Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMBody MaterialDivisionFlow DirectionMaximum Kinematic ViscosityMinimum Operating TemperatureFunctionMaximum Operating TemperatureMaximum Operating PressureCavity SizeMaximum Inlet Pressure RatingSeal MaterialFlow RateMaximum Flow RateConfigurationActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingWire Mesh Screen IncludedMounting TypeOperating TemperatureLeak RateInput VoltageCoil Nut Tightening TorqueFree Reverse FlowAdjustment MechanismOverride FunctionalityWeightCoil TypeResponse TimeInstallation TorqueConfigurationMaximum Inlet Pressure RatingSeal MaterialActuation TypeWire Mesh Screen IncludedFlow Rate
DSH101NRM
Quote Required
25 In Stock
$129.75/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °F350 barC10-25000 psiD-Ring (Standard)60 L/min60 L/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftYesN/APush Type w/Flush Rod0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NRT
Quote Required
2 Limited Stock
$156.00/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+200 °F350 barC10-2350 barD-Ring (Standard)60 L/min60 L/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/APush and Twist0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NT
Quote Required
$150.75/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °F5000 psiC10-25000 psiD-Ring (Standard)60 L/min60 L/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/APush and Twist0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NTV
Quote Required
$164.00/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C5000 psiC10-2350 barFluorocarbon60 L/min60 L/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-15 to +400 °F5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/APush and Twist0.41 lb5/8" Super Coil70 ms69-75 NmNormally Open5000 PSI, 350 BARFluorocarbonElectrical, ManualNo15 GAL/MIN, 60 L/MIN
DSH101NV
Quote Required
$117.00/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+400 °F5000 psiC10-25000 psiFluorocarbon60 L/min15 Gal/minNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/An/a0.41 lb5/8" Super Coil70 ms51-55 lb-ftNormally Open5000 PSI, 350 BARFluorocarbonElectricalNo15 GAL/MIN, 60 L/MIN
DSH121C
Quote Required
7 In Stock
$159.50/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °C350 barC12-2350 barNitile24 Gal/min24 Gal/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmNoN/An/a0.29 kg5/8" Super Coil100 ms125-131 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CHR
Quote Required
$185.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+250 °F350 barC12-2350 barNitile90 L/min90 L/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftYesN/An/a0.29 kg5/8" Super Coil60 ms125-131 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CHRTV
Quote Required
$239.00/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+400 °F5000 psiC12-25000 psiFluorocarbon24 Gal/min90 L/minNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftYesN/APush and Twist0.29 kg5/8" Super Coil60 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARFluorocarbonElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121CR
Quote Required
15 In Stock
$162.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+250 °F350 barC12-25000 psiNitile90 L/min24 Gal/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/An/a0.65 lb5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CRV
Quote Required
$177.50/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+204 °C5000 psiC12-2350 barFluorocarbon90 L/min90 L/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-15 to +400 °F5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftYesN/An/a0.29 kg5/8" Super Coil100 ms125-131 NmNormally Closed5000 PSI, 350 BARFluorocarbonElectricalNo24 GAL/MIN, 90 L/MIN
DSH121CT
1 Limited Stock
13 In Stock
$204.00/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °C5000 psiC12-2350 barNitile24 Gal/min90 L/minNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/APush and Twist0.65 lb5/8" Super Coil100 ms92-96 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121N
Quote Required
8 In Stock
$201.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °C350 barC12-2350 barNitile90 L/min90 L/minNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmNoN/An/a0.65 lb5/8" Super Coil70 ms92-96 lb-ftNormally Open5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121NR
Quote Required
23 In Stock
$201.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+250 °F5000 psiC12-25000 psiNitrile90 L/min90 L/minNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/An/a0.65 lb5/8" Super Coil70 ms125-131 NmNormally Open5000 PSI, 350 BARNitrileElectricalNo24 GAL/MIN, 90 L/MIN
DSH121NRE
Quote Required
$224.50/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+250 °F350 barC12-2350 barNitrile24 Gal/min90 L/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/APush Type w/Extended Rod0.29 kg5/8" Super Coil70 ms92-96 lb-ftNormally Open5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121NRM
Quote Required
$224.50/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °C350 barC12-2350 barNitrile24 Gal/min24 Gal/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/APush Type w/Flush Rod0.65 lb5/8" Super Coil70 ms92-96 lb-ftNormally Open5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH121NRV
Quote Required
$218.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way+400 °F350 barC12-25000 psiFluorocarbon90 L/min90 L/minNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/An/a0.29 kg5/8" Super Coil70 ms125-131 NmNormally Open5000 PSI, 350 BARFluorocarbonElectricalNo24 GAL/MIN, 90 L/MIN
DSH121NT
Quote Required
$245.50/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+250 °F5000 psiC12-25000 psiNitrile24 Gal/min24 Gal/minNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmNoN/APush and Twist0.29 kg5/8" Super Coil70 ms125-131 NmNormally Open5000 PSI, 350 BARNitrileElectrical, ManualNo24 GAL/MIN, 90 L/MIN
DSH161C
Quote Required
5 In Stock
$130.75/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-30 °F2-Way+250 °F5000 psiC16-25000 psiNitrile150 L/min40 Gal/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/An/a0.34 kg5/8" Super Coil50 ms169-173 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectricalNo40 GAL/MIN, 150 L/MIN
DSH161CH
Quote Required
$138.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °C5000 psiC16-25000 psiNitrile40 Gal/min150 L/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5 drops/min85% of rated voltage at 72°F (20°C) min5-7 lb-ftNoN/An/a0.75 lb5/8" Super Coil40 ms169-173 lb-ftNormally Closed5000 PSI, 350 BARNitrileElectricalNo40 GAL/MIN, 150 L/MIN
DSH161CR
Quote Required
2 Limited Stock
$133.25/each
EAn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-30 °F2-Way+250 °F5000 psiC16-25000 psiNitrile40 Gal/min150 L/minNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F5 drops/min85% of rated voltage at 72°F (20°C) min7-10 NmYesN/An/a0.75 lb5/8" Super Coil50 ms230-235 NmNormally Closed5000 PSI, 350 BARNitrileElectricalNo40 GAL/MIN, 150 L/MIN