Parker MHC-022-VCNH-00B - Standard Pilot Vented Load Control Valves

Parker’s vented load control valves are designed to operate independent of downstream pressure to prevent runaway loads under all dynamic conditions, handling pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. MHC-022-VCNH-00B
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePort Sizen/a
Body Materialn/aMaximum Operating Pressure5000 psi
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationExternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-34 °CWeight0.88 lb
Flow Rate25 Gal/minMaximum Inlet Pressure Rating5000 psi
FunctionCounterbalance ValveMounting TypeThreaded Cartridge Valve
Holding Pressure3000 psiMaximum Operating Temperature+121 °C
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-34 to +121 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Actuation TypePilot Operated, VentedPilot Pressure Ratio5:1
Leak Rate5 @ 80% of setting drops/minPressure Control SensitivityN/A bar
Flow DirectionCylinder port 2, Valve port 3, Pilot port 1Adjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/A psiCavity SizeCDD-1036
Maximum Flow Rate93.75 L/minInstallation Torque102-108 Nm
Seal MaterialNitrilePort Sizen/a
Mounting TypeThreaded Cartridge ValveHolding Pressure3000 PSI, 210 BAR
Pilot Pressure Ratio5:1Adjustment MechanismShimmed (non-adjustable)
Pressure Control RangeN/AMaximum Flow Rate25 GAL/MIN, 93.75 L/MIN