Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
| Action | Part No. | Availability | Partner Available | Price | Division | Maximum Inlet Pressure Rating | Operating Temperature | Division | Mounting Type | Body Material | Pressure Control Range | Holding Pressure | Flow Rate | Flow Direction | Seal Material | Cavity Size | Function | Actuation Type | Weight | Maximum Operating Pressure | Filter Efficiency Rating | Valve Material | Pilot Location | Pilot Pressure Ratio | Maximum Flow Rate | Installation Torque | Pressure Control Sensitivity | Leak Rate | Minimum Operating Temperature | For Fluid Type | Maximum Kinematic Viscosity | Adjustment Mechanism | Port Size | Maximum Operating Temperature | Port Size | Seal Material | Pressure Control Range | Pilot Pressure Ratio | Maximum Flow Rate | Mounting Type | Adjustment Mechanism | Holding Pressure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MHC-022-VJSH-00F | Quote Required | TBD | Hydraulic Cartridge Systems Division | 5000 psi | -26 to +204 °C | Hydraulic Systems Division | Threaded Cartridge Valve | n/a | N/A bar | 210 bar | 25 Gal/min | Cylinder port 2, Valve port 3, Pilot port 1 | Fluorocarbon | CDD-1036 | Counterbalance Valve | Pilot Operated, Vented | 0.38 kg | 5000 psi | ISO 4406 18/16/13, SAE Class 4 | All parts steel. All operating parts hardened steel | External | 10:1 | 93.75 L/min | 75-80 lb-ft | N/A bar | 5 @ 80% of setting drops/min | -15 °F | Mineral-based or synthetic hydraulic fluids | 45-2000 SSU (6 to 420 cSt) | Standard (adjustable) | n/a | +400 °F | n/a | Fluorocarbon | N/A | 10:1 | 25 GAL/MIN, 93.75 L/MIN | Threaded Cartridge Valve | Standard (adjustable) | 3000 PSI, 210 BAR | ||
| MHC-022-VJSJ-00B | Quote Required | TBD | Hydraulic Valve Systems Division | 5000 | -30 to +250 | Hydraulic Systems Division | Threaded Cartridge Valve | n/a | n/a | 3500 | 25 | Cylinder port 2, Valve port 3, Pilot port 1 | Nitrile | CDD-1036 | Counterbalance Valve | Pilot Operated, Vented | 0.88 | 5000 | ISO 4406 18/16/13, SAE Class 4 | All parts steel. All operating parts hardened steel | External | 10:1 | 25 | 102-108 | n/a | 5 @ 80% of setting | -30 | Mineral-based or synthetic hydraulic fluids | 45-2000 SSU (6 to 420 cSt) | Standard (adjustable) | n/a | +250 | n/a | Nitrile | N/A | 10:1 | 25 GAL/MIN, 93.75 L/MIN | Threaded Cartridge Valve | Standard (adjustable) | 3500 PSI, 240 BAR | ||
| MHC-022-VJSJ-00F | Quote Required | TBD | Hydraulic Valve Systems Division | 5000 | -15 to +400 | Hydraulic Systems Division | Threaded Cartridge Valve | n/a | n/a | 3500 | 25 | Cylinder port 2, Valve port 3, Pilot port 1 | Fluorocarbon | CDD-1036 | Counterbalance Valve | Pilot Operated, Vented | 0.88 | 5000 | ISO 4406 18/16/13, SAE Class 4 | All parts steel. All operating parts hardened steel | External | 10:1 | 25 | 102-108 | n/a | 5 @ 80% of setting | -15 | Mineral-based or synthetic hydraulic fluids | 45-2000 SSU (6 to 420 cSt) | Standard (adjustable) | n/a | +400 | n/a | Fluorocarbon | N/A | 10:1 | 25 GAL/MIN, 93.75 L/MIN | Threaded Cartridge Valve | Standard (adjustable) | 3500 PSI, 240 BAR | ||
| MHC-022-VJSK-00B | Quote Required | TBD | Hydraulic Cartridge Systems Division | 5000 psi | -30 to +250 °F | Hydraulic Systems Division | Threaded Cartridge Valve | n/a | N/A bar | 350 bar | 25 Gal/min | Cylinder port 2, Valve port 3, Pilot port 1 | Nitrile | CDD-1036 | Counterbalance Valve | Pilot Operated, Vented | 0.38 kg | 5000 psi | ISO 4406 18/16/13, SAE Class 4 | All parts steel. All operating parts hardened steel | External | 10:1 | 93.75 L/min | 102-108 Nm | N/A bar | 5 @ 80% of setting drops/min | -34 °C | Mineral-based or synthetic hydraulic fluids | 45-2000 SSU (6 to 420 cSt) | Standard (adjustable) | n/a | +250 °F | n/a | Nitrile | N/A | 10:1 | 25 GAL/MIN, 93.75 L/MIN | Threaded Cartridge Valve | Standard (adjustable) | 5000 PSI, 350 BAR | ||
| MHC-022-VJSK-00F | Quote Required | TBD | Hydraulic Cartridge Systems Division | 5000 psi | -15 to +400 °F | Hydraulic Systems Division | Threaded Cartridge Valve | n/a | N/A psi | 350 bar | 25 Gal/min | Cylinder port 2, Valve port 3, Pilot port 1 | Fluorocarbon | CDD-1036 | Counterbalance Valve | Pilot Operated, Vented | 0.38 kg | 5000 psi | ISO 4406 18/16/13, SAE Class 4 | All parts steel. All operating parts hardened steel | External | 10:1 | 25 Gal/min | 75-80 lb-ft | N/A bar | 5 @ 80% of setting drops/min | -15 °F | Mineral-based or synthetic hydraulic fluids | 45-2000 SSU (6 to 420 cSt) | Standard (adjustable) | n/a | +400 °F | n/a | Fluorocarbon | N/A | 10:1 | 25 GAL/MIN, 93.75 L/MIN | Threaded Cartridge Valve | Standard (adjustable) | 5000 PSI, 350 BAR |