- Availability & Price
- Search SKU
Series II Standard Mass Flow Controller
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability. Rated for 8 separate gas types which are customer field adjustable. Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus. If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller.
Markets:
• Laboratory and Process Instrumentation
• Pharma/Bio-Pharma Equipment
• Air Quality Monitoring System
• Furnace and Coatings
Features/Benefits:
• Fast, Repeatable and Reliable Performance
• Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element
• Easy to integrate into your new or existing systems
• Asset calibration management software included
• Cleaned for analytical use
• Fails shut with Normally Closed Valve for safe operation
• CE, REACH and RoHS II
Applications:
• Gas Control for Laboratory and Process Equipment
• Burner Ratio Control for Ceramics and Metals
• Process and Environmental Analyzers
• Emissions Monitors and Calibrators
| Action | Part No. | Availability | Partner Available | Price | Surface Finish | Repeatability | Wetted Material | Warm-Up Time | Connection Size | Control Stability | Attitude Sensitivity | Specifications Met | Pressure Coefficient | Electrical Connection | Communication Interface | Seal Material | Valve Type | Power Consumption | Power Supply Voltage | Pressure Control Range | Flow Rate | Division | Maximum Operating Temperature | Body Material | Turndown Ratio | Minimum Operating Temperature | Settling Time | Flow Rate Accuracy | Connection Material | Connection Type | Leak Rate | Temperature Coefficient |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 601CVNSAD88V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 5 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Face Seal Male | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSAD99V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | Other | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 5 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Other | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD00V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | None | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | None | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD11V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/8" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD22V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD33V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 6 mm | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD88V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Face Seal Male | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSBD99V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | Other | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 10 Vdc | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Other | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD00V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | None | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | None | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD11V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/8" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD22V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD33V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 6 mm | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD88V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Face Seal Male | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSFD99V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | Other | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 0 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Other | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD00V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | None | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | None | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD11V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/8" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD22V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD33V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 6 mm | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Compression | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD88V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | 1/4" | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Face Seal Male | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C | ||
| 601CVNSGD99V | Quote Required | TBD | 0.8 µm typical | < 0.2% Reading | 316L Stainless Steel | 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale | Other | < ±0.1% Full Scale (typical for 1 l/min N2) | Max. error at 90° off horizontal 0.2% at 1 ATM, typical N2 | IP40 | 0.1 ATM typical N2; 0.01% / ATM typical H2 | 9-PIN D-CONNECTOR | RS232 + FLOW-BUS 4 to 20 mA Sourcing | Viton (Standard) | Normally Open | Max. 320 mA; Add 50 mA Profibus, if applicable | +15 - 24 Vdc | 928 PSIA | 8 - 25 | Precision Fluidics Division | 70 | 316L Stainless Steel | 1 : 50 (in digital mode up to 1 : 187.5) | -10 | Standard: 2 - 4 seconds | Standard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min) | 316L Stainless Steel | Other | Tested < 2 x 10-9 mbar l/s He | Zero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C |