Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Closed 3/8" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMPort SizeDivisionMediaFunctionCoil TypePort TypeValve TypeBody MaterialInput VoltageSeal MaterialActuation TypeOrifice 1 SizeOrifice 2 SizeProduct SeriesNumber of PortsPower ConsumptionFlow Coefficient 1Flow Coefficient 2Coil Specifications MetMaximum Fluid TemperatureMinimum Fluid TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialCoil TypeVoltage (V)Power (Watts)Body MaterialSeal MaterialFlow Factor 1 (Cv)Orifice 1 Size (inch)Maximum Pressure Differential (psi)
06F20C2114BDF4C01
Quote Required
TBD
3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass24/60NBRDirect Acting7/32 inchn/aGold Ring Series216 W (AC)0.72 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24/6016 Watt (AC)BRASSNBR0.727/32100 psi (AC)
06F20C2114BDF4C05
Quote Required
$188.38
EA3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass110/50-120/60NBRDirect Acting7/32 inchn/aGold Ring Series216 W (AC)0.72 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6016 Watt (AC)BRASSNBR0.727/32100 psi (AC)
06F20C2114BDF4C15
Quote Required
TBD
3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass220/50 to 240/60NBRDirect Acting7/32 inchn/aGold Ring Series216 W (AC)0.72 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6016 Watt (AC)BRASSNBR0.727/32100 psi (AC)
06F20C2114BDFPH05
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass110/50-120/60NBRDirect Acting7/32 inchn/aGold Ring Series216 W (AC)0.72 Cvn/aClass F200 °F0 °F100 psi (AC)0 psiDIN Form A, Class F110/50-120/6016 Watt (AC)BRASSNBR0.727/32100 psi (AC)
06F20C2118BDF4C01
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass24/60NBRDirect Acting9/32 inchn/aGold Ring Series216 W (AC)0.85 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24/6016 Watt (AC)BRASSNBR0.859/32100 psi (AC)
06F20C2118BDF4C05
Quote Required
$187.53
EA3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass110/50-120/60NBRDirect Acting9/32 inchn/aGold Ring Series216 W (AC)0.85 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6016 Watt (AC)BRASSNBR0.859/32100 psi (AC)
06F20C2118BDF4C15
Quote Required
TBD
3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass220/50 to 240/60NBRDirect Acting9/32 inchn/aGold Ring Series216 W (AC)0.85 Cvn/aClass F200 °F0 °F100 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6016 Watt (AC)BRASSNBR0.859/32100 psi (AC)
06F20C2118BDFPH05
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass110/50-120/60NBRDirect Acting9/32 inchn/aGold Ring Series216 W (AC)0.85 Cvn/aClass F200 °F0 °F100 psi (AC)0 psiDIN Form A, Class F110/50-120/6016 Watt (AC)BRASSNBR0.859/32100 psi (AC)
06F20C2118BDFPH15
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass220/50 to 240/60NBRDirect Acting9/32 inchn/aGold Ring Series216 W (AC)0.85 Cvn/aClass F200 °F0 °F100 psi (AC)0 psiDIN Form A, Class F220/50-240/6016 Watt (AC)BRASSNBR0.859/32100 psi (AC)
06F20C2120AAF4C01
Quote Required
TBD
3/8Fluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass24/60NBRDirect Acting5/16n/aGold Ring Series26 W (AC)1.1n/aClass F180015 psi (AC)01/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24/606 Watt (AC)BRASSNBR1.15/1615 psi (AC)
06F20C2120AAF4C05
Quote Required
TBD
3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass110/50-120/60NBRDirect Acting5/16 inchn/aGold Ring Series26 W (AC)1.1 Cvn/aClass F180 °F0 °F15 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/606 Watt (AC)BRASSNBR1.15/1615 psi (AC)
06F20C2120AAF4C15
Quote Required
TBD
3/8Fluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass220/50 to 240/60NBRDirect Acting5/16n/aGold Ring Series26 W (AC)1.1n/aClass F180015 psi (AC)01/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/606 Watt (AC)BRASSNBR1.15/1615 psi (AC)
06F20C2120AAFPH05
Quote Required
$189.57
EA3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass110/50-120/60NBRDirect Acting5/16 inchn/aGold Ring Series26 W (AC)1.1 Cvn/aClass F180 °F0 °F15 psi (AC)0 psiDIN Form A, Class F110/50-120/606 Watt (AC)BRASSNBR1.15/1615 psi (AC)
06F22C2140ADF4C15
Quote Required
TBD
3/8Fluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass220/50 to 240/60NBRPilot Operated5/8n/aGold Ring Series216 W (AC)3n/aClass F1750300 psi (AC)51/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6016 Watt (AC)BRASSNBR35/8300 psi (AC)
06F23C6140ACFPH05
Quote Required
TBD
3/8Fluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayStainless Steel 316110/50-120/60NBRHung Diaphragm5/8n/aGold Ring Series211 W (AC)3n/aClass F1800150 psi (AC)0DIN Form A, Class F110/50-120/6011 Watt (AC)316 Stainless CastingNBR35/8150 psi (AC)
06F25C2122CAF4C01
Quote Required
TBD
3/8 inchFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass24/60NBRDiaphragm11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)5 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24/606 Watt (AC)BRASSNBR1.211/32300 psi (AC)
06F25C2122CAF4C05
Quote Required
$208.79
EA3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass110/50-120/60NBRPivoted Edge11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)5 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/606 Watt (AC)BRASSNBR1.211/32300 psi (AC)
06F25C2122CAF4C15
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XNPT2-WayBrass220/50 to 240/60NBRDiaphragm11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)5 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/606 Watt (AC)BRASSNBR1.211/32300 psi (AC)
06F25C2122CAFPH01
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass24/60NBRDiaphragm11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)5 psiDIN Form A, Class F24/606 Watt (AC)BRASSNBR1.211/32300 psi (AC)
06F25C2122CAFPH05
Quote Required
TBD
3/8 inchFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class FNPT2-WayBrass110/50-120/60NBRPivoted Edge11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)5 psiDIN Form A, Class F110/50-120/606 Watt (AC)BRASSNBR1.211/32300 psi (AC)