- Availability & Price
- Search SKU
- Coil Type
- Flow Factor 1 (Cv)
- Power (Watts)
- Seal Material
- Voltage (V)
Parker 2-Way Normally Closed, 1" NPT General Purpose Solenoid Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's 2-Way Normally Closed 1" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids and gases. These valves are available in brass construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.
Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation
Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff
Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment
| Action | Part No. | Availability | Partner Available | Price | UOM | Port Type | Body Material | Port Size | Division | Media | Function | Valve Type | Input Voltage | Seal Material | Orifice 2 Size | Number of Ports | Flow Coefficient 2 | Coil Specifications Met | Minimum Fluid Temperature | Minimum Pressure Differential | Actuation Type | Power Consumption | Product Series | Coil Type | Orifice 1 Size | Flow Coefficient 1 | Maximum Fluid Temperature | Maximum Pressure Differential | Seal Material | Voltage (V) | Power (Watts) | Coil Type | Flow Factor 1 (Cv) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 7221GBN64E00N0C111P3 | Quote Required | $537.47 | EA | NPT | Brass | 1 inch | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 110/50-120/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 10 W (AC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 inch | 12.5 Cv | 210 °F | 230 psi (AC) | EPDM | 110/50-120/60 | 10 Watt (AC) | 1/2" NPT Conduit, 18" Leads | 12.5 | ||
| 7221GBN64E00N0C111Q3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 220/50 to 240/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 | 11.7 | 210 | 230 psi (AC) | EPDM | 220/50-240/60 | 10 Watt (AC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64E00N0C222P3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 110/50-120/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 | 11.7 | 210 | 230 psi (AC) | EPDM | 110/50-120/60 | 10 Watt (AC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64E00N0C322C1 | Quote Required | TBD | NPT | Brass | 1 inch | Fluid Control Division | Liquids and Gases | Normally Closed (NC) | 2-Way | 12.0 VDC | EPDM | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 22 W (DC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 inch | 11.7 Cv | 210 °F | 85 psi (DC) | EPDM | 12 VDC | 22 Watt (DC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64E00N0C322C2 | Quote Required | TBD | NPT | Brass | 1 inch | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 24.0 VDC | EPDM | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 22 W (DC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 inch | 12.5 Cv | 210 °F | 85 psi (DC) | EPDM | 24 VDC | 22 Watt (DC) | 1/2" NPT Conduit, 18" Leads | 12.5 | |||
| 7221GBN64E00N0D100P3 | Quote Required | TBD | NPT | Brass | 1 inch | Fluid Control Division | Liquids and Gases | Normally Closed (NC) | 2-Way | 110/50-120/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 10 W (AC) | 7000 Series | DIN Form A | 1 inch | 11.7 Cv | 210 °F | 230 psi (AC) | EPDM | 110/50-120/60 | 10 Watt (AC) | DIN Form A | 11.7 | |||
| 7221GBN64E00N0D100Q3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 220/50 to 240/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | DIN Form A | 1 | 11.7 | 210 | 230 psi (AC) | EPDM | 220/50-240/60 | 10 Watt (AC) | DIN Form A | 11.7 | |||
| 7221GBN64E00N0D300C1 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 12.0 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | DIN Form A | 1 | 11.7 | 210 | 85 psi (DC) | EPDM | 12 VDC | 22 Watt (DC) | DIN Form A | 11.7 | |||
| 7221GBN64E00N0D300C2 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 24.0 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | DIN Form A | 1 | 11.7 | 210 | 85 psi (DC) | EPDM | 24 VDC | 22 Watt (DC) | DIN Form A | 11.7 | |||
| 7221GBN64E00N0H111P3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 110/50-120/60 | EPDM | n/a | 2 | n/a | NEMA 9 | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | Hazardous Location Coil | 1 | 2.5 | 210 | 230 psi (AC) | EPDM | 110/50-120/60 | 10 Watt (AC) | Hazardous Location Coil | 2.5 | |||
| 7221GBN64E00N0H222Q3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 220/50 to 240/60 | EPDM | n/a | 2 | n/a | NEMA 9 | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | Hazardous Location Coil | 1 | 11.7 | 210 | 230 psi (AC) | EPDM | 220/50-240/60 | 10 Watt (AC) | Hazardous Location Coil | 11.7 | |||
| 7221GBN64E00N0H322C1 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 12.0 | EPDM | n/a | 2 | n/a | NEMA 9 | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | Hazardous Location Coil | 1 | 11.7 | 210 | 85 psi (DC) | EPDM | 12 VDC | 22 Watt (DC) | Hazardous Location Coil | 11.7 | |||
| 7221GBN64E00N0H322C2 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 24.0 | EPDM | n/a | 2 | n/a | NEMA 9 | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | Hazardous Location Coil | 1 | 11.7 | 210 | 85 psi (DC) | EPDM | 24 VDC | 22 Watt (DC) | Hazardous Location Coil | 11.7 | |||
| 7221GBN64E00N0T100P3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 110/50-120/60 | EPDM | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | Open Frame, 1/4" Tab | 1 | 11.7 | 210 | 230 psi (AC) | EPDM | 110/50-120/60 | 10 Watt (AC) | Open Frame, 1/4" Tab | 11.7 | |||
| 7221GBN64N00N0C111Q3 | Quote Required | TBD | NPT | Brass | 1 inch | Fluid Control Division | Liquids and Gases | Normally Closed (NC) | 2-Way | 220/50 to 240/60 | NBR | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 10 W (AC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 inch | 11.7 Cv | 185 °F | 230 psi (AC) | NBR | 220/50-240/60 | 10 Watt (AC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64N00N0C322C1 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 12.0 | NBR | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 | 11.7 | 210 | 85 psi (DC) | NBR | 12 VDC | 22 Watt (DC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64N00N0C322C2 | Quote Required | $564.27 | EA | NPT | Brass | 1 inch | Fluid Control Division | Liquids and Gases | Normally Closed (NC) | 2-Way | 24.0 VDC | NBR | n/a | 2 | n/a | NEMA 4X | 0 °F | 0 psi | Direct Lift | 22 W (DC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 inch | 11.7 Cv | 185 °F | 85 psi (DC) | NBR | 24 VDC | 22 Watt (DC) | 1/2" NPT Conduit, 18" Leads | 11.7 | ||
| 7221GBN64N00N0C322P3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 110/50-120/60 | NBR | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 22 W (AC) | 7000 Series | 1/2" NPT Conduit, 18" Leads | 1 | 11.7 | 185 | 230 psi (AC) | NBR | 110/50-120/60 | 22 Watt (AC) | 1/2" NPT Conduit, 18" Leads | 11.7 | |||
| 7221GBN64N00N0D100Q3 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 220/50 to 240/60 | NBR | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 10 W (AC) | 7000 Series | DIN Form A | 1 | 11.7 | 210 | 230 psi (AC) | NBR | 220/50-240/60 | 10 Watt (AC) | DIN Form A | 11.7 | |||
| 7221GBN64N00N0D300C1 | Quote Required | TBD | NPT | Brass | 1 | Fluid Control Division | General Purpose for Air | Normally Closed (NC) | 2-Way | 12.0 | NBR | n/a | 2 | n/a | NEMA 4X | 0 | 0 | Direct Lift | 22 W (DC) | 7000 Series | DIN Form A | 1 | 11.7 | 210 | 85 psi (DC) | NBR | 12 VDC | 22 Watt (DC) | DIN Form A | 11.7 |