Parker’s series of 5-way, 2-position pilot operated directional control valves are ideal for very high flow applications with a wide range of pressure capabilities. These valves can be used as diverter or switching valves controlling functions or subsystems on a wide array of machinery within the agriculture, construction, industrial, and oil & gas markets.
The variety of options and reliable performance allows for these valves to be implemented in power units, priority steering, or general high flow pressure compensation applications, and can even be configured to include a transitional state when shifting the valve to divert the flow path. The high flow capacity coupled with pilot operation and an assortment of spring settings means Parker can ensure optimal functionality by providing the best valve for the application dependent on the pilot pressure available.
Markets:
• Agriculture Machinery
• Construction equipment
• Material Handling Equipment
• Oil & Gas
• Vocational & Municipal Equipment
Features/Benefits:
• High flow capacity
• Used as high flow switching or metering element
• Can be configured with transitional states
• Range of spring settings available
• Sealed pilot option available
• All external parts zinc plated
Applications:
• Balers
• Drills
• High flow pressure compensation
• Mixers
• Power units
• Presses
• Priority steering or braking
Additional Technical Insight:
N5 cartridge valves from Parker provide design flexibility for high pressure and high flow applications because they are actually 5-ported cartridges. Each version has 3 work ports, 1 Main pilot port, and one spring chamber vent that can sometimes be used as a second pilot / sense port. Each cartridge contains a spool that is offset by a spring to allow a non-piloted flow configuration. Once pilot pressure is applied to port 1, the spool shifts against the spring creating a second flow configuration. Multiple spool configurations, transition types, and switching pressures are available to cover a wide range of applications. N5A125 and N5A300 cartridge valves have an open transition which connects all 3 work ports together during the shifting of the spool. Both versions operate in the same manner with the key difference being flow rating. The N5A125 is rated for 42 GPM (160 LPM) and the N5A300 is rated for 105 GPM (400 LPM.) They can be used as normally-open, normally-closed and selector directional control valves and in a wide range of pressure and/or flow control circuits. The 5th port spring chamber can be vented to tank or used as a sensing port for applications that require high flow pressure or flow control. N5B125 and N5B300 have the same respective flow ratings and operate in the same manner as the respective N5A125 and N5A300. The key difference is that N5B cartridges have a closed condition transition. Please contact your Parker Application Engineer for assistance selecting the best transition condition for your application. N5C and N5D are similar in their operation to N5A and N5B cartridges but without the transition conditions and with either all work ports blocked or all work ports open. N5C125 and N5C300 cartridges have spools that are spring offset to a condition where all 3 work ports are open. Once pilot pressure is applied to port 1, all 3 work ports are blocked. N5D125 and N5D300 valves are spring offset to an all ports blocked condition. Once pilot pressure is applied, the spool shifts and all ports are connected together. Flow ratings for both size 125 styles is 42 GPM (160 LPM) and the size 300 styles are rated for 105 GPM (400 LPM.)
Read More...The variety of options and reliable performance allows for these valves to be implemented in power units, priority steering, or general high flow pressure compensation applications, and can even be configured to include a transitional state when shifting the valve to divert the flow path. The high flow capacity coupled with pilot operation and an assortment of spring settings means Parker can ensure optimal functionality by providing the best valve for the application dependent on the pilot pressure available.
Markets:
• Agriculture Machinery
• Construction equipment
• Material Handling Equipment
• Oil & Gas
• Vocational & Municipal Equipment
Features/Benefits:
• High flow capacity
• Used as high flow switching or metering element
• Can be configured with transitional states
• Range of spring settings available
• Sealed pilot option available
• All external parts zinc plated
Applications:
• Balers
• Drills
• High flow pressure compensation
• Mixers
• Power units
• Presses
• Priority steering or braking
Additional Technical Insight:
N5 cartridge valves from Parker provide design flexibility for high pressure and high flow applications because they are actually 5-ported cartridges. Each version has 3 work ports, 1 Main pilot port, and one spring chamber vent that can sometimes be used as a second pilot / sense port. Each cartridge contains a spool that is offset by a spring to allow a non-piloted flow configuration. Once pilot pressure is applied to port 1, the spool shifts against the spring creating a second flow configuration. Multiple spool configurations, transition types, and switching pressures are available to cover a wide range of applications. N5A125 and N5A300 cartridge valves have an open transition which connects all 3 work ports together during the shifting of the spool. Both versions operate in the same manner with the key difference being flow rating. The N5A125 is rated for 42 GPM (160 LPM) and the N5A300 is rated for 105 GPM (400 LPM.) They can be used as normally-open, normally-closed and selector directional control valves and in a wide range of pressure and/or flow control circuits. The 5th port spring chamber can be vented to tank or used as a sensing port for applications that require high flow pressure or flow control. N5B125 and N5B300 have the same respective flow ratings and operate in the same manner as the respective N5A125 and N5A300. The key difference is that N5B cartridges have a closed condition transition. Please contact your Parker Application Engineer for assistance selecting the best transition condition for your application. N5C and N5D are similar in their operation to N5A and N5B cartridges but without the transition conditions and with either all work ports blocked or all work ports open. N5C125 and N5C300 cartridges have spools that are spring offset to a condition where all 3 work ports are open. Once pilot pressure is applied to port 1, all 3 work ports are blocked. N5D125 and N5D300 valves are spring offset to an all ports blocked condition. Once pilot pressure is applied, the spool shifts and all ports are connected together. Flow ratings for both size 125 styles is 42 GPM (160 LPM) and the size 300 styles are rated for 105 GPM (400 LPM.)
| Action | Part No. | Availability | Partner Available | Price | Seal Material | Body Material | Minimum Operating Temperature | Flow Rate | Operation Type | Pilot Location | Switching Pressure | Maximum Kinematic Viscosity | Maximum Operating Pressure | Weight | Division | Maximum Inlet Pressure Rating | Maximum Flow Rate | Drain Option | Function | Installation Torque | Configuration | For Fluid Type | Valve Material | Filter Efficiency Rating | Operating Temperature | Maximum Operating Temperature | Cavity Size | Actuation Type | Leak Rate | Flow Direction | Standard Flow Rate Setting | Seal Material | Configuration | Switching Pressure | Flow Rate | Flow Direction | Standard Flow Rate Setting |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N5C125-6.9N | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Pilot Operated | External | 100 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Mobile Hydraulic Systems Division Europe | 6000 | 42 | External | Diverter | 63 | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 | +250 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 21 | Nitrile | Normally Open | 100 PSI, 6.9 BAR | 42 GAL/MIN, 160 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5C125-6.9V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 100 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 21 | Fluorocarbon | Normally Open | 100 PSI, 6.9 BAR | 42 GAL/MIN, 160 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5C300-10.0N | Quote Required | TBD | Nitrile | n/a | -34 °C | 105 Gal/min | Pilot Operated | External | 10 bar | 45-2000 SSU (6 to 420 cSt) | 420 bar | 1 kg | Mobile Hydraulic Systems Division Europe | 6000 psi | 105 Gal/min | External | Diverter | 160 Nm | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +250 °F | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) Gal/min | Nitrile | Normally Open | 145 PSI, 10 BAR | 105 GAL/MIN, 400 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) GAL/MIN, 130 (3 to 2), 240 (3 to 4) L/MIN | ||
| N5C300-3.0N | Quote Required | TBD | Nitrile | n/a | -30 °F | 400 L/min | Pilot Operated | External | 44 psi | 45-2000 SSU (6 to 420 cSt) | 420 bar | 2.2 lb | Mobile Hydraulic Systems Division Europe | 420 bar | 105 Gal/min | External | Diverter | 118 lb-ft | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +121 °C | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 130 (3 to 2), 240 (3 to 4) L/min | Nitrile | Normally Open | 44 PSI, 3 BAR | 105 GAL/MIN, 400 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) GAL/MIN, 130 (3 to 2), 240 (3 to 4) L/MIN | ||
| N5C300-6.9N | Quote Required | TBD | Nitrile | n/a | -34 °C | 105 Gal/min | Pilot Operated | External | 6.9 bar | 45-2000 SSU (6 to 420 cSt) | 6000 psi | 1 kg | Mobile Hydraulic Systems Division Europe | 6000 psi | 400 L/min | External | Diverter | 160 Nm | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -34 to +121 °C | +121 °C | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 130 (3 to 2), 240 (3 to 4) L/min | Nitrile | Normally Open | 100 PSI, 6.9 BAR | 105 GAL/MIN, 400 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) GAL/MIN, 130 (3 to 2), 240 (3 to 4) L/MIN | ||
| N5C300-6.9V | Quote Required | TBD | Fluorocarbon | n/a | -15 °F | 105 Gal/min | Pilot Operated | External | 100 psi | 45-2000 SSU (6 to 420 cSt) | 420 bar | 1 kg | Mobile Hydraulic Systems Division Europe | 6000 psi | 105 Gal/min | External | Diverter | 118 lb-ft | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 °F | +204 °C | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) Gal/min | Fluorocarbon | Normally Open | 100 PSI, 6.9 BAR | 105 GAL/MIN, 400 L/MIN | 2-3-4 Neutral, 2,3,4 Blocked Piloted | 34 (3 to 2), 63 (3 to 4) GAL/MIN, 130 (3 to 2), 240 (3 to 4) L/MIN | ||
| N5D125-0.0N | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 | +250 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Nitrile | Normally Closed | 0 PSI, 0 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-0.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Fluorocarbon | Normally Closed | 0 PSI, 0 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-10.0N | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 | +250 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Nitrile | Normally Closed | 145 PSI, 10 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-10.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Fluorocarbon | Normally Closed | 145 PSI, 10 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-15.0N | Quote Required | TBD | Nitrile | n/a | -30 °F | 42 Gal/min | Pilot Operated | External | 0 psi | 45-2000 SSU (6 to 420 cSt) | 6000 psi | 0.76 lb | Hydraulic Systems Division | 6000 psi | 160 L/min | External | Diverter | 63 lb-ft | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +250 °F | 5A | Switching | 275 @ 2900 PSI (200 BAR) cm3/min | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 80 L/min | Nitrile | Normally Closed | 217 PSI, 15 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-15.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Fluorocarbon | Normally Closed | 217 PSI, 15 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-5.0N | Quote Required | TBD | Nitrile | n/a | -30 °F | 160 L/min | Pilot Operated | External | 0 psi | 45-2000 SSU (6 to 420 cSt) | 420 bar | 0.33 kg | Mobile Hydraulic Systems Division Europe | 6000 psi | 160 L/min | External | Diverter | 63 lb-ft | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +250 °F | 5A | Switching | 275 @ 2900 PSI (200 BAR) cm3/min | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 80 L/min | Nitrile | Normally Closed | 73 PSI, 5 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-5.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Fluorocarbon | Normally Closed | 73 PSI, 5 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-6.9N | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 | +250 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Nitrile | Normally Closed | 100 PSI, 6.9 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D125-6.9V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Pilot Operated | External | 0 | 45-2000 SSU (6 to 420 cSt) | 6000 | 0.76 | Hydraulic Systems Division | 6000 | 42 | External | Diverter | 63 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 5A | Switching | 275 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 | Fluorocarbon | Normally Closed | 100 PSI, 6.9 BAR | 42 GAL/MIN, 160 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 21 GAL/MIN, 80 L/MIN | ||
| N5D300-10.0N | Quote Required | TBD | Nitrile | n/a | -34 °C | 400 L/min | Pilot Operated | External | 145 psi | 45-2000 SSU (6 to 420 cSt) | 6000 psi | 1 kg | Mobile Hydraulic Systems Division Europe | 420 bar | 400 L/min | External | Diverter | 118 lb-ft | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +250 °F | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 Gal/min | Nitrile | Normally Closed | 145 PSI, 10 BAR | 105 GAL/MIN, 400 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 GAL/MIN, 200 L/MIN | ||
| N5D300-10.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 105 | Pilot Operated | External | 145 | 45-2000 SSU (6 to 420 cSt) | 6000 | 2.2 | Hydraulic Systems Division | 6000 | 105 | External | Diverter | 118 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 | Fluorocarbon | Normally Closed | 145 PSI, 10 BAR | 105 GAL/MIN, 400 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 GAL/MIN, 200 L/MIN | ||
| N5D300-3.0N | Quote Required | TBD | Nitrile | n/a | -34 °C | 400 L/min | Pilot Operated | External | 10 bar | 45-2000 SSU (6 to 420 cSt) | 420 bar | 1 kg | Hydraulic Systems Division | 6000 psi | 105 Gal/min | External | Diverter | 160 Nm | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -30 to +250 °F | +250 °F | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) cm3/min | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 Gal/min | Nitrile | Normally Closed | 44 PSI, 3 BAR | 105 GAL/MIN, 400 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 GAL/MIN, 200 L/MIN | ||
| N5D300-3.0V | Quote Required | TBD | Fluorocarbon | n/a | -15 | 105 | Pilot Operated | External | 145 | 45-2000 SSU (6 to 420 cSt) | 6000 | 2.2 | Hydraulic Systems Division | 6000 | 105 | External | Diverter | 118 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | -15 to +400 | +400 | 100-1 | Switching | 400 @ 2900 PSI (200 BAR) | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 | Fluorocarbon | Normally Closed | 44 PSI, 3 BAR | 105 GAL/MIN, 400 L/MIN | 2,3,4 Blocked Neutral, 2-3-4 Piloted | 53 GAL/MIN, 200 L/MIN |