| Maximum Flow Rate | 2.0 | Leak Rate | 570 @ 3000 PSI (210 BAR) |
| Division | Hydraulic Valve Systems Division | Variation of Closing Point | N/A |
| Function | Proportional Flow Control/Regulator | Operation Type | Solenoid operated, Manually operated |
| Hysteresis | < 10% | Configuration | Normally Closed, Pressure Compensated |
| Weight | 0.17 | Variation of Opening Point | 25% of Input Signal |
| Minimum Pressure Differential | 150 | Power Consumption | 14 |
| Installation Torque | 20 | Coil Nut Tightening Torque | 3 |
| Filter Efficiency Rating | ISO 4406 18/16/13, SAE Class 4 | Valve Material | All parts steel. All operating parts hardened steel |
| Override Functionality | Infinite Control | Flow Direction | Top to Side (3 - 2) |
| Flow Rate Accuracy | +/- 7% | Connection Type | n/a |
| Division | Hydraulic Systems Division | Wire Mesh Screen Included | No |
| Flow Rate | 2 | Operating Temperature | -15 to +400 |
| Body Material | n/a | Frequency | 100-400 |
| Seal Material | Fluorocarbon | For Fluid Type | Mineral-based or synthetic hydraulic fluids |
| Current | Max: 1.15 @ 12 VDC, 0.58 @ 24 VDC | Maximum Inlet Pressure Rating | 3000 |
| Connection Size | n/a | Maximum Kinematic Viscosity | 45-2000 SSU (6 to 420 cSt) |
| Actuation Type | Electrical, Manual | Cavity Size | C08-3 |
| Maximum Operating Temperature | +400 | Maximum Operating Pressure | 3000 |
| Minimum Operating Temperature | -15 | Coil Type | 1/2" Super Coil Low Watt (CCS) |
| Actuation Type | Electrical, Manual | Seal Material | Fluorocarbon |
| Configuration | Normally Closed, Pressure Compensated | Flow Rate | 2 GAL/MIN, 7.5 L/MIN |