• Availability & Price
  • Search SKU
Filter by attributes
  • Cooling Method
  • Design Rating
  • Electrical Requirements
  • Flow Rate
More Filters...
Filter by manufacturer
Manufacturers

StarlettePlus-E (SPS) Series Compressed Air Refrigeration Dryers - 60Hz & UL Listed for North America

Picture for category StarlettePlus-E (SPS) Series Compressed Air Refrigeration Dryers - 60Hz & UL Listed for North America

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air systems inherently suffer from performance and reliability issues, most of which can be directly attributed to water in one form or another. In fact, water accounts for up to 99.9% of the total liquid contamination found in a compressed air system. Therefore, air treatment is essential for manufacturing facilities reliant on compressed air for automation.

For general purpose or non-critical use of compressed air, refrigeration dryers are an ideal choice. Refrigeration dryers utilize a closed loop cooling system to lower the temperature of the compressed air to just above freezing, causing condensation of water vapor.

Most of the condensed liquid is then removed by an integral water separator and drained away. Prior to leaving the dryer, the compressed air is re-heated by the incoming compressed air to prevent condensation on the outside of the downstream distribution piping.

Refrigeration dryers should always be installed with general purpose and high efficiency coalescing filters and are an effective way to reduce water vapor, liquid water and water aerosols for general purpose compressed air applications.

Parker’s StarlettePlus-E (SPS) Series Series dryers are the most environmentally friendly refrigeration dryers available. Designed to work with low Global Warming Potential (GWP) refrigerant, R513A, SPS complies with the requirements of the United States Environmental Protection Agency SNAP Rules 20 & 21 and European F-Gas Regulation (EU 517/2014). This makes Parker PSE the best choice to protect your investment, the climate and the environment.

• Parker StarlettePlus-E refrigeration dryers are developed around a state-of-theart aluminium heat exchanger (E-Pack)

• The E-Pack heat exchanger has a large air/air heat exchanger to pre-cool the incoming compressed air and reduce energy consumption

• The highly effi cient E-Pack design results in a refrigerant circuit with lower absorbed power and uses a smaller volume of refrigerant than other comparable dryers

• The E-Pack design utilizes low pressure drop, cross fl ow heat exchangers to reduce operational costs

• The E-pack heat exchanger includes a high efficiency stainless steel demister separator for liquid removal

• Environmentally friendly, low Global Warming Potential (GWP) refrigerant gas, R513A, on all units.

• All models are equipped as standard with a digital controller that provides an indication of compressed air temperature, volt free alarm contact, service reminder and integral timed drain control

• Optional Energy Saving (ES) models (SPS075 – SPS0250) saves energy by matching power consumption to compressed air demand. The ES models adjust to partial load conditions by allowing the refrigerant compressor to cycle off.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceWidthWeightMaximum Ambient TemperatureHeightMinimum Operating PressureMaximum Operating PressureProduct TypePort ConnectionTechnologyElectronics TypeConnection TypeIngress Protection RatingOptional AccessoriesPressure Dew PointMaximum Operating TemperatureMinimum Operating TemperatureBrandDivisionDepthRefrigerant TypeCooling MethodFlow RateElectrical RequirementsDesign Rating
SPS0100-A11516016TIU
Quote Required
TBD
400.0 mm46 kg50.0 °C650.0 mm2.0 barg16.0 bargRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C5.0 °CParkerIndustrial Gas Filtration and Generation Division24.8 inchR-513AAir Cooled Condenser100 scfm (169.9 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0100-A23016016TIU
Quote Required
TBD
15.7 inch101 lb50.0 °C650.0 mm29.0 psig16.0 bargRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water149.0 °F41.0 °FParkerIndustrial Gas Filtration and Generation Division24.8 inchR-513AAir Cooled Condenser100 scfm (169.9 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS010-A11516016TIU
Quote Required
TBD
300.0 mm24 kg50.0 °C520.0 mm2.0 barg232.0 psigRefrigeration1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5149.0 °F5.0 °CParkerIndustrial Gas Filtration and Generation Division15.7 inchR-513AAir Cooled Condenser10 scfm (17 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0125-A11516016TIU
Quote Required
TBD
15.7 inch47 kg50.0 °C650.0 mm2.0 barg16.0 bargRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C5.0 °CParkerIndustrial Gas Filtration and Generation Division630.0 mmR-513AAir Cooled Condenser125 scfm (212.4 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0125-A23016016TIU
Quote Required
TBD
400.0 mm47 kg122.0 °F25.6 inch2.0 barg232.0 psigRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water65.0 °C41.0 °FParkerIndustrial Gas Filtration and Generation Division630.0 mmR-513AAir Cooled Condenser125 scfm (212.4 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0150-A11516016TIU
Quote Required
TBD
400.0 mm117 lb50.0 °C25.6 inch2.0 barg16.0 bargRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C5.0 °CParkerIndustrial Gas Filtration and Generation Division24.8 inchR-513AAir Cooled Condenser150 scfm (254.9 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0150-A23016016TIU
Quote Required
TBD
15.7 inch53 kg50.0 °C25.6 inch2.0 barg16.0 bargRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water149.0 °F5.0 °CParkerIndustrial Gas Filtration and Generation Division24.8 inchR-513AAir Cooled Condenser150 scfm (254.9 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS015-A11516016TIU
Quote Required
TBD
300.0 mm53 lb50.0 °C20.5 inch2.0 barg16.0 bargRefrigeration1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C5.0 °CParkerIndustrial Gas Filtration and Generation Division400.0 mmR-513AAir Cooled Condenser15 scfm (25.5 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0175-A11516016TIU
Quote Required
TBD
400.0 mm55 kg50.0 °C25.6 inch29.0 psig232.0 psigRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C41.0 °FParkerIndustrial Gas Filtration and Generation Division630.0 mmR-513AAir Cooled Condenser175 scfm (297.3 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0175-A23016016TIU
Quote Required
TBD
15.7 inch55 kg122.0 °F25.6 inch2.0 barg16.0 bargRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water149.0 °F5.0 °CParkerIndustrial Gas Filtration and Generation Division630.0 mmR-513AAir Cooled Condenser175 scfm (297.3 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0200-A23016014TIU
Quote Required
TBD
17.7 inch80 kg50.0 °C33.1 inch29.0 psig203.0 psigRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C41.0 °FParkerIndustrial Gas Filtration and Generation Division780.0 mmR-513AAir Cooled Condenser200 scfm (339.8 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS0250-A23016014TIU
Quote Required
TBD
450.0 mm80 kg50.0 °C33.1 inch2.0 barg14.0 bargRefrigeration1 1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5149.0 °F5.0 °CParkerIndustrial Gas Filtration and Generation Division30.7 inchR-513AAir Cooled Condenser250 scfm (424.8 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS025-A11516016TIU
Quote Required
TBD
300.0 mm55 lb50.0 °C20.5 inch2.0 barg232.0 psigRefrigeration1/2 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5149.0 °F41.0 °FParkerIndustrial Gas Filtration and Generation Division400.0 mmR-513AAir Cooled Condenser25 scfm (42.5 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS035-A11516016TIU
Quote Required
TBD
13 inch35 kg50.0 °C580.0 mm29.0 psig16.0 bargRefrigeration3/4 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C41.0 °FParkerIndustrial Gas Filtration and Generation Division21.7 inchR-513AAir Cooled Condenser35 scfm (59.5 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS050-A11516016TIU
Quote Required
TBD
330.0 mm36 kg50.0 °C580.0 mm29.0 psig16.0 bargRefrigeration3/4 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 565.0 °C5.0 °CParkerIndustrial Gas Filtration and Generation Division21.7 inchR-513AAir Cooled Condenser50 scfm (85 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS075-A11516016TIU
Quote Required
TBD
400.0 mm46 kg122.0 °F650.0 mm2.0 barg16.0 bargRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water65.0 °C41.0 °FParkerIndustrial Gas Filtration and Generation Division630.0 mmR-513AAir Cooled Condenser75 scfm (127.4 m3/h)115V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient
SPS075-A23016016TIU
Quote Required
TBD
400.0 mm101 lb50.0 °C650.0 mm29.0 psig16.0 bargRefrigeration1 inNon-CyclingETL ListedNPT-FIP44Dryer OnlyISO 8573-1 Class 5 for Water149.0 °F41.0 °FParkerIndustrial Gas Filtration and Generation Division24.8 inchR-513AAir Cooled Condenser75 scfm (127.4 m3/h)230V / 1Ph / 60Hz100 psig (7 barg) inlet, 100°F (38°C) inlet & 100°F (38°C) ambient