Parker 601CVNSAD99V - Series II Standard Mass Flow Controller

Our Series II mass flow controllers & meters offer outstanding value in a wide range of applications. Exceptional accuracy for flow ranges from 0.014 sccm to 1,670 slpm, all with optional multi-gas and multi-range capability for maximum flexibility.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 601CVNSAD99V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Pressure Control Range928 PSIAPower ConsumptionMax. 320 mA; Add 50 mA Profibus, if applicable
Power Supply Voltage+15 - 24 VdcFlow Rate8 - 25
Maximum Operating Temperature70DivisionPrecision Fluidics Division
Flow Rate AccuracyStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)Connection SizeOther
Turndown Ratio1 : 50 (in digital mode up to 1 : 187.5)Body Material316L Stainless Steel
Settling TimeStandard: 2 - 4 secondsMinimum Operating Temperature-10
Connection Material316L Stainless SteelLeak RateTested < 2 x 10-9 mbar l/s He
Temperature CoefficientZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °CWarm-Up Time30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale
Attitude SensitivityMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2Wetted Material316L Stainless Steel
Surface Finish0.8 µm typicalRepeatability< 0.2% Reading
Specifications MetIP40Control Stability< ±0.1% Full Scale (typical for 1 l/min N2)
Electrical Connection9-PIN D-CONNECTORCommunication InterfaceRS232 + FLOW-BUS 0 to 5 Vdc
Connection TypeOtherPressure Coefficient0.1 ATM typical N2; 0.01% / ATM typical H2
Seal MaterialViton (Standard)Valve TypeNormally Open
Product resources