- Availability & Price
- Search SKU
Filter by attributes
- Actuation Type
- Configuration
- Flow Rate
- Seal Material
Filter by manufacturer
2 Way Flow Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 2-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through a single line in a normally-open or normally-closed configuration. These valves are capable of handling flows up to 227 lpm (60 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure compensation in both normally-open and normally-closed versions due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable applications that need exact control and do not demand the exact same flow every time a function is operated. Parker’s 2-way flow control proportional valves pair well with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Low hysteresis
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Pressure | Seal Material | Connection Size | Connection Type | Body Material | Division | Division | Maximum Kinematic Viscosity | Minimum Operating Temperature | Weight | Maximum Inlet Pressure Rating | Coil Nut Tightening Torque | Cavity Size | Maximum Flow Rate | Maximum Operating Temperature | Function | Frequency | Actuation Type | For Fluid Type | Operation Type | Valve Material | Operating Temperature | Filter Efficiency Rating | Wire Mesh Screen Included | Variation of Opening Point | Override Functionality | Coil Type | Flow Direction | Installation Torque | Flow Rate Accuracy | Variation of Closing Point | Current | Flow Rate | Leak Rate | Hysteresis | Configuration | Power Consumption | Minimum Pressure Differential | Seal Material | Actuation Type | Flow Rate | Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| JP02P2050NL | Quote Required | TBD | 3000 psi | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | 0.08 kg | 3000 psi | 4.1 Nm | C08-3 | 2.5 Gal/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 27 Nm | +/- 7% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | 2.5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 14 W | 10.3 bar | Nitrile | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2050V | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 2.5 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 20 | Up to 20% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | 2.5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 14 | 150 | Fluorocarbon | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2050VL | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 2.5 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 20 | +/- 7% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | 2.5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 14 | 150 | Fluorocarbon | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2051N | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | 0.17 lb | 210 bar | 4.1 Nm | C08-3 | 2.5 Gal/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 27 Nm | Up to 20% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | 9.5 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 14 W | 10.3 bar | Nitrile | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2051NL | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | 0.08 kg | 3000 psi | 4.1 Nm | C08-3 | 2.5 Gal/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 20 lb-ft | +/- 7% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC A | 2.5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 14 W | 150 psi | Nitrile | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2051V | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 2.5 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 20 | Up to 20% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | 2.5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 14 | 150 | Fluorocarbon | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2051VL | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 2.5 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | Infinite Control | 1/2" Super Coil Low Watt (CCS) | Top to Side (3 - 2) | 20 | +/- 7% | 75% of Input Signal | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | 2.5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 14 | 150 | Fluorocarbon | Electrical, Manual | 2.5 GAL/MIN, 9.5 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2100N | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | 0.17 lb | 3000 psi | 3 lb-ft | C08-3 | 19.0 L/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | No | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 lb-ft | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 20.7 bar | Nitrile | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2100NL | Quote Required | TBD | 3000 psi | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | 0.17 lb | 210 bar | 3 lb-ft | C08-3 | 5.0 Gal/min | +121 °C | Proportional Flow Control/Regulator | 100-400 Hz | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | No | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 27 Nm | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 300 psi | Nitrile | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2100V | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | No | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Fluorocarbon | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2100VL | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | No | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Fluorocarbon | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2101N | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | 0.17 lb | 210 bar | 4.1 Nm | C08-3 | 19.0 L/min | +121 °C | Proportional Flow Control/Regulator | 100-400 Hz | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 lb-ft | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 20.7 bar | Nitrile | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2101NL | Quote Required | TBD | 3000 | Nitrile | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +250 | Proportional Flow Control/Regulator | 100-400 | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Nitrile | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2101V | Quote Required | TBD | 210 bar | Fluorocarbon | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 °F | 0.17 lb | 3000 psi | 3 lb-ft | C08-3 | 19.0 L/min | +204 °C | Proportional Flow Control/Regulator | 100-400 Hz | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 27 Nm | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 19 L/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 300 psi | Fluorocarbon | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2101VL | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical | Mineral-based or synthetic hydraulic fluids | Solenoid Operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | n/a | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Fluorocarbon | Electrical | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2150N | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | 0.08 kg | 210 bar | 4.1 Nm | C08-3 | 19.0 L/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 lb-ft | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 20.7 bar | Nitrile | Electrical, Manual | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2150NL | Quote Required | TBD | 210 bar | Nitrile | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | 0.08 kg | 210 bar | 4.1 Nm | C08-3 | 5.0 Gal/min | +250 °F | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 lb-ft | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 20.7 bar | Nitrile | Electrical, Manual | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2150V | Quote Required | TBD | 3000 | Fluorocarbon | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +400 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Fluorocarbon | Electrical, Manual | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2150VL | Quote Required | TBD | 3000 psi | Fluorocarbon | n/a | n/a | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -26 °C | 0.08 kg | 3000 psi | 4.1 Nm | C08-3 | 5.0 Gal/min | +204 °C | Proportional Flow Control/Regulator | 100-400 Hz | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | No | N/A | Infinite Control | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 lb-ft | +/- 7% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC A | 5 Gal/min | 570 @ 3000 PSI (210 BAR) cm3/min | < 3% | Normally Open, Pressure Compensated | 19 W | 20.7 bar | Fluorocarbon | Electrical, Manual | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated | ||
| JP02P2151N | Quote Required | TBD | 3000 | Nitrile | n/a | n/a | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 | 0.17 | 3000 | 3 | C08-3 | 5.0 | +250 | Proportional Flow Control/Regulator | 100-400 | Electrical, Manual | Mineral-based or synthetic hydraulic fluids | Solenoid operated, Manually operated | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Yes | N/A | Infinite Control | 1/2" Super Coil High Watt (CCP) | Top to Side (3 - 2) | 20 | Up to 20% | 75% of Input Signal | Max: 1.58 @ 12 VDC, 0.79 @ 24 VDC | 5 | 570 @ 3000 PSI (210 BAR) | < 3% | Normally Open, Pressure Compensated | 19 | 300 | Nitrile | Electrical, Manual | 5 GAL/MIN, 19 L/MIN | Normally Open, Pressure Compensated |