• Availability & Price
  • Search SKU
Filter by attributes
  • Connection Thread Size (inch)
  • Pipe O.D. (inch)
  • Pipe O.D. (mm)
  • Pipe O.D. 2 (inch)
  • Pipe O.D. 2 (mm)
  • Seal Material
  • Shape
More Filters...
Filter by manufacturer
Manufacturers

Transair® Fittings for Stainless Steel Pipe

Picture for category Transair® Fittings for Stainless Steel Pipe

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Transair Fittings for Stainless Steel Pipe are quick and easy to install. All fittings are designed to securely fit around Transair stainless steel pipe, increasing system efficiency and preventing leaks. Transair fittings for stainless steel pipe are available in a variety of styles for easy assembly and layout design for compressed air, vacuum, industrial/inert gas, process water, or chemical transfer system. Fittings are available with either FKM or EPDM for robust chemical compatibility.

The “full bore” design of Transair fittings pair with the low coefficient of friction in the stainless steel pipe ensures optimal flow throughout the system. All components are 100% recyclable, silicone free, and manufactured from materials with no propagation of flame. Parker Hannifin warrants all Transair components to be free of defects in material and workmanship for 10 years from the date of installation.

Transair 3/4" (22mm) and 1” (28mm) fittings use push-to-connect technology. To install, mark the insertion depth on the pipe and insert the pipe into the fitting until the edge of the connector meets the marked line on the pipe.

Transair 1-1/2” (42mm) and 2” (60mm) fittings use clamp ring technology. To install, place the clamp ring over the lugs at the end of the pipe and slide the fitting nut in place. Next, hand tighten the nut onto the body. Lastly, use a pair of spanner wrenches to tighten the fitting one-half (1/2) turn. All 1-1/2” and 2” stainless steel pipe comes from the factory pre-lugged, but if field cutting is required, the lugs need to be made using a Transair lugging tool and die.

Transair 3” (76mm) and 4” (101mm) fittings use clamshell technology. To install, place the remove cartridge over the end of the pipe until it meets the lugs. Next, place the clamshell union over the cartridge and tighten the fitting using a cross bolt pattern. All 3” and 4” stainless steel pipe comes from the factory pre-lugged, but if field cutting is required, the lugs need to be made using a Transair lugging tool and die.

For full installation instructions, download our stainless steel catalog.

Markets:
• Automotive Assembly
• Food & Beverage
• Packaging
• Industrial Plants
• Aerospace

Features/Benefits:
• Quick connection technology
• Modular & reusable
• Corrosion resistant
• Optimum flow rate
• 100% Recyclable
• Faster installation
• Lower installation costs
• Immediate Pressurization
• 10-year warranty

Applications:
• Compressed Air
• Vacuum
• Industrial/Inert Gases (i.e. Argon, Nitrogen, Carbon Dioxide)
• Process Water
• Chemical Transfer

Maximum Working Pressure:
• 145psi (10bar) when the system is operated from +14 to +140F (-20 to +60C)
• 100psi (7bar) when the system is operated from +14 to +194F (-20 to +90C)

Maximum Operating Temperature:
• +194F (+90C) when the system is operated with FKM seals and at 100psi (7bar) or lower

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceVacuum Pressure RatingApplicationMaximum Operating TemperatureMaximum Operating PressureDivisionMinimum Operating TemperaturePipe O.D. (inch)Pipe O.D. (mm)Pipe O.D. 2 (inch)Seal MaterialConnection Thread Size (inch)ShapePipe O.D. 2 (mm)Assembly TimeConnection 2 SizeWeightProduct StyleShapeConnection 1 SizeConfigurationBrandProduct TypeConnection 2 TypeQuantity per BoxConnection 1 TypeDivisionSeal MaterialPipe Outside Diameter
RR05 M6 06
Quote Required
TBD
0.03Vacuum194145Fluid System Connectors Division-42-1/260N/AN/A3/4Transair Male to Male BSP AdapterN/A
RR05 M6 16
Quote Required
TBD
0.03Vacuum194145Fluid System Connectors Division-42-1/260N/AN/A2Transair Male to Male BSP AdapterN/A
RR05 M6 20
Quote Required
TBD
0.03Vacuum194145Fluid System Connectors Division-42-1/260N/AN/A2-1/2Transair Male to Male BSP AdapterN/A
RR05 M6N06
Quote Required
TBD
1Vacuum194145Fluid System Connectors Division-42-1/260N/AN/A3/4Transair Male to Male NPT AdapterN/A
RR05 M6N16
Quote Required
TBD
1Vacuum194145Fluid System Connectors Division-42-1/260N/AN/A2Transair Male to Male NPT AdapterN/A
RR05 M6N20
Quote Required
TBD
1Chemical Transfer194145Fluid System Connectors Division-42-1/260N/AN/A2-1/2Transair Male to Male NPT AdapterN/A
RR05 N7 04 01
Quote Required
TBD
0.03 inch-HgChemical Transfer194 °F10 barFluid System Connectors Division-4 °F3/422N/AEPDM1/2Transair Male to Male BSP AdapterN/A0.17 Hours3/4 inch0.50 lbStud FittingStraight3/4 inchPipe to PortTransairCompressed Air PipingMale BSPT2.0PipeLow Pressure Connectors Europe DivisionEPDM3/4 inch
RR05 N7 04 02
Quote Required
TBD
1 mbarVacuum90 °C145 psiFluid System Connectors Division-4 °F3/422N/AFKM1/2Transair Male to Male BSP AdapterN/A0.17 Hours3/4 inch0.50 lbStraight3/4 inchPipe to PortTransairCompressed Air PipingMale BSPT2.0PipeLow Pressure Connectors Europe DivisionFKM3/4 inch
RR05 N7 06 01
Quote Required
TBD
0.03 inch-HgInert Gases90 °C145 psiFluid System Connectors Division-20 °C3/422N/AEPDM3/4Transair Male to Male BSP AdapterN/A0.17 Hours3/4 inch0.50 lbStud FittingStraight3/4 inchPipe to PortTransairCompressed Air PipingMale BSPT2.0PipeLow Pressure Connectors Europe DivisionEPDM22 mm
RR05 N7 06 02
Quote Required
TBD
0.03 inch-HgInert Gases194 °F10 barFluid System Connectors Division-20 °C3/422N/AFKM3/4Transair Male to Male BSP AdapterN/A0.17 Hours3/4 inch0.50 lbStud FittingAdapter3/4 inchPipe to PortTransairCompressed Air PipingMale BSPT2.0PipeLow Pressure Connectors Europe DivisionFKM22 mm
RR05 N7N06 01
Quote Required
TBD
1 mbarCompressed Air194 °F10 barFluid System Connectors Division-20 °C3/422N/AEPDM3/4Transair Female to Male NPT AdapterN/A0.17 Hours3/4 inch0.50 lbStud FittingStraight3/4 inchPipe to PortTransairCompressed Air PipingMale NPT2.0PipeFluid System Connectors DivisionEPDM3/4 inch
RR05 N7N06 02
Quote Required
TBD
0.03 inch-HgInert Gases194 °F145 psiFluid System Connectors Division-20 °C3/422N/AFKM3/4Transair Female to Male NPT AdapterN/A0.17 Hours3/4 inch0.50 lbStud FittingStraight22 mmPipe to PortTransairCompressed Air PipingMale NPT2.0PipeLow Pressure Connectors Europe DivisionFKM22 mm
RR05 N9 08 01
Quote Required
TBD
0.03Vacuum194145Fluid System Connectors Division-4128N/AEPDM1Transair Male to Male BSP AdapterN/A
RR05 N9 08 02
Quote Required
TBD
0.03Vacuum194145Fluid System Connectors Division-4128N/AFKM1Transair Male to Male BSP AdapterN/A
RR05 N9N08 01
Quote Required
TBD
1 mbarCompressed Air194 °F10 barFluid System Connectors Division-4 °F128N/AEPDM1Transair Female to Male NPT AdapterN/A
RR05 N9N08 02
Quote Required
TBD
0.03 inch-HgVacuum90 °C10 barFluid System Connectors Division-20 °C128N/AFKM1Transair Female to Male NPT AdapterN/A
RR06 N7 01
Quote Required
TBD
0.03 inch-HgChemical Transfer194 °F145 psiFluid System Connectors Division-4 °F3/422N/AEPDMn/aUnionN/A0.04 Hours3/4 inch0.28 lbUnion FittingStraight3/4 inchPipe to PipeTransairUnion FittingPipe5.0PipeLow Pressure Connectors Europe DivisionEPDM22 mm
RR06 N7 02
Quote Required
TBD
0.03 inch-HgCompressed Air90 °C10 barFluid System Connectors Division-4 °F3/422N/AFKMn/aUnionN/A0.04 Hours22 mm0.13 kgUnion FittingStraight22 mmPipe to PipeTransairUnion FittingPipe5.0PipeFluid System Connectors DivisionFKM3/4 inch
RR06 N9 01
Quote Required
TBD
1Vacuum194145Fluid System Connectors Division-4128N/AEPDMn/aUnionN/A
RR06 N9 02
Quote Required
TBD
1Vacuum194145Fluid System Connectors Division-4128N/AFKMn/aUnionN/A