- Availability & Price
- Search SKU
Filter by attributes
- Adjustment Mechanism
- Holding Pressure
- Maximum Flow Rate
- Mounting Type
- Pilot Pressure Ratio
- Port Size
- Pressure Control Range
- Seal Material
Filter by manufacturer
Standard Pilot Vented Load Control Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
| Action | Part No. | Availability | Partner Available | Price | Port Size | Seal Material | Body Material | Maximum Operating Pressure | Division | Division | Pilot Location | Maximum Kinematic Viscosity | Minimum Operating Temperature | Maximum Inlet Pressure Rating | Flow Rate | Function | Mounting Type | Maximum Operating Temperature | For Fluid Type | Valve Material | Operating Temperature | Filter Efficiency Rating | Actuation Type | Maximum Flow Rate | Weight | Leak Rate | Pilot Pressure Ratio | Pressure Control Sensitivity | Cavity Size | Flow Direction | Holding Pressure | Installation Torque | Adjustment Mechanism | Pressure Control Range | Seal Material | Port Size | Mounting Type | Maximum Flow Rate | Pilot Pressure Ratio | Holding Pressure | Adjustment Mechanism | Pressure Control Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MHC-010-VJNK-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 psi | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -26 °C | 350 bar | 10 Gal/min | Counterbalance Valve | Threaded Cartridge Valve | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 37.5 L/min | 0.38 kg | 5 @ 80% of setting drops/min | 10:1 | N/A bar | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 5000 psi | 50-55 lb-ft | Shimmed (non-adjustable) | N/A psi | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 5000 PSI, 350 BAR | Shimmed (non-adjustable) | N/A | ||
| MHC-010-VJSD-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 1000 | 68-75 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 1000 PSI, 69 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSD-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 1000 | 68-75 | Standard (adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 1000 PSI, 69 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSE-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 1500 | 68-75 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 1500 PSI, 105 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSE-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 1500 | 68-75 | Standard (adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 1500 PSI, 105 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSF-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 2000 | 68-75 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 2000 PSI, 140 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSF-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 psi | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 °F | 350 bar | 10 Gal/min | Counterbalance Valve | Threaded Cartridge Valve | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 Gal/min | 0.38 kg | 5 @ 80% of setting drops/min | 10:1 | N/A bar | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 2000 psi | 50-55 lb-ft | Standard (adjustable) | N/A psi | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 2000 PSI, 140 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSG-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 2500 | 68-75 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 2500 PSI, 170 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSG-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 2500 | 68-75 | Standard (adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 2500 PSI, 170 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSH-00B | Quote Required | TBD | n/a | Nitrile | n/a | 350 bar | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 °F | 5000 psi | 37.5 L/min | Counterbalance Valve | Threaded Cartridge Valve | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 Gal/min | 0.88 lb | 5 @ 80% of setting drops/min | 10:1 | N/A psi | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 210 bar | 50-55 lb-ft | Standard (adjustable) | N/A bar | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 3000 PSI, 210 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSH-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 psi | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -26 °C | 350 bar | 10 Gal/min | Counterbalance Valve | Threaded Cartridge Valve | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 37.5 L/min | 0.88 lb | 5 @ 80% of setting drops/min | 10:1 | N/A psi | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 3000 psi | 50-55 lb-ft | Standard (adjustable) | N/A bar | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 3000 PSI, 210 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSK-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 5000 | 68-75 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 5000 PSI, 350 BAR | Standard (adjustable) | N/A | ||
| MHC-010-VJSK-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 10 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 10 | 0.88 | 5 @ 80% of setting | 10:1 | n/a | CDD-1010 | Cylinder port 2, Valve port 3, Pilot port 1 | 5000 | 68-75 | Standard (adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | 10:1 | 5000 PSI, 350 BAR | Standard (adjustable) | N/A | ||
| MHC-022-VANC-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 1:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 500 | 102-108 | Shimmed (non-adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 1:1 | 500 PSI, 34.5 BAR | Shimmed (non-adjustable) | N/A | ||
| MHC-022-VANC-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 1:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 500 | 102-108 | Shimmed (non-adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 1:1 | 500 PSI, 34.5 BAR | Shimmed (non-adjustable) | N/A | ||
| MHC-022-VASC-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 1:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 500 | 102-108 | Standard (adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 1:1 | 500 PSI, 34.5 BAR | Standard (adjustable) | N/A | ||
| MHC-022-VASC-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 1:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 500 | 102-108 | Standard (adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 1:1 | 500 PSI, 34.5 BAR | Standard (adjustable) | N/A | ||
| MHC-022-VCNE-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -30 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 5:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 1500 | 102-108 | Shimmed (non-adjustable) | n/a | Nitrile | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 5:1 | 1500 PSI, 105 BAR | Shimmed (non-adjustable) | N/A | ||
| MHC-022-VCNE-00F | Quote Required | TBD | n/a | Fluorocarbon | n/a | 5000 | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -15 | 5000 | 25 | Counterbalance Valve | Threaded Cartridge Valve | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 25 | 0.88 | 5 @ 80% of setting | 5:1 | n/a | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 1500 | 102-108 | Shimmed (non-adjustable) | n/a | Fluorocarbon | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 5:1 | 1500 PSI, 105 BAR | Shimmed (non-adjustable) | N/A | ||
| MHC-022-VCNH-00B | Quote Required | TBD | n/a | Nitrile | n/a | 5000 psi | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | -34 °C | 5000 psi | 25 Gal/min | Counterbalance Valve | Threaded Cartridge Valve | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | Pilot Operated, Vented | 93.75 L/min | 0.88 lb | 5 @ 80% of setting drops/min | 5:1 | N/A bar | CDD-1036 | Cylinder port 2, Valve port 3, Pilot port 1 | 3000 psi | 102-108 Nm | Shimmed (non-adjustable) | N/A psi | Nitrile | n/a | Threaded Cartridge Valve | 25 GAL/MIN, 93.75 L/MIN | 5:1 | 3000 PSI, 210 BAR | Shimmed (non-adjustable) | N/A |