The MXLE compressed air dryer has been specifically designed to provide all of the benefits of an MX heatless adsorption dryer with the additional benefits of lower energy costs and lower environmental impact via its vacuum regeneration method, allowing around 17% more of the generated clean, dry compressed air to be used across the plant.

The MXLE compressed air dryer Includes pre and post OIL-X filters which have been third party tested in accordance with ISO12500-1 / ISO8573-4 resulting in delivered air quality in accordance with ISO8573-1.

The modular construction allows greater flexibility; like MX, models can be multi-banked to provide extra compressed air drying capacity should demand increase. This distinctive feature allows 100% stand by at a fraction of the cost of a traditional twin tower dryer and also allows individual dryers to be easily isolated for routine service work, whilst maintaining the plants clean, dry air supply. MXLE also offers the extra security of a full back up mode, in the unlikely event of a fault occurring with the vacuum pump, the dryer can be operated in full heatless mode to keep the plant operational.

At full load conditions, MXLE has an average 60% lower energy consumption than a comparative heatless dryer and an average 39% lower energy consumption than a comparative heat regenerative dryer. These energy savings increase in periods of low air demand due to the integrated Energy Saving Technology (EST) which is fitted as standard.

The compressed air dryer is manufactured with materials of construction that meet FDA Title 21 and are EC1935-2004 exempt; meaning the MXLE compressed air dyer is ideally suited for food, beverage and pharmaceutical industries and applications.

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceTechnologyOperating TemperatureConnection TypeOperating PressureProduct StyleApplicationHeightIngress Protection RatingDivisionElectrical RequirementsDivisionProduct SeriesProduct TypeWidthNoise LevelIndustryWeightSpecifications MetBrandDepthAmbient TemperatureISO GradeFlow RatePort SizePressure Dew Point
MXLE102C
Quote Required
TBD
Filtration41 to 122 °FBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications1647.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer793.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental583 lbPED 2014/68/EU Fluid Group IIParker21.7 inch55.0 °C MaximumClass 2.2.2 or Class 2.3.2408 m³/h @7 barg (240 cfm @102 psig)2 inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE102C-70
Quote Required
TBD
Filtration5 to 50 °CBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications64.8 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer793.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental583 lbPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.1.2408 m³/h @7 barg (240 cfm @102 psig)2 inch-70°C (-100°F)
MXLE103
Quote Required
TBD
Filtration5 to 50 °CBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer962.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental385 kgPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.2.2 or Class 2.3.2765 m³/h @7 barg (240 cfm @102 psig)2 inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE103-70
Quote Required
TBD
Filtration5 to 50 °CBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer962.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental847 lbPED 2014/68/EU Fluid Group IIParker550.0 mm131.0 °F MaximumClass 2.1.2765 m³/h @7 barg (240 cfm @102 psig)2 inch-70°C (-100°F)
MXLE103C
Quote Required
TBD
Filtration5 to 50 °CBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications64.8 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer962.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental346 kgPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.2.2 or Class 2.3.2612 m³/h @7 barg (240 cfm @102 psig)2 inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE103C-70
Quote Required
TBD
Filtration41 to 122 °FBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications1647.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer962.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental761 lbPED 2014/68/EU Fluid Group IIParker21.7 inch55.0 °C MaximumClass 2.1.2612 m³/h @7 barg (240 cfm @102 psig)2 inch-70°C (-100°F)
MXLE104
Quote Required
TBD
Filtration5 to 50 °CBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer1131.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1056 lbPED 2014/68/EU Fluid Group IIParker550.0 mm55.0 °C MaximumClass 2.2.2 or Class 2.3.21020 m³/h @7 barg (240 cfm @102 psig)2½ inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE104-70
Quote Required
TBD
Filtration5 to 50 °CBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications74.5 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer44.6 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1056 lbPED 2014/68/EU Fluid Group IIParker550.0 mm55.0 °C MaximumClass 2.1.21020 m³/h @7 barg (240 cfm @102 psig)2½ inch-70°C (-100°F)
MXLE105
Quote Required
TBD
Filtration41 to 122 °FBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer51.2 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental573 kgPED 2014/68/EU Fluid Group IIParker21.7 inch55.0 °C MaximumClass 2.2.2 or Class 2.3.21275 m³/h @7 barg (240 cfm @102 psig)2½ inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE105-70
Quote Required
TBD
Filtration41 to 122 °FBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications74.5 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer51.2 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1261 lbPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.1.21275 m³/h @7 barg (240 cfm @102 psig)2½ inch-70°C (-100°F)
MXLE106
Quote Required
TBD
Filtration41 to 122 °FBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications74.5 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer57.9 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental667 kgPED 2014/68/EU Fluid Group IIParker550.0 mm131.0 °F MaximumClass 2.2.2 or Class 2.3.21530 m³/h @7 barg (240 cfm @102 psig)2½ inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE106-70
Quote Required
TBD
Filtration5 to 50 °CBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer1469.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental667 kgPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.1.21530 m³/h @7 barg (240 cfm @102 psig)2½ inch-70°C (-100°F)
MXLE107
Quote Required
TBD
Filtration41 to 122 °FBSPP58 to 190 psigHeatless Low Energy - Vacuum AssistedCompressed Air Applications74.5 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer64.6 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1674 lbPED 2014/68/EU Fluid Group IIParker21.7 inch131.0 °F MaximumClass 2.2.2 or Class 2.3.21785 m³/h @7 barg (240 cfm @102 psig)2½ inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE107-70
Quote Required
TBD
Filtration41 to 122 °FBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications74.5 inchIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer64.6 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1674 lbPED 2014/68/EU Fluid Group IIParker550.0 mm131.0 °F MaximumClass 2.1.21785 m³/h @7 barg (240 cfm @102 psig)2½ inch-70°C (-100°F)
MXLE108
Quote Required
TBD
Filtration5 to 50 °CBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer71.2 inch< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1881 lbPED 2014/68/EU Fluid Group IIParker21.7 inch55.0 °C MaximumClass 2.2.2 or Class 2.3.22040 m³/h @7 barg (240 cfm @102 psig)2½ inch-40°C (-40°F) or -20°C (-4°F) Option
MXLE108-70
Quote Required
TBD
Filtration41 to 122 °FBSPP4 to 13 bargHeatless Low Energy - Vacuum AssistedCompressed Air Applications1892.0 mmIP55 Indoor Use OnlyGas Separation and Filtration Division EMEAStandard: 400V +/-10% 3PH 50Hz<br/>Option: 460V +/-10% 3PH 60HzGas Separation and Filtration Division EMEAMXLECompressed Air Dryer1807.0 mm< 75 dBAIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1881 lbPED 2014/68/EU Fluid Group IIParker21.7 inch55.0 °C MaximumClass 2.1.22040 m³/h @7 barg (240 cfm @102 psig)2½ inch-70°C (-100°F)