• Availability & Price
  • Search SKU
Filter by attributes
  • Configuration
  • Maximum Flow Rate
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Proportional Poppet Valves

Picture for category Proportional Poppet Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 2-way proportional poppet valves provide precise and dependable controls for applications that require a proportional flow control with an extremely low leakage rate. These valves are capable of handling flows up to 117 lpm (31 gpm) and pressures as high as 210 bar (3000 psi). These valves inspire confidence because of the high level of repeatable and accurate operation throughout the full control range of the valve. Parker’s 2-way proportional poppet valves are available in normally-open or normally-closed configurations and will pair with any Current Controlled Pulse Width Modulation (PWM) valve driver. These valves have uses on a variety of machinery within the agriculture, aerial, material handling, or construction markets.

Markets:
• Agriculture
• Aerial
• Construction
• Material Handling
• Miscellaneous Mobile

Features/Benefits:
• Excellent metering capability and control throughout the full flow range
• Reduced drift
• Low leak control (less than 5 dpm)
• Modular solution to applied problem
• Improved control throughout the control range

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMActuation TypeMaximum Operating PressureSeal MaterialBody MaterialDivisionDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureWeightOverride FunctionalityMaximum Inlet Pressure RatingCavity SizeMaximum Operating TemperatureFunctionFrequencyConfigurationFlow DirectionFor Fluid TypeValve MaterialOperating TemperatureFilter Efficiency RatingVariation of Closing PointHysteresisLeak RateInstallation TorqueFlow RateMaximum Flow RateCoil TypePower ConsumptionCoil Nut Tightening TorqueVariation of Opening PointMinimum Pressure DifferentialSeal MaterialConfigurationMaximum Flow Rate
FAP121CN
Quote Required
$413.00
EAElectrical3000 psiNitrilen/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C0.65 lbn/a3000 psiC12-2F+121 °CProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4N/A< 15%5 @ 3000 PSI (210 BAR) drops/min55 lb-ft21.5 Gal/min21.5 Gal/min5/8" Super Coil Low Watt (CAS)18 W1.4 Nm20-25% of Input Signal21 barNitrileNormally Closed21.5 GAL/MIN, 81.5 L/MIN
FAP121CV
Quote Required
TBD
Electrical210 barFluorocarbonn/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F0.65 lbn/a3000 psiC12-2F+400 °FProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4N/A< 15%5 @ 3000 PSI (210 BAR) drops/min74 Nm21.5 Gal/min21.5 Gal/min5/8" Super Coil Low Watt (CAS)18 W1.4 Nm20-25% of Input Signal300 psiFluorocarbonNormally Closed21.5 GAL/MIN, 81.5 L/MIN
FAP121NN
Quote Required
TBD
Electrical210 barNitrilen/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F0.68 lbn/a210 barC12-2F+250 °FProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 460-65% of Input Signal< 15%5 @ 3000 PSI (210 BAR) drops/min55 lb-ft26 Gal/min98.5 L/min5/8" Super Coil Low Watt (CAS)18 W1.4 NmN/A300 psiNitrileNormally Open26 GAL/MIN, 98.5 L/MIN
FAP121NV
Quote Required
TBD
Electrical210 barFluorocarbonn/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C0.68 lbn/a3000 psiC12-2F+400 °FProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 460-65% of Input Signal< 15%5 @ 3000 PSI (210 BAR) drops/min55 lb-ft26 Gal/min26 Gal/min5/8" Super Coil Low Watt (CAS)18 W1 lb-ftN/A21 barFluorocarbonNormally Open26 GAL/MIN, 98.5 L/MIN
FAP161CN
Quote Required
TBD
Electrical3000 psiNitrilen/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F0.4 kgn/a3000 psiC16-2+121 °CProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4N/A< 15%5 @ 3000 PSI (210 BAR) drops/min80-85 lb-ft106 L/min106 L/min5/8" Super Coil Low Watt (CAS)18 W1 lb-ft20-25% of Input Signal21 barNitrileNormally Closed28 GAL/MIN, 106 L/MIN
FAP161CV
Quote Required
TBD
Electrical3000 psiFluorocarbonn/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F0.4 kgn/a3000 psiC16-2+204 °CProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4N/A< 15%5 @ 3000 PSI (210 BAR) drops/min80-85 lb-ft28 Gal/min28 Gal/min5/8" Super Coil Low Watt (CAS)18 W1.4 Nm20-25% of Input Signal300 psiFluorocarbonNormally Closed28 GAL/MIN, 106 L/MIN
FAP161NN
Quote Required
TBD
Electrical210 barNitrilen/aHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C0.9 lbn/a3000 psiC16-2+250 °FProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 460-65% of Input Signal< 15%5 @ 3000 PSI (210 BAR) drops/min108-115 Nm31 Gal/min31 Gal/min5/8" Super Coil Low Watt (CAS)18 W1.4 NmN/A21 barNitrileNormally Open31 GAL/MIN, 117 L/MIN
FAP161NV
Quote Required
TBD
Electrical3000 psiFluorocarbonn/aHydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C0.41 kgn/a3000 psiC16-2+400 °FProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 460-65% of Input Signal< 15%5 @ 3000 PSI (210 BAR) drops/min108-115 Nm31 Gal/min31 Gal/min5/8" Super Coil Low Watt (CAS)18 W1.4 NmN/A21 barFluorocarbonNormally Open31 GAL/MIN, 117 L/MIN