• Availability & Price
  • Search SKU
Filter by manufacturer
Manufacturers

Series II Standard Mass Flow Controller

Picture for category Series II Standard Mass Flow Controller

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability.  Rated for 8 separate gas types which are customer field adjustable. Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus.  If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller.

Markets:
• Laboratory and Process Instrumentation
• Pharma/Bio-Pharma Equipment
• Air Quality Monitoring System
• Furnace and Coatings

Features/Benefits:
• Fast, Repeatable and Reliable Performance
• Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element
• Easy to integrate into your new or existing systems
• Asset calibration management software included
• Cleaned for analytical use
• Fails shut with Normally Closed Valve for safe operation
• CE, REACH and RoHS II

Applications:
• Gas Control for Laboratory and Process Equipment
• Burner Ratio Control for Ceramics and Metals
• Process and Environmental Analyzers
• Emissions Monitors and Calibrators

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceValve TypeConnection TypeMaximum Operating TemperatureBody MaterialDivisionMinimum Operating TemperatureConnection SizeLeak RateRepeatabilityTurndown RatioWetted MaterialFlow Rate AccuracySpecifications MetElectrical ConnectionTemperature CoefficientFlow RateWarm-Up TimeSeal MaterialSettling TimeSurface FinishControl StabilityPower ConsumptionConnection MaterialAttitude SensitivityPower Supply VoltagePressure CoefficientPressure Control RangeCommunication Interface
601AVQQAD55V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/2"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQAD88V
Quote Required
TBD
Normally OpenFace Seal Male70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQAD99V
Quote Required
TBD
Normally OpenOther70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 5 Vdc
601AVQQBD00V
Quote Required
TBD
Normally OpenNone70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD22V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD33V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD44V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-1012 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD55V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/2"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD88V
Quote Required
TBD
Normally OpenFace Seal Male70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQBD99V
Quote Required
TBD
Normally OpenOther70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 10 Vdc
601AVQQFD00V
Quote Required
TBD
Normally OpenNone70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD22V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD33V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD44V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-1012 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD55V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/2"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD88V
Quote Required
TBD
Normally OpenFace Seal Male70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQFD99V
Quote Required
TBD
Normally OpenOther70316L Stainless SteelPrecision Fluidics Division-10OtherTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 0 to 20 mA Sourcing
601AVQQGD00V
Quote Required
TBD
Normally OpenNone70316L Stainless SteelPrecision Fluidics Division-10NoneTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQQGD22V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-101/4"Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing
601AVQQGD33V
Quote Required
TBD
Normally OpenCompression70316L Stainless SteelPrecision Fluidics Division-106 mmTested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Profibus - DP 4 to 20 mA Sourcing