Standard Pilot Vented Load Control Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
| Action | Part No. | Availability | Partner Available | Price | Mounting Type | Port Size | Leak Rate | Body Material | Operating Temperature | Maximum Flow Rate | Pilot Location | Minimum Operating Temperature | Division | Installation Torque | Flow Rate | Seal Material | Holding Pressure | Actuation Type | Weight | Port Thread Size | Maximum Kinematic Viscosity | Filter Efficiency Rating | Maximum Inlet Pressure Rating | Adjustment Mechanism | Valve Material | Flow Direction | Maximum Operating Pressure | Pressure Control Sensitivity | Function | Pilot Pressure Ratio | Cavity Size | Maximum Operating Temperature | Pressure Control Range | For Fluid Type | Division | Seal Material | Port Size | Adjustment Mechanism | Mounting Type | Holding Pressure | Pilot Pressure Ratio | Pressure Control Range | Maximum Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| E6A060ZN409 | Quote Required | 23 In Stock | $843.65/each | Threaded Cartridge Valve | N/A | 6 @ 1450 PSI (100 BAR) drops/min | N/A | -30 to +250 °F | 180 L/min | External | -30 °F | Mobile Hydraulic Systems Division Europe | 85 Nm | 48 Gal/min | Nitrile | 3120 psi | Pilot Operated, Vented | 0.53 kg | N/A | Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt | ISO 4406 18/16/13, SAE Class 4 | 5000 psi | Screw Adjustment | All parts steel. All operating parts hardened steel | Cylinder port 1, Valve port 2, Pilot port 3 | 350 bar | 50 per turn bar | Counterbalance Valve | 8:01 | 3C | +250 °F | 725-5000 psi | Mineral-based or synthetic hydraulic fluids | Hydraulic Cartridge Systems Division | Nitrile | n/a | Screw | Threaded Cartridge Valve | 3120 PSI, 215 BAR | 8:1 | 725-5000 PSI, 50-350 BAR | 48 GAL/MIN, 180 L/MIN | |
| E6B040ZNMK3 | Quote Required | $533.00/each | Threaded Cartridge Valve | N/A | 6 @ 1450 PSI (100 BAR) drops/min | N/A | -34° to +121° °C | 60 L/min | External | -34 °C | Mobile Hydraulic Systems Division Europe | 40 lb-ft | 60 L/min | Nitrile | 215 bar | Pilot Operated, Vented | 0.73 lb | N/A | Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt | ISO 4406:1999 Code 18/16/13 | 350 bar | Screw | All parts steel. All operating parts hardened steel | Cylinder port 1, Valve port 2, Pilot port 3 | 5000 psi | 1335 per turn psi | Counterbalance Valve | 3:01 | 68-1 | +250 °F | 50-350 bar | Mineral-based or synthetic hydraulic fluids | Hydraulic Cartridge Systems Division | Nitrile | n/a | Screw | Threaded Cartridge Valve | 3120 PSI, 215 BAR | 3:1 | 725-5000 PSI, 50-350 BAR | 15.9 GAL/MIN, 60 L/MIN | ||
| E6B060ZN409 | Quote Required | $459.00/each | Threaded Cartridge Valve | N/A | 6 @ 1450 PSI (100 BAR) drops/min | N/A | -34° to +121° °C | 180 L/min | External | -34 °C | Mobile Hydraulic Systems Division Europe | 63 lb-ft | 48 Gal/min | Nitrile | 215 bar | Pilot Operated, Vented | 1.17 lb | N/A | 45-2000 SSU (6 to 420 cSt) | ISO 4406 18/16/13, SAE Class 4 | 350 bar | Screw | All parts steel. All operating parts hardened steel | Cylinder port 1, Valve port 2, Pilot port 3 | 350 bar | 50 per turn bar | Counterbalance Valve | 3:1 | 3C | +121 °C | 50-350 bar | Mineral-based or synthetic hydraulic fluids | Hydraulic Cartridge Systems Division | Nitrile | n/a | Screw | Threaded Cartridge Valve | 3120 PSI, 215 BAR | 3:1 | 725-5000 PSI, 50-350 BAR | 48 GAL/MIN, 180 L/MIN |