Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | UOM | Flow Rate | Maximum Kinematic Viscosity | Coil Nut Tightening Torque | For Fluid Type | Cavity Size | Connection Size | Power Consumption | Coil Type | Frequency | Maximum Operating Temperature | Minimum Operating Temperature | Operating Temperature | Function | Maximum Operating Pressure | Installation Torque | Variation of Closing Point | Configuration | Actuation Type | Hysteresis | Variation of Opening Point | Operation Type | Filter Efficiency Rating | Current | Connection Type | Body Material | Valve Material | Division | Minimum Pressure Differential | Flow Direction | Flow Rate Accuracy | Override Functionality | Seal Material | Maximum Inlet Pressure Rating | Maximum Flow Rate | Leak Rate | Division | Weight | Wire Mesh Screen Included | Flow Rate | Seal Material | Actuation Type | Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| JP02C2000NL | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +250 °F | -30 °F | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 150 psi | Top to Side (3 - 2) | +/- 7% | n/a | Nitrile | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.17 lb | No | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2000V | Quote Required | $282.75 | EA | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +400 °F | -26 °C | -26 to +204 °C | Proportional Flow Control/Regulator | 210 bar | 20 lb-ft | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 10.3 bar | Top to Side (3 - 2) | Up to 20% | n/a | Fluorocarbon | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | No | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | ||
| JP02C2000VL | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 3 lb-ft | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +400 °F | -26 °C | -15 to +400 °F | Proportional Flow Control/Regulator | 3000 psi | 20 lb-ft | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 10.3 bar | Top to Side (3 - 2) | +/- 7% | n/a | Fluorocarbon | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | No | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2001N | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +250 °F | -34 °C | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 10.3 bar | Top to Side (3 - 2) | Up to 20% | n/a | Nitrile | 3000 psi | 7.5 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | Yes | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2001NL | Quote Required | TBD | 2 Gal/min | 45-2000 SSU (6 to 420 cSt) | 3 lb-ft | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +250 °F | -30 °F | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 10.3 bar | Top to Side (3 - 2) | +/- 7% | n/a | Nitrile | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.17 lb | Yes | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2001V | Quote Required | TBD | 2 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 | 1/2" Super Coil Low Watt (CCS) | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 150 | Top to Side (3 - 2) | Up to 20% | n/a | Fluorocarbon | 3000 | 2.0 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | Yes | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2001VL | Quote Required | TBD | 2 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 | 1/2" Super Coil Low Watt (CCS) | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical | < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 150 | Top to Side (3 - 2) | +/- 7% | n/a | Fluorocarbon | 3000 | 2.0 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | Yes | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2050N | Quote Required | TBD | 2 Gal/min | 45-2000 SSU (6 to 420 cSt) | 3 lb-ft | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +121 °C | -30 °F | -34 to +121 °C | Proportional Flow Control/Regulator | 210 bar | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 150 psi | Top to Side (3 - 2) | Up to 20% | Infinite Control | Nitrile | 210 bar | 7.5 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.17 lb | No | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2050NL | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 3 lb-ft | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil | 100-400 Hz | +121 °C | -30 °F | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 10.3 bar | Top to Side (3 - 2) | +/- 7% | Infinite Control | Nitrile | 210 bar | 7.5 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | No | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2050V | Quote Required | TBD | 2 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 | 1/2" Super Coil Low Watt (CCS) | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 150 | Top to Side (3 - 2) | Up to 20% | Infinite Control | Fluorocarbon | 3000 | 2.0 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | No | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2050VL | Quote Required | TBD | 2 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 | 1/2" Super Coil Low Watt (CCS) | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 150 | Top to Side (3 - 2) | +/- 7% | Infinite Control | Fluorocarbon | 3000 | 2.0 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | No | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2051N | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +250 °F | -34 °C | -30 to +250 °F | Proportional Flow Control/Regulator | 210 bar | 20 lb-ft | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 150 psi | Top to Side (3 - 2) | Up to 20% | Infinite Control | Nitrile | 3000 psi | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.17 lb | Yes | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2051NL | Quote Required | TBD | 7.5 L/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +250 °F | -34 °C | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 150 psi | Top to Side (3 - 2) | +/- 7% | Infinite Control | Nitrile | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | Yes | 2 GAL/MIN, 7.5 L/MIN | Nitrile | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2051V | Quote Required | TBD | 2 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 | 1/2" Super Coil Low Watt (CCS) | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 150 | Top to Side (3 - 2) | Up to 20% | Infinite Control | Fluorocarbon | 3000 | 2.0 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | Yes | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2051VL | Quote Required | TBD | 2 Gal/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14 W | 1/2" Super Coil Low Watt (CCS) | 100-400 Hz | +400 °F | -26 °C | -15 to +400 °F | Proportional Flow Control/Regulator | 3000 psi | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical, Manual | < 10% | 25% of Input Signal | Solenoid operated, Manually operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 150 psi | Top to Side (3 - 2) | +/- 7% | Infinite Control | Fluorocarbon | 210 bar | 2.0 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | Yes | 2 GAL/MIN, 7.5 L/MIN | Fluorocarbon | Electrical, Manual | Normally Closed, Pressure Compensated | |||
| JP02C2100N | Quote Required | TBD | EA | 4, 6 Gal/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14, 19 W | 1/2" Super Coil | 100-400 Hz | +250 °F | -30 °F | -34 to +121 °C | Proportional Flow Control/Regulator | 3000 psi | 20 lb-ft | N/A | Normally Closed, Pressure Compensated | Electrical | < 3%, < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 200, 300 psi | Top to Side (3 - 2) | Up to 20% | n/a | Nitrile | 210 bar | 4, 6 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | No | 4, 6 GAL/MIN, 15, 23 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated | ||
| JP02C2100NL | Quote Required | TBD | 4, 6 Gal/min | 45-2000 SSU (6 to 420 cSt) | 4.1 Nm | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14, 19 W | 1/2" Super Coil | 100-400 Hz | +250 °F | -34 °C | -30 to +250 °F | Proportional Flow Control/Regulator | 3000 psi | 20 lb-ft | N/A | Normally Closed, Pressure Compensated | Electrical | < 3%, < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 200, 300 psi | Top to Side (3 - 2) | +/- 7% | n/a | Nitrile | 210 bar | 15, 23 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.08 kg | No | 4, 6 GAL/MIN, 15, 23 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2100V | Quote Required | TBD | 4, 6 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14, 19 | 1/2" Super Coil | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical | < 3%, < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 200, 300 | Top to Side (3 - 2) | Up to 20% | n/a | Fluorocarbon | 3000 | 4, 6 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | No | 4, 6 GAL/MIN, 15, 23 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2100VL | Quote Required | TBD | 4, 6 | 45-2000 SSU (6 to 420 cSt) | 3 | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14, 19 | 1/2" Super Coil | 100-400 | +400 | -15 | -15 to +400 | Proportional Flow Control/Regulator | 3000 | 20 | N/A | Normally Closed, Pressure Compensated | Electrical | < 3%, < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Valve Systems Division | 200, 300 | Top to Side (3 - 2) | +/- 7% | n/a | Fluorocarbon | 3000 | 4, 6 | 570 @ 3000 PSI (210 BAR) | Hydraulic Systems Division | 0.17 | No | 4, 6 GAL/MIN, 15, 23 L/MIN | Fluorocarbon | Electrical | Normally Closed, Pressure Compensated | |||
| JP02C2101N | Quote Required | TBD | 15, 23 L/min | 45-2000 SSU (6 to 420 cSt) | 3 lb-ft | Mineral-based or synthetic hydraulic fluids | C08-3 | n/a | 14, 19 W | 1/2" Super Coil | 100-400 Hz | +121 °C | -34 °C | -34 to +121 °C | Proportional Flow Control/Regulator | 210 bar | 27 Nm | N/A | Normally Closed, Pressure Compensated | Electrical | < 3%, < 10% | 25% of Input Signal | Solenoid Operated | ISO 4406 18/16/13, SAE Class 4 | Max: 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | n/a | n/a | All parts steel. All operating parts hardened steel | Hydraulic Cartridge Systems Division | 200, 300 psi | Top to Side (3 - 2) | Up to 20% | n/a | Nitrile | 210 bar | 15, 23 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | Hydraulic Systems Division | 0.17 lb | Yes | 4, 6 GAL/MIN, 15, 23 L/MIN | Nitrile | Electrical | Normally Closed, Pressure Compensated |