• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Mechanism
  • Flow Rate Display Range
  • Maximum Flow Rate
  • Seal Material
  • Standard Flow Rate Setting
More Filters...
Filter by manufacturer
Manufacturers

Pressure Compensated Priority Flow Control Valves

Picture for category Pressure Compensated Priority Flow Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of pressure compensated priority flow control valves feature a proven design that allows for a reliable and repeatable flow compensation curve throughout a wide pressure range while ensuring priority flow is met. These valves can operate with hydraulic system flows as high as 90 lpm and pressures up to 420 bar with a selection of adjustment and tamper-proof options. Parker’s pressure compensated priority flow control valves are ideal for steering, brake, or actuator control applications within a broad range of markets, such as the agriculture, construction, material handling, industrial, and oil & gas markets.

Markets:
• Agriculture
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Fine adjustments
• Reverse flow function
• Hardened working parts for maximum durability
• Tamperproof options available
• All external parts zinc plated

Applications:
• Steering applications
• Actuator speed control
• Meter-in circuits

Additional Technical Insight:
Priority style pressure compensator flow control valves maintain constant priority flow to one leg of a circuit regardless of any changes in load or inlet pressure. Once the priority flow is satisfied, any excess flow may be used in other parts of the circuit. The valve consists of a control orifice housed within a spring biased compensator spool. This orifice may be fixed or adjustable. The priority port is normally open while the bypass port is normally closed. As flow enters the inlet port of the cartridge, it passes through the control orifice. A pressure differential is created across the compensator spool. If the inlet flow exceeds the setting of the valve, the force produced by this pressure differential exceeds the spring force and shifts the compensator spool; opening up the bypass port, and bypassing the excess flow. If the load pressure at the bypass port is greater than the load pressure at the priority port, the compensator spool will further shift restricting the priority flow to that of the valve setting. However, caution should be taken if the priority gets blocked so that no flow can pass through the control orifice, the compensator spool will shift, blocking the bypass port and allowing inlet pressure to go to full system relief pressure. It is common to place an external relief valve downstream of the priority flow port to prevent a no flow condition.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMMaximum Regulated Flow RateFilter Efficiency RatingMaximum Priority FlowFlow RateSeal MaterialDivisionDivisionActuation TypeAdjustment MechanismConnection TypeBody MaterialValve MaterialInstallation TorqueMaximum Inlet Pressure RatingConfigurationOperating TemperatureMaximum Flow RateOperation TypeCavity SizeMaximum Kinematic ViscosityFlow Rate Display RangeFunctionWeightMinimum Operating TemperatureFor Fluid TypeConnection SizeFlow Rate AccuracyStandard Flow Rate SettingMaximum Operating TemperatureMaximum Operating PressureAdjustment MechanismFlow Rate Display RangeMaximum Flow RateSeal MaterialStandard Flow Rate Setting
FP101F300
1 Limited Stock
Quote Required
$135.25/each
EAN/A L/minISO 4406 18/16/13, SAE Class 430 L/min15 Gal/minNitrileHydraulic Cartridge Systems DivisionHydraulic Systems DivisionPressure CompensatedFixedn/an/aAll parts steel. All operating parts hardened steel22 Nm245 barPriority Flow-34 to +121 °C15 Gal/minAutomaticC10-345-2000 SSU (6 to 420 cSt)N/A L/minFlow Regulator Valve0.23 kg-34 °CMineral-based or synthetic hydraulic fluidsn/a20%3 Gal/min+250 °F3500 psiFixedN/A15 GAL/MIN, 56.3 L/MINNitrile3 GAL/MIN, 11.3 L/MIN
FP101K295
Quote Required
$135.75/each
EAN/A L/minISO 4406 18/16/13, SAE Class 49 Gal/min56.3 L/minNitrileHydraulic Cartridge Systems DivisionHydraulic Systems DivisionPressure CompensatedKnobn/an/aAll parts steel. All operating parts hardened steel22 Nm245 barPriority Flow-34 to +121 °C15 Gal/minManually operatedC10-345-2000 SSU (6 to 420 cSt)8.6-13.5 L/minFlow Regulator Valve0.23 kg-30 °FMineral-based or synthetic hydraulic fluidsn/a20%N/A L/min+121 °C3500 psiKnob2.3-3.6 GAL/MIN, 8.6-13.5 L/MIN15 GAL/MIN, 56.3 L/MINNitrileN/A
FP101S155
Quote Required
$121.50/each
EAN/A L/minISO 4406 18/16/13, SAE Class 49 Gal/min15 Gal/minNitrileHydraulic Cartridge Systems DivisionHydraulic Systems DivisionPressure CompensatedScrewn/an/aAll parts steel. All operating parts hardened steel22 Nm245 barPriority Flow-34 to +121 °C56.3 L/minManually operatedC10-345-2000 SSU (6 to 420 cSt)4.5-7.1 L/minFlow Regulator Valve0.5 lb-30 °FMineral-based or synthetic hydraulic fluidsn/a20%N/A L/min+121 °C3500 psiScrew1.2-1.9 GAL/MIN, 4.5-7.1 L/MIN15 GAL/MIN, 56.3 L/MINNitrileN/A
FP101S295
Quote Required
$121.50/each
EAN/A L/minISO 4406 18/16/13, SAE Class 433.8 L/min56.3 L/minNitrileHydraulic Cartridge Systems DivisionHydraulic Systems DivisionPressure CompensatedScrewn/an/aAll parts steel. All operating parts hardened steel22 Nm3500 psiPriority Flow-34 to +121 °C56.3 L/minManually operatedC10-345-2000 SSU (6 to 420 cSt)8.6-13.5 L/minFlow Regulator Valve0.5 lb-34 °CMineral-based or synthetic hydraulic fluidsn/a20%N/A L/min+250 °F245 barScrew2.3-3.6 GAL/MIN, 8.6-13.5 L/MIN15 GAL/MIN, 56.3 L/MINNitrileN/A
J04D3WN
Quote Required
TBD
EA45 L/minISO 4406 18/16/13, SAE Class 4N/A L/min70 L/minNitrileHydraulic Cartridge Systems DivisionMobile Hydraulic Systems Division EuropePressure CompensatedKnobn/an/aAll parts steel. All operating parts hardened steel50 Nm6000 psiPriority Flow-34 to +121 °C18 Gal/minManually operatedC10-345-2000 SSU (6 to 420 cSt)2-45 L/minFlow Regulator Valve0.18 kg-30 °FMineral-based or synthetic hydraulic fluidsn/aN/A5.3 Gal/min+250 °F420 barKnob0.5-12 GAL/MIN, 2-45 L/MIN18 GAL/MIN,70 L/MINNitrile5.3 GAL/MIN, 20 L/MIN
J1A125ZN
Quote Required
7 In Stock
$424.50/each
EA90 L/minISO 4406 18/16/13, SAE Class 4N/A L/min150 L/minNitrileHydraulic Cartridge Systems DivisionMobile Hydraulic Systems Division EuropePressure CompensatedScrewn/an/aAll parts steel. All operating parts hardened steel63 lb-ft350 barPriority Flow-34 to +121 °C150 L/minManually operated3A45-2000 SSU (6 to 420 cSt)N/A L/minFlow Regulator Valve1 lb-30 °FMineral-based or synthetic hydraulic fluidsn/aN/A25 L/MIN@45 L/MIN Inlet L/min+121 °C5000 psiScrewN/A40 GAL/MIN,150 L/MINNitrile6.6 GAL/[email protected] GAL/MIN Inlet, 25 L/MIN@45 L/MIN Inlet