Picture for category Standard Pilot Vented Load Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionMaximum Inlet Pressure RatingOperating TemperatureDivisionMounting TypeBody MaterialPressure Control RangeHolding PressureFlow RateFlow DirectionSeal MaterialCavity SizeFunctionActuation TypeWeightMaximum Operating PressureFilter Efficiency RatingValve MaterialPilot LocationPilot Pressure RatioMaximum Flow RateInstallation TorquePressure Control SensitivityLeak RateMinimum Operating TemperatureFor Fluid TypeMaximum Kinematic ViscosityAdjustment MechanismPort SizeMaximum Operating TemperaturePort SizeSeal MaterialPressure Control RangePilot Pressure RatioMaximum Flow RateMounting TypeAdjustment MechanismHolding Pressure
MHC-022-VJSH-00F
Quote Required
TBD
Hydraulic Cartridge Systems Division5000 psi-26 to +204 °CHydraulic Systems DivisionThreaded Cartridge Valven/aN/A bar210 bar25 Gal/minCylinder port 2, Valve port 3, Pilot port 1FluorocarbonCDD-1036Counterbalance ValvePilot Operated, Vented0.38 kg5000 psiISO 4406 18/16/13, SAE Class 4All parts steel. All operating parts hardened steelExternal10:193.75 L/min75-80 lb-ftN/A bar5 @ 80% of setting drops/min-15 °FMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)Standard (adjustable)n/a+400 °Fn/aFluorocarbonN/A10:125 GAL/MIN, 93.75 L/MINThreaded Cartridge ValveStandard (adjustable)3000 PSI, 210 BAR
MHC-022-VJSJ-00B
Quote Required
TBD
Hydraulic Valve Systems Division5000-30 to +250Hydraulic Systems DivisionThreaded Cartridge Valven/an/a350025Cylinder port 2, Valve port 3, Pilot port 1NitrileCDD-1036Counterbalance ValvePilot Operated, Vented0.885000ISO 4406 18/16/13, SAE Class 4All parts steel. All operating parts hardened steelExternal10:125102-108n/a5 @ 80% of setting-30Mineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)Standard (adjustable)n/a+250n/aNitrileN/A10:125 GAL/MIN, 93.75 L/MINThreaded Cartridge ValveStandard (adjustable)3500 PSI, 240 BAR
MHC-022-VJSJ-00F
Quote Required
TBD
Hydraulic Valve Systems Division5000-15 to +400Hydraulic Systems DivisionThreaded Cartridge Valven/an/a350025Cylinder port 2, Valve port 3, Pilot port 1FluorocarbonCDD-1036Counterbalance ValvePilot Operated, Vented0.885000ISO 4406 18/16/13, SAE Class 4All parts steel. All operating parts hardened steelExternal10:125102-108n/a5 @ 80% of setting-15Mineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)Standard (adjustable)n/a+400n/aFluorocarbonN/A10:125 GAL/MIN, 93.75 L/MINThreaded Cartridge ValveStandard (adjustable)3500 PSI, 240 BAR
MHC-022-VJSK-00B
Quote Required
TBD
Hydraulic Cartridge Systems Division5000 psi-30 to +250 °FHydraulic Systems DivisionThreaded Cartridge Valven/aN/A bar350 bar25 Gal/minCylinder port 2, Valve port 3, Pilot port 1NitrileCDD-1036Counterbalance ValvePilot Operated, Vented0.38 kg5000 psiISO 4406 18/16/13, SAE Class 4All parts steel. All operating parts hardened steelExternal10:193.75 L/min102-108 NmN/A bar5 @ 80% of setting drops/min-34 °CMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)Standard (adjustable)n/a+250 °Fn/aNitrileN/A10:125 GAL/MIN, 93.75 L/MINThreaded Cartridge ValveStandard (adjustable)5000 PSI, 350 BAR
MHC-022-VJSK-00F
Quote Required
TBD
Hydraulic Cartridge Systems Division5000 psi-15 to +400 °FHydraulic Systems DivisionThreaded Cartridge Valven/aN/A psi350 bar25 Gal/minCylinder port 2, Valve port 3, Pilot port 1FluorocarbonCDD-1036Counterbalance ValvePilot Operated, Vented0.38 kg5000 psiISO 4406 18/16/13, SAE Class 4All parts steel. All operating parts hardened steelExternal10:125 Gal/min75-80 lb-ftN/A bar5 @ 80% of setting drops/min-15 °FMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)Standard (adjustable)n/a+400 °Fn/aFluorocarbonN/A10:125 GAL/MIN, 93.75 L/MINThreaded Cartridge ValveStandard (adjustable)5000 PSI, 350 BAR