• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Mechanism
  • Configuration
  • Flow Rate Display Range
  • Maximum Flow Rate
  • Seal Material
  • Standard Flow Rate Setting
More Filters...
Filter by manufacturer
Manufacturers

Pressure Compensated Flow Control Valves

Picture for category Pressure Compensated Flow Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of pressure compensated flow control valves feature a proven design that allows for a reliable and repeatable flow compensation curve throughout a wide pressure range. These valves can operate with hydraulic system flows as high as 56 lpm and pressures up to 420 bar with the option of an integrated adjustable or tuneable reverse free-flow check valve. Parker’s pressure compensated flow control valves are ideal for cylinder or motor control and/or bleed-off applications within a broad range of markets, such as the agriculture, construction, material handling, industrial, and oil & gas markets.

Markets:
• Agriculture
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Minimal flow change with pressure variation
• Reverse flow function
• Hardened working parts for maximum durability
• Tamperproof options available
• All external parts zinc plated

Applications:
• Accumulator bleed-off
• Motor speed control
• Cylinder speed control
• Power units

Additional Technical Insight:
Parker offers a wide range of spool type restrictive pressure compensated flow controls to allow for speed control of motors, cylinders, and rotary actuators. Pressure compensation allows the flow devices to maintain a constant flow even with varying loads and inlet pressures. Tunable and fully adjustable versions are available with screw or knob adjusters that can be made tamper resistant with the addition of an optional cap. FR101 is an adjustable pressure compensated flow regulator which compensates for varying loads and pressures in one direction but in the other direction flow is metered across a fixed orifice but not compensated.  In order to allow pressure compensated flow control in one direction and full free flow in the opposite direction, Parker offers an internal check valve in the adjustable FC101 cartridge.  Because both versions are tunable and not fully adjustable, the valve will need to be specified with the appropriate flow range for the application. Changes in flow rates are achieved by mechanically varying the spring force acting on a spool that has a fixed orifice and metering compensator. J02E2, J04C2, and J04E2 are fully adjustable pressure compensated flow regulators. In the opposite flow direction, those valves only meter through a fixed orifice and do not compensate. In order to achieve fully adjustable pressure compensated flow control while allowing reverse full flow, the FA101 includes an internal check valve to bypass the compensator and metering orifice.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialConnection SizeConnection TypeBody MaterialMinimum Operating TemperatureDivisionDivisionMaximum Kinematic ViscosityWeightMaximum Operating PressureFunctionCavity SizeMaximum Inlet Pressure RatingStandard Flow Rate SettingFor Fluid TypeValve MaterialFlow Rate AccuracyFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureFlow RateMaximum Flow RateConfigurationActuation TypeOperation TypeInstallation TorqueAdjustment MechanismFlow Rate Display RangeSeal MaterialConfigurationMaximum Flow RateAdjustment MechanismFlow Rate Display RangeStandard Flow Rate Setting
FA101D
Quote Required
TBD
EANitrilen/an/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.53000Flow ControlC10-23000n/aMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-30 to +250+2505.55.5Reverse CheckPressure CompensatedManually operated16 (Aluminum), 48 (Steel)Detented Knob0.2-5.5 gal/min This is the regulated flow range (min - max)NitrileReverse Check5.5 GAL/MIN, 20.6 L/MINDetented Knob0.2-5.5 GAL/MIN, 0.75-20.6 L/MINN/A
FA101S
Quote Required
15 In Stock
$148.75/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.23 kg210 barFlow ControlC10-2210 barN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-30 to +250 °F+250 °F5.5 Gal/min5.5 Gal/minReverse CheckPressure CompensatedManually operated22 (Aluminum), 65 (Steel) NmScrew0.2-5.5 Gal/minNitrileReverse Check5.5 GAL/MIN, 20.6 L/MINScrew0.2-5.5 GAL/MIN, 0.75-20.6 L/MINN/A
FA101SV
Quote Required
$161.25/each
EAFluorocarbonn/an/an/a-15 °FHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.5 lb210 barFlow ControlC10-23000 psiN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-15 to +400 °F+400 °F5.5 Gal/min20.6 L/minReverse CheckPressure CompensatedManually operated16 (Aluminum), 48 (Steel) lb-ftScrew0.75-20.6 L/minFluorocarbonReverse Check5.5 GAL/MIN, 20.6 L/MINScrew0.2-5.5 GAL/MIN, 0.75-20.6 L/MINN/A
FC101S100
Quote Required
$180.75/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.23 kg3500 psiFlow ControlC10-23500 psi1 Gal/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-30 to +250 °F+250 °F15 Gal/min15 Gal/minReverse CheckPressure CompensatedManually operated22 NmScrew0.75-2.2 Gal/minNitrileReverse Check15 GAL/MIN, 56 L/MINScrew0.75-2.2 GAL/MIN, 2.8-8.3 L/MIN1 GAL/MIN, 3.8 L/MIN
FC101S300
Quote Required
$172.00/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.5 lb3500 psiFlow ControlC10-23500 psi3 Gal/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °C56 L/min56 L/minReverse CheckPressure CompensatedManually operated16 lb-ftScrew2-4.5 Gal/minNitrileReverse Check15 GAL/MIN, 56 L/MINScrew2-4.5 GAL/MIN, 7.5-16.9 L/MIN3 GAL/MIN, 11.3 L/MIN
FC101S600
Quote Required
$172.00/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.23 kg245 barFlow ControlC10-23500 psi6 Gal/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-35 to +121 °C+250 °F15 Gal/min15 Gal/minReverse CheckPressure CompensatedManually operated22 NmScrew4-8 Gal/minNitrileReverse Check15 GAL/MIN, 56 L/MINScrew4-8 GAL/MIN, 15-30 L/MIN6 GAL/MIN, 22.5 L/MIN
FR101S065
Quote Required
$102.75/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.23 kg3500 psiFlow ControlC10-23500 psiN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel30%ISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °C6 Gal/min6 Gal/minPartial Reverse FlowPressure CompensatedManually operated22 (Aluminum), 65 (Steel) NmScrew1.9-3 L/minNitrilePartial Reverse Flow7 GAL/MIN, 26.5 L/MINScrew0.5-0.8 GAL/MIN, 1.9-3 L/MINN/A
FR101S135
Quote Required
$102.75/each
EANitrilen/an/an/a-30 °FHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.5 lb245 barFlow ControlC10-23500 psiN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel30%ISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °C6 Gal/min22.5 L/minPartial Reverse FlowPressure CompensatedManually operated16 (Aluminum), 48 (Steel) lb-ftScrew4.1-6.4 L/minNitrilePartial Reverse Flow7 GAL/MIN, 26.5 L/MINScrew1.1-1.7 GAL/MIN, 4.1-6.4 L/MINN/A
FR101S185
Quote Required
10 In Stock
$102.75/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.5 lb3500 psiFlow ControlC10-2245 barN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel30%ISO 4406 18/16/13, SAE Class 4-30 to +250 °F+250 °F6 Gal/min6 Gal/minPartial Reverse FlowPressure CompensatedManually operated22 (Aluminum), 65 (Steel) NmScrew6-8.3 L/minNitrilePartial Reverse Flow7 GAL/MIN, 26.5 L/MINScrew1.6-2.2 GAL/MIN, 6-8.3 L/MINN/A
FR101S550
Quote Required
$102.75/each
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)0.5 lb3500 psiFlow ControlC10-2245 barN/A L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel30%ISO 4406 18/16/13, SAE Class 4-35 to +121 °C+250 °F22.5 L/min22.5 L/minPartial Reverse FlowPressure CompensatedManually operated22 (Aluminum), 65 (Steel) NmScrew16.1-25.1 L/minNitrilePartial Reverse Flow7 GAL/MIN, 26.5 L/MINScrew4.3-6.7 GAL/MIN, 16.1-25.1 L/MINN/A
J04E2WN
Quote Required
TBD
EANitrilen/an/an/a-35 °CHydraulic Cartridge Systems DivisionMobile Hydraulic Systems Division Europe45-2000 SSU (6 to 420 cSt)0.2 kg6000 psiFlow ControlC10-2420 bar20 L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-35 to +121 °C+250 °F10.6 Gal/min40 L/minReverse FlowPressure CompensatedManually operated37 lb-ftKnob1-40 L/minNitrileReverse Flow10.6 GAL/MIN, 40 L/MINKnob0.3-10.6 GAL/MIN, 1-40 L/MIN5.3 GAL/MIN, 20 L/MIN
J04E2ZN
Quote Required
3 In Stock
$196.25/each
EANitrilen/an/an/a-30 °FHydraulic Cartridge Systems DivisionMobile Hydraulic Systems Division Europe45-2000 SSU (6 to 420 cSt)0.44 lb420 barFlow ControlC10-2420 bar20 L/minMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/AISO 4406 18/16/13, SAE Class 4-30 to +250 °F+250 °F10.6 Gal/min40 L/minReverse FlowPressure CompensatedManually operated50 NmScrew1-40 L/minNitrileReverse Flow10.6 GAL/MIN, 40 L/MINScrew0.3-10.6 GAL/MIN, 1-40 L/MIN5.3 GAL/MIN, 20 L/MIN