division150 psiTop to Side (3 - 2)+/- 7%Infinite ControlFluorocarbon210 bar2.0 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgYes2 GAL/MIN, 7.5 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP02C2100N
Quote Required
TBD
EA4, 6 Gal/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14, 19 W1/2" Super Coil100-400 Hz+250 °F-30 °F-34 to +121 °CProportional Flow Control/Regulator3000 psi20 lb-ftN/ANormally Closed, Pressure CompensatedElectrical< 3%, < 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division200, 300 psiTop to Side (3 - 2)Up to 20%n/aNitrile210 bar4, 6 Gal/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgNo4, 6 GAL/MIN, 15, 23 L/MINNitrileElectricalNormally Closed, Pressure Compensated
JP02C2100NL
Quote Required
TBD
4, 6 Gal/min45-2000 SSU (6 to 420 cSt)4.1 NmMineral-based or synthetic hydraulic fluidsC08-3n/a14, 19 W1/2" Super Coil100-400 Hz+250 °F-34 °C-30 to +250 °FProportional Flow Control/Regulator3000 psi20 lb-ftN/ANormally Closed, Pressure CompensatedElectrical< 3%, < 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division200, 300 psiTop to Side (3 - 2)+/- 7%n/aNitrile210 bar15, 23 L/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.08 kgNo4, 6 GAL/MIN, 15, 23 L/MINNitrileElectricalNormally Closed, Pressure Compensated
JP02C2100V
Quote Required
TBD
4, 645-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a14, 191/2" Super Coil100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical< 3%, < 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division200, 300Top to Side (3 - 2)Up to 20%n/aFluorocarbon30004, 6570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17No4, 6 GAL/MIN, 15, 23 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2100VL
Quote Required
TBD
4, 645-2000 SSU (6 to 420 cSt)3Mineral-based or synthetic hydraulic fluidsC08-3n/a14, 191/2" Super Coil100-400+400-15-15 to +400Proportional Flow Control/Regulator300020N/ANormally Closed, Pressure CompensatedElectrical< 3%, < 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDCn/an/aAll parts steel. All operating parts hardened steelHydraulic Valve Systems Division200, 300Top to Side (3 - 2)+/- 7%n/aFluorocarbon30004, 6570 @ 3000 PSI (210 BAR)Hydraulic Systems Division0.17No4, 6 GAL/MIN, 15, 23 L/MINFluorocarbonElectricalNormally Closed, Pressure Compensated
JP02C2101N
Quote Required
TBD
15, 23 L/min45-2000 SSU (6 to 420 cSt)3 lb-ftMineral-based or synthetic hydraulic fluidsC08-3n/a14, 19 W1/2" Super Coil100-400 Hz+121 °C-34 °C-34 to +121 °CProportional Flow Control/Regulator210 bar27 NmN/ANormally Closed, Pressure CompensatedElectrical< 3%, < 10%25% of Input SignalSolenoid OperatedISO 4406 18/16/13, SAE Class 4Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC An/an/aAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division200, 300 psiTop to Side (3 - 2)Up to 20%n/aNitrile210 bar15, 23 L/min570 @ 3000 PSI (210 BAR) cm3/minHydraulic Systems Division0.17 lbYes4, 6 GAL/MIN, 15, 23 L/MINNitrileElectricalNormally Closed, Pressure Compensated