• Availability & Price
  • Search SKU
Filter by attributes
  • Flow Rate
  • Ratio
  • Seal Material
  • Standard Flow Rate Setting
More Filters...
Filter by manufacturer
Manufacturers

Flow Divider/Combiner Valves

Picture for category Flow Divider/Combiner Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of flow divider/combiner valves feature interlocking spools for pressure compensation in both directions while either dividing or combining the flow. These valves can operate with hydraulic system flows as high as 320 lpm and pressures up to 420 bar with a selection of dividing/combining ratios available. Parker’s divider/combiner valves are ideal for cylinder or motor synchronization applications within a broad range of markets, such as the construction, material handling, industrial markets, oil & gas, and many more.

Markets:
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Interlocking spools for equal control dividing or combining
• Pressure compensated control in both directions
• Hardened, precision ground parts for durability
• Ratios of 50-50, 60-40, and 66-33 available
• All external parts zinc plated

Applications:
• Cylinder synchronization
• Motor synchronization
• Flow partitioning
• Transmission differentials

Additional Technical Insight:
Each of Parker’s four flow divider/combiner versions can be used as a divider or combiner depending on the direction of flow.  Two inter-locking spools allow for pressure compensated flow division and combination to be proportioned based on the selected ratio and flow range.  When port 3 is supplied flow it is divided by a fixed ratio to work ports 2 and 4. For example, if a 50:50 ratio is selected, half of the flow will exit port 2 and the other half will exit port 4. If the actuators have the same area or displacement they will operate at the same speed. If different actuator speeds are required, alternative ratios can be selected to supply different flows to each port. Ratios other than 50:50 can allow speed synchronization of two actuators that have different areas or displacements. The flow to each actuator port is proportional to the inlet flow based on the flow division ratio. When used as a combiner, flow applied to ports 2 and 4 is combined and the total flow exits port 3. The flow from the combiner inlet ports is pressure compensated and the flow ratio determines how much flow is allowed from each port.  Just like the divider mode, the combiner mode allows for actuator speed variation or synchronization. Typical flow accuracy is +/- 10% between ports 2 and 4.  When trying to synchronize 2 cylinders or motors, cross-port relief valves or balancing orifices can be used to help maintain tighter synchronization. Parker’s FDC101, L04A3, L06A3 and L1A300 flow divider/combiners operate in the same manner with each having a different maximum flow and multiple standard ratios and flow ranges.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceFlow RateInstallation TorqueBody MaterialOperating TemperatureMaximum Flow RateMinimum Operating TemperatureDivisionOperation TypeMaximum Kinematic ViscosityConnection SizeWeightValve MaterialMaximum Operating PressureFilter Efficiency RatingFlow Rate AccuracySeal MaterialActuation TypeFor Fluid TypeDivisionConfigurationConnection TypeFunctionMaximum Inlet Pressure RatingStandard Flow Rate SettingRatioCavity SizeMaximum Operating TemperatureSeal MaterialStandard Flow Rate SettingRatioFlow Rate
FDC101A11
Quote Required
16 In Stock
$144.00/each
45 L/min16 lb-ftN/A-34 to +121 °C45 L/min-34 °CHydraulic Systems DivisionAutomatic45-2000 SSU (6 to 420 cSt)N/A0.14 kgAll parts steel. All operating parts hardened steel3500 psiISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner3500 psi1-3 Gal/min50/50C10-4+121 °CNitrile1-3 GAL/MIN, 3.8-11.3 L/MIN50/5012 GAL/MIN, 45 L/MIN
FDC101A33
Quote Required
7 In Stock
$175.75/each
12 Gal/min16 lb-ftN/A-34 to +121 °C45 L/min-30 °FHydraulic Systems DivisionAutomatic45-2000 SSU (6 to 420 cSt)N/A0.3 lbAll parts steel. All operating parts hardened steel3500 psiISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner3500 psi3-6 Gal/min50/50C10-4+121 °CNitrile3-6 GAL/MIN, 11.3-22.5 L/MIN50/5012 GAL/MIN, 45 L/MIN
FDC101A33V
Quote Required
$154.50/each
45 L/min16 lb-ftN/A-15 to +400 °F45 L/min-15 °FHydraulic Systems DivisionAutomatic45-2000 SSU (6 to 420 cSt)N/A0.14 kgAll parts steel. All operating parts hardened steel245 barISO 4406 18/16/13, SAE Class 410%FluorocarbonInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner3500 psi3-6 Gal/min50/50C10-4+400 °FFluorocarbon3-6 GAL/MIN, 11.3-22.5 L/MIN50/5012 GAL/MIN, 45 L/MIN
FDC101A44
Quote Required
$144.00/each
12 Gal/min16 lb-ftN/A-30 to +250 °F45 L/min-30 °FHydraulic Systems DivisionAutomatic45-2000 SSU (6 to 420 cSt)N/A0.14 kgAll parts steel. All operating parts hardened steel245 barISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner245 bar4-8 Gal/min50/50C10-4+121 °CNitrile4-8 GAL/MIN, 15-30 L/MIN50/5012 GAL/MIN, 45 L/MIN
FDC101A66
Quote Required
$144.00/each
45 L/min22 NmN/A-34 to +121 °C45 L/min-30 °FHydraulic Systems DivisionAutomatic45-2000 SSU (6 to 420 cSt)N/A0.3 lbAll parts steel. All operating parts hardened steel245 barISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner245 bar4-8 Gal/min50/50C10-4+250 °FNitrile6-12 GAL/MIN, 22.5-45 L/MIN50/5012 GAL/MIN, 45 L/MIN
L04A3-10-10N
Quote Required
$265.50/each
60 L/min50 NmN/A-34 to +121 °C16 Gal/min-30 °FMobile Hydraulic Systems Division EuropeAutomatic45-2000 SSU (6 to 420 cSt)N/A0.26 lbAll parts steel. All operating parts hardened steel6000 psiISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner6000 psi2.1-5.3 Gal/min50/50C10-4+250 °FNitrile2.1-5.3 GAL/MIN, 8-20 L/MIN50/5016 GAL/MIN, 60 L/MIN
L04A3-25-25N
Quote Required
TBD
60 L/min37 lb-ftN/A-34 to +121 °C16 Gal/min-30 °FMobile Hydraulic Systems Division EuropeAutomatic45-2000 SSU (6 to 420 cSt)N/A0.26 lbAll parts steel. All operating parts hardened steel420 barISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner420 bar13-50 L/min50/50C10-4+250 °FNitrile3.4-13.2 GAL/MIN, 13-50 L/MIN50/5016 GAL/MIN, 60 L/MIN
L04A3-30-30N
Quote Required
11 In Stock
$337.34/each
16 Gal/min37 lb-ftN/A-34 to +121 °C60 L/min-30 °FMobile Hydraulic Systems Division EuropeAutomatic45-2000 SSU (6 to 420 cSt)N/A0.12 kgAll parts steel. All operating parts hardened steel6000 psiISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner420 bar14-60 L/min50/50C10-4+121 °CNitrile3.7-15.9 GAL/MIN, 14-60 L/MIN50/5016 GAL/MIN, 60 L/MIN
L06A3-45-45N
Quote Required
24 In Stock
$665.77/each
47 Gal/min74 lb-ftN/A-30 to +250 °F47 Gal/min-34 °CMobile Hydraulic Systems Division EuropeAutomatic45-2000 SSU (6 to 420 cSt)N/A0.86 lbAll parts steel. All operating parts hardened steel420 barISO 4406 18/16/13, SAE Class 410%NitrileInterlocking SpoolsMineral-based or synthetic hydraulic fluidsHydraulic Cartridge Systems DivisionN/AN/AFlow Divider/Combiner420 bar25-90 L/min50/50C16-4+250 °FNitrile6.6-23.8 GAL/MIN, 25-90 L/MIN50/5047 GAL/MIN, 180 L/MIN