Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialDivisionFlow DirectionMaximum Kinematic ViscosityMinimum Operating TemperatureFunctionFlow RateMaximum Flow RateCavity SizeWeightMaximum Operating TemperatureConfigurationActuation TypeFor Fluid TypeOperation TypeValve MaterialOperating TemperatureOverride FunctionalityFilter Efficiency RatingWire Mesh Screen IncludedMounting TypeCoil TypeLeak RateInput VoltageResponse TimeCoil Nut Tightening TorqueFree Reverse FlowAdjustment MechanismMaximum Operating PressureInstallation TorqueMaximum Inlet Pressure RatingSeal MaterialConfigurationFlow RateActuation TypeWire Mesh Screen IncludedMaximum Inlet Pressure Rating
DSL081NREV
Quote Required
$97.50/each
EAFluorocarbonn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way30 L/min8 Gal/minC08-20.25 lb+400 °FNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-15 to +400 °FPush Type w/Extended RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A3600 psi23-27 lb-ft3600 psiFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL081NRM
Quote Required
34 In Stock
$92.50/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way8 Gal/min8 Gal/minC08-20.11 kg+200 °FNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200 °FPush Type w/Flush RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A250 bar23-27 lb-ft3600 psiD-Ring (Standard)Normally Open8 GAL/MIN, 30 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL081NRTVS
Quote Required
$138.00/each
EAFluorocarbonn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way30 L/min30 L/minC08-20.25 lb+204 °CNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-26 to +204 °CPush and TwistISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmYesN/A250 bar23-27 lb-ft250 barFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectrical, ManualYes3600 PSI, 250 BAR
DSL081NRV
Quote Required
$84.25/each
EAFluorocarbonn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way30 L/min8 Gal/minC08-20.25 lb+400 °FNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-26 to +204 °Cn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A250 bar23-27 lb-ft3600 psiFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectricalNo3600 PSI, 250 BAR
DSL081NV
Quote Required
$72.50/each
EAFluorocarbonn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-26 °C2-Way8 Gal/min30 L/minC08-20.25 lb+400 °FNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400 °Fn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms7-10 NmNoN/A3600 psi31-37 Nm3600 psiNitrileNormally Open8 GAL/MIN, 30 L/MINElectricalNo3600 PSI, 250 BAR
DSL101C
3 In Stock
68 In Stock
$61.50/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min15 Gal/minC10-20.41 lb+200 °FNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °Cn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms5-7 lb-ftNoN/A3600 psi37-41 lb-ft3600 psiD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CHR
Quote Required
1 Limited Stock
$72.25/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min15 Gal/minC10-20.41 lb+200 °FNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °Cn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftYesN/A3600 psi37-41 lb-ft3600 psiD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CP
4 In Stock
6 In Stock
$107.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min60 L/minC10-20.41 lb+200 °FNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CPull and ReleaseISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms5-7 lb-ftNoN/A3600 psi50-56 Nm3600 psiD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CR
Quote Required
33 In Stock
$66.50/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way15 Gal/min15 Gal/minC10-20.2 kg+93 °CNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-35 to +200 °Fn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms7-10 NmYesN/A250 bar37-41 lb-ft250 barD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CRP
Quote Required
$113.25/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way15 Gal/min60 L/minC10-20.2 kg+200 °FNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CPull and ReleaseISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms7-10 NmYesN/A250 bar50-56 Nm3600 psiD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRPN
Quote Required
$118.25/each
EANitrilen/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-302-Way1515C10-20.41+250Normally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-30 to +250Pull and ReleaseISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil585% of rated voltage at 72°F (20°C)805-7YesN/A360037-413600NitrileNormally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRT
Quote Required
302 In Stock
$113.25/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way15 Gal/min15 Gal/minC10-20.2 kg+93 °CNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200 °FPush and TwistISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms7-10 NmYesN/A250 bar37-41 lb-ft250 barD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRV
Quote Required
$71.75/each
EAFluorocarbonn/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-15 °F2-Way15 Gal/min15 Gal/minC10-20.2 kg+204 °CNormally ClosedElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400 °Fn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms5-7 lb-ftYesN/A3600 psi37-41 lb-ft250 barFluorocarbonNormally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CT
Quote Required
2 Limited Stock
$107.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min60 L/minC10-20.2 kg+200 °FNormally ClosedElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200 °FPush and TwistISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms5-7 lb-ftNoN/A3600 psi37-41 lb-ft3600 psiD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101N
62 In Stock
43 In Stock
$80.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min15 Gal/minC10-20.41 lb+200 °FNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-35 to +200 °Fn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms5-7 lb-ftNoN/A3600 psi37-41 lb-ft3600 psiD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101NE
Quote Required
1 Limited Stock
$93.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way60 L/min60 L/minC10-20.2 kg+200 °FNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CPush Type w/Extended RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms5-7 lb-ftNoN/A250 bar50-56 Nm3600 psiD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NM
Quote Required
39 In Stock
$93.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min15 Gal/minC10-20.41 lb+93 °CNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CPush Type w/Flush RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms7-10 NmNoN/A250 bar50-56 Nm250 barD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NR
Quote Required
56 In Stock
$88.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-37 °C2-Way60 L/min15 Gal/minC10-20.41 lb+200 °FNormally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °Cn/aISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms7-10 NmYesN/A250 bar37-41 lb-ft250 barD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101NRE
Quote Required
$101.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way60 L/min15 Gal/minC10-20.41 lb+93 °CNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200 °FPush Type w/Extended RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms5-7 lb-ftYesN/A3600 psi37-41 lb-ft250 barD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NRM
Quote Required
33 In Stock
$101.75/each
EAD-Ring (Standard)n/aHydraulic Systems DivisionSide to Nose (2-1)45-2000 SSU (6 to 420 cSt)-35 °F2-Way15 Gal/min15 Gal/minC10-20.2 kg+200 °FNormally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CPush Type w/Flush RodISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min35 ms7-10 NmYesN/A3600 psi37-41 lb-ft250 barD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR