Parker MHC-010-VJSD-00B - Standard Pilot Vented Load Control Valves

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. MHC-010-VJSD-00B
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Flow Rate10Seal MaterialNitrile
Port Sizen/aBody Materialn/a
Minimum Operating Temperature-30Maximum Operating Pressure5000
DivisionHydraulic Valve Systems DivisionDivisionHydraulic Systems Division
Pilot LocationExternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Weight0.88Pressure Control Sensitivityn/a
Maximum Inlet Pressure Rating5000Pressure Control Rangen/a
Maximum Flow Rate10FunctionCounterbalance Valve
Mounting TypeThreaded Cartridge ValveHolding Pressure1000
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Operating Temperature-30 to +250
Maximum Operating Temperature+250Actuation TypePilot Operated, Vented
Leak Rate5 @ 80% of settingPilot Pressure Ratio10:1
Cavity SizeCDD-1010Flow DirectionCylinder port 2, Valve port 3, Pilot port 1
Installation Torque68-75Adjustment MechanismStandard (adjustable)
Seal MaterialNitrilePort Sizen/a
Mounting TypeThreaded Cartridge ValveHolding Pressure1000 PSI, 69 BAR
Maximum Flow Rate10 GAL/MIN, 37.5 L/MINPilot Pressure Ratio10:1
Adjustment MechanismStandard (adjustable)Pressure Control RangeN/A
Product resources