Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMActuation TypeBody MaterialMaximum Operating PressureDivisionFlow DirectionMaximum Kinematic ViscosityMinimum Operating TemperatureFunctionMaximum Operating TemperatureOverride FunctionalityMaximum Flow RateCavity SizeFlow RateMaximum Inlet Pressure RatingSeal MaterialOperation TypeWeightConfigurationFor Fluid TypeValve MaterialFilter Efficiency RatingWire Mesh Screen IncludedMounting TypeOperating TemperatureCoil TypeLeak RateInput VoltageResponse TimeInstallation TorqueCoil Nut Tightening TorqueFree Reverse FlowAdjustment MechanismConfigurationFlow RateMaximum Inlet Pressure RatingSeal MaterialActuation TypeWire Mesh Screen Included
DSH081C
Quote Required
11 In Stock
$68.50/each
EAElectricaln/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °Fn/a30 L/minC08-28 Gal/min5000 psiD-Ring (Standard)Solenoid Operated0.25 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftNoN/ANormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CHR
Quote Required
$93.75/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35.0 °F2-Way+93 °Cn/a8 Gal/minC08-28 Gal/min350 barD-Ring (Standard)Solenoid Operated0.11 kgNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms43-49 Nm7-10 NmYesN/ANormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CR
4 In Stock
15 In Stock
$71.50/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35.0 °F2-Way+93 °Cn/a30 L/minC08-28 Gal/min5000 psiD-Ring (Standard)Solenoid Operated0.11 kgNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm7-10 NmYesN/ANormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CTV
Quote Required
$123.50/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way+400 °FPush and Twist8 Gal/minC08-230 L/min5000 psiFluorocarbonSolenoid operated, Manually operated0.25 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftNoN/ANormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH081N
Quote Required
1 Limited Stock
$96.25/each
EAElectricaln/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °Cn/a8 Gal/minC08-28 Gal/min350 barD-Ring (Standard)Solenoid Operated0.25 lbNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm5-7 lb-ftNoN/ANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081NN
Quote Required
$105.75/each
EAElectricaln/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-34 °C2-Way+121 °Cn/a8 Gal/minC08-230 L/min350 barNitrileSolenoid Operated0.25 lbNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-30 to +250 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm7-10 NmNoN/ANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARNitrileElectricalNo
DSH081NR
Quote Required
71 In Stock
$99.00/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °Cn/a8 Gal/minC08-230 L/min350 barD-Ring (Standard)Solenoid Operated0.25 lbNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft7-10 NmYesN/ANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARNitrileElectricalNo
DSH081NRT
Quote Required
16 In Stock
$143.00/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °CPush and Twist8 Gal/minC08-28 Gal/min350 barD-Ring (Standard)Solenoid operated, Manually operated0.11 kgNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm5-7 lb-ftYesN/ANormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH101C
Quote Required
10 In Stock
$72.50/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °Fn/a60 L/minC10-260 L/min5000 psiD-Ring (Standard)Solenoid Operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft7-10 NmNoN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH101CHR
Quote Required
$117.00/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °Cn/a15 Gal/minC10-215 Gal/min350 barD-Ring (Standard)Solenoid Operated0.2 kgNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm7-10 NmYesN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH101CR
Quote Required
54 In Stock
$79.25/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °Cn/a15 Gal/minC10-215 Gal/min350 barD-Ring (Standard)Solenoid Operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft7-10 NmYesN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH101CRT
Quote Required
25 In Stock
$123.50/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way+93 °CPush and Twist60 L/minC10-215 Gal/min350 barD-Ring (Standard)Solenoid operated, Manually operated0.2 kgNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm5-7 lb-ftYesN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH101CRTN
Quote Required
$134.75/each
EAElectrical, Manualn/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-30 °F2-Way+121 °CPush and Twist60 L/minC10-215 Gal/min350 barNitrileSolenoid operated, Manually operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-34 to +121 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft7-10 NmYesN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARNitrileElectrical, ManualNo
DSH101CRV
Quote Required
$88.50/each
EAElectricaln/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way+204 °Cn/a15 Gal/minC10-260 L/min350 barFluorocarbonSolenoid Operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-15 to +400 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmYesN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNo
DSH101CT
Quote Required
38 In Stock
$117.00/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °FPush and Twist60 L/minC10-260 L/min5000 psiD-Ring (Standard)Solenoid operated, Manually operated0.2 kgNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm5-7 lb-ftNoN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH101CTS
Quote Required
$130.75/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °FPush and Twist15 Gal/minC10-260 L/min350 barD-Ring (Standard)Solenoid operated, Manually operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-37 to +93 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft5-7 lb-ftNoN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualYes
DSH101CTV
Quote Required
$128.25/each
EAElectrical, Manualn/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way+204 °CPush and Twist15 Gal/minC10-260 L/min350 barFluorocarbonSolenoid operated, Manually operated0.41 lbNormally ClosedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-15 to +400 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmNoN/ANormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH101N
Quote Required
23 In Stock
$106.50/each
EAElectricaln/a350 barHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °Fn/a60 L/minC10-215 Gal/min5000 psiD-Ring (Standard)Solenoid Operated0.2 kgNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min70 ms69-75 Nm7-10 NmNoN/ANormally Open15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH101NM
Quote Required
1 Limited Stock
$125.00/each
EAElectrical, Manualn/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+93 °CPush Type w/Flush Rod15 Gal/minC10-260 L/min5000 psiD-Ring (Standard)Solenoid operated, Manually operated0.41 lbNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min70 ms51-55 lb-ft5-7 lb-ftNoN/ANormally Open15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH101NR
Quote Required
33 In Stock
$111.50/each
EAElectricaln/a5000 psiHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way+200 °Fn/a60 L/minC10-260 L/min350 barD-Ring (Standard)Solenoid Operated0.41 lbNormally OpenMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min70 ms69-75 Nm5-7 lb-ftYesN/ANormally Open15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo