Parker’s family of pressure compensated flow control valves feature a proven design that allows for a reliable and repeatable flow compensation curve throughout a wide pressure range. These valves can operate with hydraulic system flows as high as 56 lpm and pressures up to 420 bar with the option of an integrated adjustable or tuneable reverse free-flow check valve. Parker’s pressure compensated flow control valves are ideal for cylinder or motor control and/or bleed-off applications within a broad range of markets, such as the agriculture, construction, material handling, industrial, and oil & gas markets.

Markets:
• Agriculture
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Minimal flow change with pressure variation
• Reverse flow function
• Hardened working parts for maximum durability
• Tamperproof options available
• All external parts zinc plated

Applications:
• Accumulator bleed-off
• Motor speed control
• Cylinder speed control
• Power units

Additional Technical Insight:
Parker offers a wide range of spool type restrictive pressure compensated flow controls to allow for speed control of motors, cylinders, and rotary actuators. Pressure compensation allows the flow devices to maintain a constant flow even with varying loads and inlet pressures. Tunable and fully adjustable versions are available with screw or knob adjusters that can be made tamper resistant with the addition of an optional cap. FR101 is an adjustable pressure compensated flow regulator which compensates for varying loads and pressures in one direction but in the other direction flow is metered across a fixed orifice but not compensated.  In order to allow pressure compensated flow control in one direction and full free flow in the opposite direction, Parker offers an internal check valve in the adjustable FC101 cartridge.  Because both versions are tunable and not fully adjustable, the valve will need to be specified with the appropriate flow range for the application. Changes in flow rates are achieved by mechanically varying the spring force acting on a spool that has a fixed orifice and metering compensator. J02E2, J04C2, and J04E2 are fully adjustable pressure compensated flow regulators. In the opposite flow direction, those valves only meter through a fixed orifice and do not compensate. In order to achieve fully adjustable pressure compensated flow control while allowing reverse full flow, the FA101 includes an internal check valve to bypass the compensator and metering orifice.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialConnection SizeConnection TypeBody MaterialDivisionDivisionInstallation TorqueMaximum Operating PressureMaximum Kinematic ViscosityMaximum Inlet Pressure RatingWeightMinimum Operating TemperatureFunctionAdjustment MechanismCavity SizeMaximum Operating TemperatureFor Fluid TypeValve MaterialFlow Rate AccuracyOperating TemperatureFilter Efficiency RatingConfigurationActuation TypeOperation TypeFlow RateMaximum Flow RateFlow Rate Display RangeStandard Flow Rate SettingSeal MaterialAdjustment MechanismConfigurationMaximum Flow RateFlow Rate Display RangeStandard Flow Rate Setting
FC101S300
Quote Required
$129.00
EANitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division16 lb-ft3500 psi45-2000 SSU (6 to 420 cSt)3500 psi0.5 lb-35 °CFlow ControlScrewC10-2+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-30 to +250 °FISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated56 L/min56 L/min2-4.5 Gal/min3 Gal/minNitrileScrewReverse Check15 GAL/MIN, 56 L/MIN2-4.5 GAL/MIN, 7.5-16.9 L/MIN3 GAL/MIN, 11.3 L/MIN
FC101S300V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 Nm3500 psi45-2000 SSU (6 to 420 cSt)245 bar0.5 lb-15 °FFlow ControlScrewC10-2+204 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-26 to +204 °CISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15 Gal/min56 L/min7.5-16.9 L/min11.3 L/minFluorocarbonScrewReverse Check15 GAL/MIN, 56 L/MIN2-4.5 GAL/MIN, 7.5-16.9 L/MIN3 GAL/MIN, 11.3 L/MIN
FC101S600
Quote Required
$129.00
EANitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 Nm245 bar45-2000 SSU (6 to 420 cSt)3500 psi0.23 kg-35 °CFlow ControlScrewC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-35 to +121 °CISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15 Gal/min15 Gal/min4-8 Gal/min6 Gal/minNitrileScrewReverse Check15 GAL/MIN, 56 L/MIN4-8 GAL/MIN, 15-30 L/MIN6 GAL/MIN, 22.5 L/MIN
FC101S600V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 Nm3500 psi45-2000 SSU (6 to 420 cSt)3500 psi0.23 kg-15 °FFlow ControlScrewC10-2+204 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-26 to +204 °CISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated56 L/min15 Gal/min4-8 Gal/min6 Gal/minFluorocarbonScrewReverse Check15 GAL/MIN, 56 L/MIN4-8 GAL/MIN, 15-30 L/MIN6 GAL/MIN, 22.5 L/MIN
FC101T050
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division16 lb-ft245 bar45-2000 SSU (6 to 420 cSt)3500 psi0.5 lb-30 °FFlow ControlTamper ResistantC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-30 to +250 °FISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated56 L/min56 L/min0.3-1 Gal/min0.5 Gal/minNitrileTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN0.3-1 GAL/MIN, 1.1-3.8 L/MIN0.5 GAL/MIN, 1.9 L/MIN
FC101T050V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlTamper ResistantC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-15 to +400ISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15150.3-1 gal/min This is the regulated flow range (min - max)0.5FluorocarbonTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN0.3-1 GAL/MIN, 1.1-3.8 L/MIN0.5 GAL/MIN, 1.9 L/MIN
FC101T100
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 Nm245 bar45-2000 SSU (6 to 420 cSt)245 bar0.5 lb-35 °CFlow ControlTamper ResistantC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-30 to +250 °FISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15 Gal/min56 L/min0.75-2.2 Gal/min3.8 L/minNitrileTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN0.75-2.2 GAL/MIN, 2.8-8.3 L/MIN1 GAL/MIN, 3.8 L/MIN
FC101T100V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlTamper ResistantC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-15 to +400ISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15150.75-2.2 gal/min This is the regulated flow range (min - max)1FluorocarbonTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN0.75-2.2 GAL/MIN, 2.8-8.3 L/MIN1 GAL/MIN, 3.8 L/MIN
FC101T300
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division16 lb-ft3500 psi45-2000 SSU (6 to 420 cSt)245 bar0.5 lb-30 °FFlow ControlTamper ResistantC10-2+121 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-30 to +250 °FISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15 Gal/min56 L/min7.5-16.9 L/min11.3 L/minNitrileTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN2-4.5 GAL/MIN, 7.5-16.9 L/MIN3 GAL/MIN, 11.3 L/MIN
FC101T300V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlTamper ResistantC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-15 to +400ISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15152-4.5 gal/min This is the regulated flow range (min - max)3FluorocarbonTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN2-4.5 GAL/MIN, 7.5-16.9 L/MIN3 GAL/MIN, 11.3 L/MIN
FC101T600
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division16 lb-ft245 bar45-2000 SSU (6 to 420 cSt)245 bar0.5 lb-30 °FFlow ControlTamper ResistantC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-30 to +250 °FISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15 Gal/min15 Gal/min15-30 L/min22.5 L/minNitrileTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN4-8 GAL/MIN, 15-30 L/MIN6 GAL/MIN, 22.5 L/MIN
FC101T600V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlTamper ResistantC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelN/A-15 to +400ISO 4406 18/16/13, SAE Class 4Reverse CheckPressure CompensatedManually operated15154-8 gal/min This is the regulated flow range (min - max)6FluorocarbonTamper ResistantReverse Check15 GAL/MIN, 56 L/MIN4-8 GAL/MIN, 15-30 L/MIN6 GAL/MIN, 22.5 L/MIN
FR032010
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division13 lb-ft345 bar45-2000 SSU (6 to 420 cSt)5000 psi0.045 lb-15 °FFlow ControlTamper ResistantES10436+204 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-15 to +400 °FISO 4406 18/16/13, SAE Class 4InsertPressure CompensatedAutomatic0.3 Gal/min1.13 L/minN/A Gal/min0.1 Gal/minFluorocarbonFixedInsert0.3 GAL/MIN, 1.13 L/MINN/A0.1 GAL/MIN, 0.38 L/MIN
FR032020
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division18 Nm345 bar45-2000 SSU (6 to 420 cSt)345 bar0.045 lb-26 °CFlow ControlTamper ResistantES10436+400 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-15 to +400 °FISO 4406 18/16/13, SAE Class 4InsertPressure CompensatedAutomatic0.3 Gal/min0.3 Gal/minN/A Gal/min0.76 L/minFluorocarbonFixedInsert0.3 GAL/MIN, 1.13 L/MINN/A0.2 GAL/MIN, 0.76 L/MIN
FR032030
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division13 lb-ft345 bar45-2000 SSU (6 to 420 cSt)5000 psi0.045 lb-26 °CFlow ControlTamper ResistantES10436+204 °CMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-26 to +204 °CISO 4406 18/16/13, SAE Class 4InsertPressure CompensatedAutomatic0.3 Gal/min1.13 L/minN/A Gal/min1.13 L/minFluorocarbonFixedInsert0.3 GAL/MIN, 1.13 L/MINN/A0.3 GAL/MIN, 1.13 L/MIN
FR101F100
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 (Aluminum), 65 (Steel) Nm245 bar45-2000 SSU (6 to 420 cSt)3500 psi0.5 lb-35 °CFlow ControlFixedC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel20%-30 to +250 °FISO 4406 18/16/13, SAE Class 4Partial Reverse FlowPressure CompensatedAutomatic6 Gal/min6 Gal/minN/A Gal/min3.8 L/minNitrileFixedPartial Reverse Flow6 GAL/MIN, 22.5 L/MINN/A1 GAL/MIN, 3.8 L/MIN
FR101F100V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16 (Aluminum), 48 (Steel)350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlFixedC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel20%-15 to +400ISO 4406 18/16/13, SAE Class 4Partial Reverse FlowPressure CompensatedAutomatic66N/A gal/min This is the regulated flow range (min - max)1FluorocarbonFixedPartial Reverse Flow6 GAL/MIN, 22.5 L/MINN/A1 GAL/MIN, 3.8 L/MIN
FR101F200
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division22 (Aluminum), 65 (Steel) Nm3500 psi45-2000 SSU (6 to 420 cSt)3500 psi0.23 kg-35 °CFlow ControlFixedC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-35 to +121 °CISO 4406 18/16/13, SAE Class 4Partial Reverse FlowPressure CompensatedAutomatic22.5 L/min22.5 L/minN/A Gal/min2 Gal/minNitrileFixedPartial Reverse Flow6 GAL/MIN, 22.5 L/MINN/A2 GAL/MIN, 7.5 L/MIN
FR101F200V
Quote Required
TBD
Fluorocarbonn/an/an/aHydraulic Valve Systems DivisionHydraulic Systems Division16 (Aluminum), 48 (Steel)350045-2000 SSU (6 to 420 cSt)35000.5-15Flow ControlFixedC10-2+400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-15 to +400ISO 4406 18/16/13, SAE Class 4Partial Reverse FlowPressure CompensatedAutomatic66N/A gal/min This is the regulated flow range (min - max)2FluorocarbonFixedPartial Reverse Flow6 GAL/MIN, 22.5 L/MINN/A2 GAL/MIN, 7.5 L/MIN
FR101F300
Quote Required
TBD
Nitrilen/an/an/aHydraulic Cartridge Systems DivisionHydraulic Systems Division16 (Aluminum), 48 (Steel) lb-ft245 bar45-2000 SSU (6 to 420 cSt)3500 psi0.5 lb-35 °CFlow ControlFixedC10-2+250 °FMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel15%-35 to +121 °CISO 4406 18/16/13, SAE Class 4Partial Reverse FlowPressure CompensatedAutomatic6 Gal/min6 Gal/minN/A Gal/min3 Gal/minNitrileFixedPartial Reverse Flow6 GAL/MIN, 22.5 L/MINN/A3 GAL/MIN, 11.3 L/MIN