WVM Series Large Flow Low Energy Vacuum Regenerated Compressed Air Dryer
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker Generation 5 WVM compressed air dryers provide an energy efficient heat regenerated compressed air drying solution for large scale compressed air applications. Ideal for electronics and automotive production plants but suitable for all general manufacturing industries where typically high volume flows and low pressure dewpoints are required.
Providing energy savings of up to 25% compared to conventional systems, WVM series compressed air dryers can be equipped with heat exchangers that allow steam or other available process heat sources to be used for heat regeneration. This alternative regeneration process can be employed in addition to or instead of the standard electrical heaters, resulting in even higher energy savings.
Features:
• Constant outlet dewpoint in accordance with ISO8573-1 classes 1, 2 or 3 for water vapour & -40°C PDP (other PDP: -20°C / -70°C on request)
• Full feature electronic control with dewpoint display and Energy Saving Technology fitted as standard
• Large flow capacities
• Active heating under vacuum
• Various options for optimal adaptability to customer needs
• Basic thermal insulation fitted as standard (high performance additional option required for PDP greater than -40°C)
Benefits:
• Low energy costs
• No process air loss
• Regeneration under vacuum further improves energy efficiency
• Low regeneration temperature
WVM series compressed air dryers combine highest quality and reliability with the added peace of mind of being covered by a two year extended warranty scheme*, as well as being backed by a variety of global approvals.
*For details on extended warranty, please see www.polewr.com.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Providing energy savings of up to 25% compared to conventional systems, WVM series compressed air dryers can be equipped with heat exchangers that allow steam or other available process heat sources to be used for heat regeneration. This alternative regeneration process can be employed in addition to or instead of the standard electrical heaters, resulting in even higher energy savings.
Features:
• Constant outlet dewpoint in accordance with ISO8573-1 classes 1, 2 or 3 for water vapour & -40°C PDP (other PDP: -20°C / -70°C on request)
• Full feature electronic control with dewpoint display and Energy Saving Technology fitted as standard
• Large flow capacities
• Active heating under vacuum
• Various options for optimal adaptability to customer needs
• Basic thermal insulation fitted as standard (high performance additional option required for PDP greater than -40°C)
Benefits:
• Low energy costs
• No process air loss
• Regeneration under vacuum further improves energy efficiency
• Low regeneration temperature
WVM series compressed air dryers combine highest quality and reliability with the added peace of mind of being covered by a two year extended warranty scheme*, as well as being backed by a variety of global approvals.
*For details on extended warranty, please see www.polewr.com.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Width | Ambient Temperature | Product Series | Brand | Specifications Met | Noise Level | Operating Temperature | ISO Grade | Technology | Connection Type | Electrical Requirements | Pressure Dew Point | Industry | Operating Pressure | Division | Product Style | Application | Division | Height | Weight | Ingress Protection Rating | Product Type | Depth | Flow Rate | Port Size | Options |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| W125/11VM5-F400CT | Quote Required | TBD | 1692.0 mm | 40.0 °C Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 85 inch | 2977 inch | IP54 Indoor Use Only | Compressed Air Dryer | 56 inch | 1170 m³/h @ 7 barg (689 cfm @ 102 psig) | DN 80 | High Performance Insulation for PDP <-40°C | ||
| W155/11VM5-F400CT | Quote Required | TBD | 67 inch | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 41 to 104 °F | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 4 to 11 barg | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 91 inch | 1460 mm | IP54 Indoor Use Only | Compressed Air Dryer | 1412.0 mm | 1470 m³/h ) @ 7 barg (865 cfm @ 102 psig) | DN 80 | High Performance Insulation for PDP <-40°C | ||
| W210/11VM5-F400CT | Quote Required | TBD | 67 inch | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 41 to 104 °F | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 108 inch | 4123 inch | IP54 Indoor Use Only | Compressed Air Dryer | 56 inch | 2050 m³/h @ 7 barg (1207 cfm @ 102 psig) | DN 80 | High Performance Insulation for PDP <-40°C | ||
| W310/11VM5-F400CT | Quote Required | TBD | 2115.0 mm | 40.0 °C Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 41 to 104 °F | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Standard: -40°C (-40°F)<br/> | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 106 inch | 5755 inch | IP54 Indoor Use Only | Compressed Air Dryer | 1702.0 mm | 3050 m³/h @ 7 barg (1795 cfm @ 102 psig) | DN 100 | High Performance Insulation for PDP <-40°C | ||
| W370/11VM5-F400CT | Quote Required | TBD | 2115.0 mm | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Standard: -40°C (-40°F)<br/> | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 118 inch | 6395 inch | IP54 Indoor Use Only | Compressed Air Dryer | 67 inch | 3700 m³/h @ 7 barg (2178 cfm @ 102 psig) | DN 100 | High Performance Insulation for PDP <-40°C | ||
| W45/11VM5-F400CT | Quote Required | TBD | 1222.0 mm | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 41 to 104 °F | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 4 to 11 barg | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 80 inch | 1698 inch | IP54 Indoor Use Only | Compressed Air Dryer | 48 inch | 450 m³/h @ 7 barg (265 cfm @ 102 psig) | DN 50 | High Performance Insulation for PDP <-40°C | ||
| W520/11VM5-F400CT | Quote Required | TBD | 102 inch | 40.0 °C Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 3210.0 mm | 4275 mm | IP54 Indoor Use Only | Compressed Air Dryer | 1910.0 mm | 5050 m³/h @ 7 barg (2972 cfm @ 102 psig) | DN 150 | High Performance Insulation for PDP <-40°C | ||
| W60/11VM5-F400CT | Quote Required | TBD | 48 inch | 40.0 °C Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 80 inch | 800 mm | IP54 Indoor Use Only | Compressed Air Dryer | 1219.0 mm | 610 m³/h @ 7 barg (359 cfm @ 102 psig) | DN 50 | High Performance Insulation for PDP <-40°C | ||
| W615/11VM5-F400CT | Quote Required | TBD | 102 inch | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 136 inch | 4735 mm | IP54 Indoor Use Only | Compressed Air Dryer | 1910.0 mm | 6050 m³/h @ 7 barg (3561 cfm @ 102 psig) | DN 150 | High Performance Insulation for PDP <-40°C | ||
| W750/11VM5-F400CT | Quote Required | TBD | 110 inch | 104.0 °F Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 41 to 104 °F | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 4 to 11 barg | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 137 inch | 5380 mm | IP54 Indoor Use Only | Compressed Air Dryer | 79 inch | 7300 m³/h @ 7 barg (4297 cfm @ 102 psig) | DN 150 | High Performance Insulation for PDP <-40°C | ||
| W80/11VM5-F400CT | Quote Required | TBD | 48 inch | 40.0 °C Maximum | WVM 5 | Parker | PED 2014/68/EU Fluid Group II | 80 to 85 dBA | 5 to 40 °C | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Filtration | Flanged | Standard: 400V 3ph 50Hz<br/><br/>Options on request. | Options: -70°C (-100°F) or -20°C (-4°F) | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals | 58 to 145 psig | Gas Separation and Filtration Division EMEA | Low Energy - Vacuum Regenerated | Compressed Air Applications | Gas Separation and Filtration Division EMEA | 2379.0 mm | 1985 inch | IP54 Indoor Use Only | Compressed Air Dryer | 1219.0 mm | 800 m³/h @ 7 barg (471 cfm @ 102 psig) | DN 50 | High Performance Insulation for PDP <-40°C |