OIL-X 'Point Of Use' Oil Vapour Reduction Filters
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Oil vapour is oil in a gaseous form and will pass straight through coalescing filters which are designed to remove liquid oil and oil aerosols, Parker recommend activated carbon adsorption filter technology to reduce oil vapour.
OIL-X 'point of use' oil vapour reduction filters are available in two options: the Grade ACS single stage adsorption filter and Grade AC double stage filter - Grade AC consists of both coalescing and adsorption filter elements combined into one housing. OIL-X Grades ACS and AC are used for smaller flow rate applications and applications where more frequent element changes can be tolerated.
Features/Benefits
• High efficiency 'point of use' filters
• Protects downstream equipment and processes
• Provides high quality, clean, oil free compressed air to international standards
• Reduced cost of ownership
• Enhanced health and safety
• Suitable for all types of air compressor and compatible with all compressor lubricants
• Manufactured in accordance with ISO9001
Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
Please note: The lifetime of the activated carbon material can vary and is dependent on the contamination type and quantity and also on the humidity of the compressed air.
Read More...OIL-X 'point of use' oil vapour reduction filters are available in two options: the Grade ACS single stage adsorption filter and Grade AC double stage filter - Grade AC consists of both coalescing and adsorption filter elements combined into one housing. OIL-X Grades ACS and AC are used for smaller flow rate applications and applications where more frequent element changes can be tolerated.
Features/Benefits
• High efficiency 'point of use' filters
• Protects downstream equipment and processes
• Provides high quality, clean, oil free compressed air to international standards
• Reduced cost of ownership
• Enhanced health and safety
• Suitable for all types of air compressor and compatible with all compressor lubricants
• Manufactured in accordance with ISO9001
Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
Please note: The lifetime of the activated carbon material can vary and is dependent on the contamination type and quantity and also on the humidity of the compressed air.
| Action | Part No. | Availability | Partner Available | Price | Brand | Technology | Division | Industry | Application | Division | Micron Rating | Weight | Product Type | Depth | Width | Materials of Construction | Product Series | Operating Temperature | Height | Filter Type | Compatible Element | Operating Pressure | Specifications Met | Residual Oil Content | Pressure Differential | Element Change Interval | Connection Type | Port Size | Drain | Filter Stages | Maximum Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AC010AGFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 12.3 inch | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 11 psi Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ¼ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010AGFX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ¼ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010AGMI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 290 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ¼ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010AGMX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 | 0.8 | Compressed Air Filter | 65.0 | 76.0 | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 | 311.0 | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 20 | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Saturated, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ¼ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010ANFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 65.0 mm | 3 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 12.3 inch | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | NPT | ¼ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010BGFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 12.3 inch | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Saturated, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010BGFX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 12.3 inch | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010BGMI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 65.0 mm | 3 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 290 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 11 psi Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010BGMX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 | 0.8 | Compressed Air Filter | 65.0 | 76.0 | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 | 311.0 | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 20 | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010BNFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 2.6 inch | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | NPT | ⅜ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010CGFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.8 lb | Compressed Air Filter | 2.6 inch | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 16 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 11 psi Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ½ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010CGFX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 2.6 inch | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 11 psi Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ½ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010CGMI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 65.0 mm | 3 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 20 barg | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ½ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010CGMX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 | 0.8 | Compressed Air Filter | 65.0 | 76.0 | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 | 311.0 | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 1 to 20 | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | BSPP | ½ inch | Manual | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC010CNFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 0.8 kg | Compressed Air Filter | 65.0 mm | 76.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 311.0 mm | Oil Vapour Reduction | P010AA and 010AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P010AA:<br/> 12 Months<br/><br/>010AC:<br/> When oil vapour is detected | NPT | ½ inch | Automatic Float | Double Stage | 22 m³/h @ 7 barg (13 cfm @ 102 psig) | ||
| AC015BGFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 3.5 lb | Compressed Air Filter | 3.3 inch | 97.0 mm | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 °C | 18.7 inch | Oil Vapour Reduction | P015AA and 015AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P015AA:<br/> 12 Months<br/><br/>015AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Automatic Float | Double Stage | 46 m³/h @ 7 barg (27 cfm @ 102 psig) | ||
| AC015BGFX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.6 kg | Compressed Air Filter | 84.0 mm | 3.8 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 18.7 inch | Oil Vapour Reduction | P015AA and 015AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | 11 psi Initial Dry, 100% Flow | P015AA:<br/> 12 Months<br/><br/>015AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Automatic Float | Double Stage | 46 m³/h @ 7 barg (27 cfm @ 102 psig) | ||
| AC015BGMI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 3.5 lb | Compressed Air Filter | 84.0 mm | 3.8 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 474.0 mm | Oil Vapour Reduction | P015AA and 015AC<br/>Requires Both | 15 to 290 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P015AA:<br/> 12 Months<br/><br/>015AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Manual | Double Stage | 46 m³/h @ 7 barg (27 cfm @ 102 psig) | ||
| AC015BGMX | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 | 1.6 | Compressed Air Filter | 84.0 | 97.0 | Die Cast Aluminium | OIL-X Grades ACS and AC | 2 to 30 | 474.0 | Oil Vapour Reduction | P015AA and 015AC<br/>Requires Both | 1 to 20 | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P015AA:<br/> 12 Months<br/><br/>015AC:<br/> When oil vapour is detected | BSPP | ⅜ inch | Manual | Double Stage | 46 m³/h @ 7 barg (27 cfm @ 102 psig) | ||
| AC015BNFI | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | Compressed Air and Nitrogen Gas Applications | Gas Separation and Filtration Division EMEA | down to 0.01 MICRON | 1.6 kg | Compressed Air Filter | 84.0 mm | 3.8 inch | Die Cast Aluminium | OIL-X Grades ACS and AC | 35 to 86 °F | 18.7 inch | Oil Vapour Reduction | P015AA and 015AC<br/>Requires Both | 15 to 232 psig | Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II | Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F) | < 773 mbar Initial Dry, 100% Flow | P015AA:<br/> 12 Months<br/><br/>015AC:<br/> When oil vapour is detected | NPT | ⅜ inch | Automatic Float | Double Stage | 46 m³/h @ 7 barg (27 cfm @ 102 psig) |