Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialPort SizeBody MaterialDivisionPilot LocationMinimum Operating TemperatureMaximum Operating PressureDivisionMaximum Inlet Pressure RatingPort Thread SizeFunctionMaximum Kinematic ViscosityMounting TypeAdjustment MechanismCavity SizeInstallation TorqueMaximum Operating TemperatureFor Fluid TypeValve MaterialOperating TemperatureFilter Efficiency RatingLeak RateFlow DirectionHolding PressurePilot Pressure RatioPressure Control RangeWeightFlow RateActuation TypeMaximum Flow RatePressure Control SensitivitySeal MaterialPort SizeAdjustment MechanismMounting TypeHolding PressurePilot Pressure RatioPressure Control RangeMaximum Flow Rate
E6A060ZN409
Quote Required
23 In Stock
$691.25/each
EANitrilen/an/aHydraulic Cartridge Systems DivisionExternal-30 °F350 barMobile Hydraulic Systems Division Europe5000 psin/aCounterbalance ValveMineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cStThreaded Cartridge ValveScrew Adjustment3C85 Nm+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 46 @ 1450 PSI (100 BAR) drops/minCylinder port 1, Valve port 2, Pilot port 33120 psi8:01725-5000 psi0.53 kg48 Gal/minPilot Operated, Vented180 L/min50 per turn barNitrilen/aScrewThreaded Cartridge Valve3120 PSI, 215 BAR8:1725-5000 PSI, 50-350 BAR48 GAL/MIN, 180 L/MIN
E6B040ZNMK3
Quote Required
$533.00/each
EANitrilen/an/aHydraulic Cartridge Systems DivisionExternal-34 °C5000 psiMobile Hydraulic Systems Division Europe350 barn/aCounterbalance ValveMineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cStThreaded Cartridge ValveScrew68-140 lb-ft+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34° to +121° °CISO 4406:1999 Code 18/16/136 @ 1450 PSI (100 BAR) drops/minCylinder port 1, Valve port 2, Pilot port 3215 bar3:0150-350 bar0.73 lb60 L/minPilot Operated, Vented60 L/min1335 per turn psiNitrilen/aScrewThreaded Cartridge Valve3120 PSI, 215 BAR3:1725-5000 PSI, 50-350 BAR15.9 GAL/MIN, 60 L/MIN
E6B060ZN409
Quote Required
$459.00/each
EANitrilen/an/aHydraulic Cartridge Systems DivisionExternal-34 °C350 barMobile Hydraulic Systems Division Europe350 barn/aCounterbalance Valve45-2000 SSU (6 to 420 cSt)Threaded Cartridge ValveScrew3C63 lb-ft+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34° to +121° °CISO 4406 18/16/13, SAE Class 46 @ 1450 PSI (100 BAR) drops/minCylinder port 1, Valve port 2, Pilot port 3215 bar3:150-350 bar1.17 lb48 Gal/minPilot Operated, Vented180 L/min50 per turn barNitrilen/aScrewThreaded Cartridge Valve3120 PSI, 215 BAR3:1725-5000 PSI, 50-350 BAR48 GAL/MIN, 180 L/MIN