Parker’s selection of 2-way proportional poppet valves provide exact and reliable controls for applications that require a proportional flow control with a very low leakage rate. These valves are capable of handling flows up to 83 lpm (22 gpm) and pressures as high as 210 bar (3000 psi). The added feature of an integrated pressure compensator make these valves ideal for applications that need controllability at a very high degree of confidence. Parker’s 2-way proportional poppet valves are available in normally-open or normally-closed configurations and can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver. These valves have uses on a variety of machinery within the agriculture, aerial, material handling, or construction markets.
Markets:
• Agriculture
• Aerial
• Construction
• Material Handling
• Miscellaneous Mobile
Features/Benefits:
• Excellent metering capability and control throughout the full flow range
• Reduced drift
• Low leak control (less than 5 dpm)
• Modular solution to applied problem
• Low leak compensator, requiring no additional seals, results in very low hysteresis (< 10%)
• Maintains constant flow regardless of load condition
• Patented integrated low leak compensator
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
• Applications requiring pressure compensation
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Aerial
• Construction
• Material Handling
• Miscellaneous Mobile
Features/Benefits:
• Excellent metering capability and control throughout the full flow range
• Reduced drift
• Low leak control (less than 5 dpm)
• Modular solution to applied problem
• Low leak compensator, requiring no additional seals, results in very low hysteresis (< 10%)
• Maintains constant flow regardless of load condition
• Patented integrated low leak compensator
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
• Applications requiring pressure compensation
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | Actuation Type | Connection Size | Connection Type | Body Material | Flow Rate | Division | Division | Maximum Kinematic Viscosity | Minimum Operating Temperature | Maximum Operating Temperature | Maximum Operating Pressure | Weight | Maximum Inlet Pressure Rating | Operation Type | Installation Torque | Coil Nut Tightening Torque | Maximum Flow Rate | Frequency | Configuration | For Fluid Type | Valve Material | Filter Efficiency Rating | Leak Rate | Operating Temperature | Seal Material | Function | Cavity Size | Coil Type | Hysteresis | Flow Direction | Power Consumption | Minimum Pressure Differential | Current | Configuration | Maximum Flow Rate | Seal Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FAPC101C | Quote Required | TBD | Electrical | n/a | n/a | n/a | 38 L/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -37 °C | +200 °F | 210 bar | 0.52 lb | 3000 psi | Solenoid Operated | 34 Nm | 4.1 Nm | 38 L/min | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -37 to +93 °C | D-Ring | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | D-Ring | ||
| FAPC101CN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 10 Gal/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | +250 °F | 210 bar | 0.24 kg | 3000 psi | Solenoid Operated | 25 lb-ft | 4.1 Nm | 10 Gal/min | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -34 to +121 °C | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | Nitrile | ||
| FAPC101CV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 10 Gal/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -26 °C | +400 °F | 3000 psi | 0.52 lb | 210 bar | Solenoid Operated | 34 Nm | 3 lb-ft | 38 L/min | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -15 to +400 °F | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | Fluorocarbon | ||
| FAPC101N | Quote Required | TBD | Electrical | n/a | n/a | n/a | 10 Gal/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -37 °C | +93 °C | 3000 psi | 0.24 kg | 210 bar | Solenoid Operated | 25 lb-ft | Finger Tight Nm | 38 L/min | 100-400 Hz | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -35 to +200 °F | D-Ring | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 10 GAL/MIN, 38 L/MIN | D-Ring | ||
| FAPC101NN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 10 Gal/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | +121 °C | 210 bar | 0.52 lb | 210 bar | Solenoid Operated | 34 Nm | Finger Tight Nm | 10 Gal/min | 100-400 Hz | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 10 GAL/MIN, 38 L/MIN | Nitrile | ||
| FAPC101NV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 10 | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | +400 | 3000 | 0.52 | 3000 | Solenoid Operated | 25 | Finger Tight | 10 | 100-400 | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) | -15 to +400 | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | 3X | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 | 500 | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC | Normally Open | 10 GAL/MIN, 38 L/MIN | Fluorocarbon | ||
| FAPC121CN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 57 L/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | +250 °F | 210 bar | 0.79 lb | 3000 psi | Solenoid Operated | 48 Nm | 4.1 Nm | 57 L/min | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | C12-3L | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 15 GAL/MIN, 57 L/MIN | Nitrile | ||
| FAPC121CV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 15 | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | +400 | 3000 | 0.79 | 3000 | Solenoid Operated | 35 | 3 | 15 | 100-400 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) | -15 to +400 | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | C12-3L | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 | 500 | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC | Normally Closed | 15 GAL/MIN, 57 L/MIN | Fluorocarbon | ||
| FAPC121NN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 15 Gal/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | +121 °C | 3000 psi | 0.36 kg | 210 bar | Solenoid Operated | 48 Nm | Finger Tight Nm | 57 L/min | 100-400 Hz | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | C12-3L | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 15 GAL/MIN, 57 L/MIN | Nitrile | ||
| FAPC121NV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 15 | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | +400 | 3000 | 0.79 | 3000 | Solenoid Operated | 35 | Finger Tight | 15 | 100-400 | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) | -15 to +400 | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | C12-3L | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 | 500 | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC | Normally Open | 15 GAL/MIN, 57 L/MIN | Fluorocarbon | ||
| FAPC161CN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 83 L/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | +250 °F | 210 bar | 1.08 lb | 210 bar | Solenoid Operated | 80-85 lb-ft | 3 lb-ft | 83 L/min | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | C16-3 | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 22 GAL/MIN, 83 L/MIN | Nitrile | ||
| FAPC161CV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 22 | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | +400 | 3000 | 1.08 | 3000 | Solenoid Operated | 80-85 | 3 | 22 | 100-400 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) | -15 to +400 | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | C16-3 | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 | 500 | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC | Normally Closed | 22 GAL/MIN, 83 L/MIN | Fluorocarbon | ||
| FAPC161NN | Quote Required | TBD | Electrical | n/a | n/a | n/a | 83 L/min | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | +121 °C | 3000 psi | 1.08 lb | 210 bar | Solenoid Operated | 80-85 lb-ft | Finger Tight Nm | 83 L/min | 100-400 Hz | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -34 to +121 °C | Nitrile | Proportional Pressure Compensated Flow Control/Regulator | C16-3 | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 W | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 22 GAL/MIN, 83 L/MIN | Nitrile | ||
| FAPC161NV | Quote Required | TBD | Electrical | n/a | n/a | n/a | 22 | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | +400 | 3000 | 1.08 | 3000 | Solenoid Operated | 80-85 | Finger Tight | 22 | 100-400 | Normally Open | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) | -15 to +400 | Fluorocarbon | Proportional Pressure Compensated Flow Control/Regulator | C16-3 | 5/8" Super Coil Low Watt (CAS) | < 10% | Top to Side (3 - 2) | 18 | 500 | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC | Normally Open | 22 GAL/MIN, 83 L/MIN | Fluorocarbon |