• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Pressure Differential
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Pressure Compensators/Control Elements

Picture for category Pressure Compensators/Control Elements

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of pressure compensator valves feature a robust and contamination tolerant design that ensures consistent flow regardless of up or down stream pressures. These valves can operate with hydraulic system flows as high as 150 lpm and pressures up to 245 bar with a variety of differential pressure setting options. Parker’s pressure compensator valves are ideal for constant and consistent flow applications such as conveyors or saws within mobile, industrial, or manufacturing markets.

Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Stable and quiet response
• Contamination tolerant
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Conveyors
• Saws
• Constant and consistent flow applications

Additional Technical Insight:
Inlet flow (upstream of the orifice or flow control valve) is split with one portion going to the compensator port inlet, the other portion passes through the orifice, or flow control valve, to the supply port. As pressure drop across the orifice reaches the selected compensator pressure drop, the higher pressure (pre-orifice) starts to shift the compensator spool into a throttling position. The valve works to maintain a constant pressure drop across the orifice. Using this type of valve allows greater flexibility in design and flows as these valves can flow as much as 40 gallons per minute. Compensator valves are used in circuits where a constant flow is desired regardless of upstream or downstream loads. As the pressure downstream of the compensator increases, the valve is forced open to maintain the constant pressure drop across the fixed, or adjustable, orifice. Conversely, if the pressure increases upstream of the orifice, the compensator valve will be forced closed to maintain the constant pressure drop across the orifice.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceAdjustment MechanismValve MaterialFlow Rate AccuracyPressure DifferentialFlow RateFilter Efficiency RatingConfigurationMaximum Flow RateActuation TypeDivisionSeal MaterialOperation TypeBody MaterialConnection TypeDivisionInstallation TorqueOperating TemperatureCavity SizeMaximum Operating TemperatureConnection SizeFor Fluid TypeMaximum Kinematic ViscosityMinimum Operating TemperatureWeightMaximum Inlet Pressure RatingFunctionMaximum Operating PressureMaximum Flow RatePressure DifferentialSeal Material
FCR101F
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%160 psi38 L/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)38 L/minRestrictive typeHydraulic Systems DivisionNitrilePressure sensingn/an/aHydraulic Cartridge Systems Division22 Nm-34 to +121 °CC10-3245 barn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)-34 °C0.3 lb3500 psiPressure Compensating Valve3500 psi10 GAL/MIN, 38 L/MIN160 PSI, 11 BARNitrile
FCR101F04
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%2.8 bar10 Gal/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)38 L/minRestrictive typeHydraulic Systems DivisionNitrilePressure sensingn/an/aHydraulic Cartridge Systems Division22 Nm-30 to +250 °FC10-3+121 °Cn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+250 °F0.3 lb3500 psiPressure Compensating Valve3500 psi10 GAL/MIN, 38 L/MIN40 PSI, 2.8 BARNitrile
FCR101F04V
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%4038ISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)10Restrictive typeHydraulic Systems DivisionFluorocarbonPressure sensingn/an/aHydraulic Valve Systems Division16-15 to +400C10-3245n/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+4000.33500Pressure Compensating Valve350010 GAL/MIN, 38 L/MIN40 PSI, 2.8 BARFluorocarbon
FCR101F08
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%5.5 bar38 L/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)38 L/minRestrictive typeHydraulic Systems DivisionNitrilePressure sensingn/an/aHydraulic Cartridge Systems Division16 lb-ft-30 to +250 °FC10-3+121 °Cn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+250 °F0.14 kg245 barPressure Compensating Valve3500 psi10 GAL/MIN, 38 L/MIN80 PSI, 5.8 BARNitrile
FCR101F08V
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%8038ISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)10Restrictive typeHydraulic Systems DivisionFluorocarbonPressure sensingn/an/aHydraulic Valve Systems Division16-15 to +400C10-3245n/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+4000.33500Pressure Compensating Valve350010 GAL/MIN, 38 L/MIN80 PSI, 5.8 BARFluorocarbon
FCR101FV
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%16038ISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)10Restrictive typeHydraulic Systems DivisionFluorocarbonPressure sensingn/an/aHydraulic Valve Systems Division16-15 to +400C10-3245n/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+4000.33500Pressure Compensating Valve350010 GAL/MIN, 38 L/MIN160 PSI, 11 BARFluorocarbon
FCR161F
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%160 psi40 Gal/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)40 Gal/minRestrictive typeHydraulic Systems DivisionNitrilePressure sensingn/an/aHydraulic Cartridge Systems Division40 lb-ft-30 to +250 °FC16-3245 barn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)-30 °F0.34 kg245 barPressure Compensating Valve3500 psi40 GAL/MIN, 150 L/MIN160 PSI, 11 BARNitrile
FCR161F04
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%2.8 bar40 Gal/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)40 Gal/minRestrictive typeHydraulic Systems DivisionNitrilePressure sensingn/an/aHydraulic Cartridge Systems Division40 lb-ft-34 to +121 °CC16-3245 barn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)+250 °F0.75 lb3500 psiPressure Compensating Valve3500 psi40 GAL/MIN, 150 L/MIN40 PSI, 2.8 BARNitrile
FCR161FV
Quote Required
TBD
FixedAll parts steel. All operating parts hardened steel10%160 psi150 L/minISO 4406 18/16/13, SAE Class 4Used with external orifice (fixed or variable)150 L/minRestrictive typeHydraulic Systems DivisionFluorocarbonPressure sensingn/an/aHydraulic Cartridge Systems Division54 Nm-26 to +204 °CC16-3+204 °Cn/aMineral-based or synthetic hydraulic fluids45-2000 SSU (6 to 420 cSt)-15 °F0.34 kg3500 psiPressure Compensating Valve3500 psi40 GAL/MIN, 150 L/MIN160 PSI, 11 BARFluorocarbon