Parker’s piloted load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open based off a given backpressure specific to the application, which could be much lower than the spring pressure setting. This feature allows predictable and consistent control of a load throughout its lowering cycle.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialActuation TypePort SizeBody MaterialMaximum Operating PressureDivisionDivisionPilot LocationMaximum Kinematic ViscosityMinimum Operating TemperatureWeightMaximum Inlet Pressure RatingFlow RateFunctionMounting TypeHolding PressurePilot Pressure RatioMaximum Operating TemperatureFor Fluid TypeValve MaterialOperating TemperatureFilter Efficiency RatingMaximum Flow RateLeak RatePressure Control SensitivityCavity SizeFlow DirectionInstallation TorqueAdjustment MechanismPressure Control RangeSeal MaterialPort SizeMounting TypeHolding PressureMaximum Flow RateAdjustment MechanismPilot Pressure RatioPressure Control Range
MHC-010-SBSH-00B
Quote Required
$185.25/each
EANitrilePilot Operatedn/an/a5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems DivisionExternal45-2000 SSU (6 to 420 cSt)-34 °C0.88 lb5000 psi10 Gal/minCounterbalance ValveThreaded Cartridge Valve3000 psi4:1+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 437.5 L/min5 @ 80% of setting drops/minN/A psiCDD-1010Cylinder port 2, Valve port 3, Pilot port 168-75 NmStandard (adjustable)N/A psiNitrilen/aThreaded Cartridge Valve3000 PSI, 210 BAR10 GAL/MIN, 37.5 L/MINStandard (adjustable)4:1N/A
MHC-010-SFNE-00B
2 Limited Stock
Quote Required
$216.32/each
EANitrilePilot Operatedn/an/a5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems DivisionExternal45-2000 SSU (6 to 420 cSt)-34 °C0.88 lb5000 psi37.5 L/minCounterbalance ValveThreaded Cartridge Valve1500 psi7:1+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 410 Gal/min5 @ 80% of setting drops/minN/A barCDD-1010Cylinder port 2, Valve port 3, Pilot port 168-75 NmShimmed (non-adjustable)N/A barNitrilen/aThreaded Cartridge Valve1500 PSI, 103.4 BAR10 GAL/MIN, 37.5 L/MINShimmed (non-adjustable)7:1N/A
MHC-022-SJNH-00B
Quote Required
$247.00/each
EANitrilePilot Operatedn/an/a350 barHydraulic Cartridge Systems DivisionHydraulic Systems DivisionExternal45-2000 SSU (6 to 420 cSt)-30 °F0.38 kg5000 psi25 Gal/minCounterbalance ValveThreaded Cartridge Valve210 bar10:1+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 493.75 L/min5 @ 80% of setting drops/minN/A psiCDD-1036Cylinder port 2, Valve port 3, Pilot port 1102-108 NmShimmed (non-adjustable)N/A psiNitrilen/aThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINShimmed (non-adjustable)10:1N/A
MHC-022-SJSH-00F
Quote Required
$285.00/each
EAFluorocarbonPilot Operatedn/an/a350 barHydraulic Cartridge Systems DivisionHydraulic Systems DivisionExternal45-2000 SSU (6 to 420 cSt)-15 °F0.88 lb5000 psi25 Gal/minCounterbalance ValveThreaded Cartridge Valve3000 psi10:1+204 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 493.75 L/min5 @ 80% of setting drops/minN/A barCDD-1036Cylinder port 2, Valve port 3, Pilot port 175-80 lb-ftStandard (adjustable)N/A psiFluorocarbonn/aThreaded Cartridge Valve3000 PSI, 210 BAR25 GAL/MIN, 93.75 L/MINStandard (adjustable)10:1N/A