• Availability & Price
  • Search SKU
Filter by manufacturer
Manufacturers

Series II Standard Mass Flow Controller

Picture for category Series II Standard Mass Flow Controller

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability.  Rated for 8 separate gas types which are customer field adjustable. Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus.  If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller.

Markets:
• Laboratory and Process Instrumentation
• Pharma/Bio-Pharma Equipment
• Air Quality Monitoring System
• Furnace and Coatings

Features/Benefits:
• Fast, Repeatable and Reliable Performance
• Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element
• Easy to integrate into your new or existing systems
• Asset calibration management software included
• Cleaned for analytical use
• Fails shut with Normally Closed Valve for safe operation
• CE, REACH and RoHS II

Applications:
• Gas Control for Laboratory and Process Equipment
• Burner Ratio Control for Ceramics and Metals
• Process and Environmental Analyzers
• Emissions Monitors and Calibrators

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceValve TypeMaximum Operating TemperatureBody MaterialDivisionMinimum Operating TemperatureConnection SizeLeak RateRepeatabilityTurndown RatioWetted MaterialFlow Rate AccuracySpecifications MetElectrical ConnectionTemperature CoefficientConnection TypeFlow RateWarm-Up TimeSeal MaterialSettling TimeSurface FinishControl StabilityPower ConsumptionConnection MaterialAttitude SensitivityPower Supply VoltagePressure CoefficientPressure Control RangeCommunication Interface
601AVQPBD88V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CFace Seal Male20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQPBD99V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °COther20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQPFD00V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CNone20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD22V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD33V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD44V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-1012 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD55V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/2"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD88V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CFace Seal Male20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPFD99V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °COther20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQPGD00V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CNone20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD22V
Quote Required
TBD
Normally Closed70 °C316L Stainless SteelPrecision Fluidics Division-10 °C1/4"Tested < 2 x 10-9 mbar l/s He L/sec< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C °CCompression20 - 75 L/min30 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD33V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD44V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-1012 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD55V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/2"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD88V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CFace Seal Male20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQPGD99V
Quote Required
TBD
Normally Closed70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °COther20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQQAD00V
Quote Required
TBD
Normally Open70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CNone20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQAD22V
Quote Required
TBD
Normally Open70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQAD33V
Quote Required
TBD
Normally Open70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQAD44V
Quote Required
TBD
Normally Open70316L Stainless SteelPrecision Fluidics Division-1012 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CCompression20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc