- Availability & Price
- Search SKU
Filter by attributes
- Additional Protection Included
- Hydraulic Circuit
- Kit Type
- Maximum Cooling Capacity
- Operating Environment
- Options
- Output Water Temperature Range
- Power Supply Voltage
- Pump Type
- Water Sensor Option
Filter by manufacturer
Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Biogas is primarily composed of methane and carbon dioxide with smaller amounts of hydrogen sulphide and ammonia. Trace amounts of other gases like hydrogen, nitrogen or carbon monoxide are also present in the biogas. Usually the mixed gas is saturated with water-vapour and may contain dirt particles. For biogas as a fuel, most of the impurities have to be removed, as they can cause contamination, deposits and damage to equipment. In particular, biogas needs to be dried by cooling it to temperatures close to 5°C (41°F), using water-cooled heat exchangers fed by water chillers. Hyperchill Bioenergy is a key component in this biogas treatment process.
Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.
Features:
• Special protective treatment of condensers and copper piping
• Pump and tank installed inside the chiller
• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime
• Designed to provide cooling water where low temperature water is required as standard
• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications
• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low
• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models
Benefits:
• Compact and easy to install solution
• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites
• High working limits and low running costs
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.
Features:
• Special protective treatment of condensers and copper piping
• Pump and tank installed inside the chiller
• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime
• Designed to provide cooling water where low temperature water is required as standard
• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications
• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low
• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models
Benefits:
• Compact and easy to install solution
• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites
• High working limits and low running costs
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Port Type | Division | Division | Port Size | Brand | Refrigerant Type | Operating Temperature | Height | Product Style | Depth | Product Type | Technology | Noise Level | Ambient Temperature | Compressor Included | Number of Axial Fans | Width | Application | Tank Capacity | Product Series | Cooling Method | Water Sensor Option | Power Supply Voltage | Maximum Cooling Capacity | Additional Protection Included | Kit Type | Options | Pump Type | Hydraulic Circuit | Operating Environment | Output Water Temperature Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ICE076B4003501P15FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE076B4003501P30FF000000 | Quote Required | TBD | Gas Separation and Filtration Division EMEA | No Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Selected | Single Pump 3 bar | With Tank | No Low Ambient | Without Close Control | ||||||||||||||||||||||
| ICE076B4003501P30FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 5 to 30 °C | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE076B4003501P30FF0LALW0 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE076B4003502P30FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 2200 mm | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Dual Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE076B4003502P30FF0LALW0 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 5 to 30 °C | 1984 mm | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | Low Water | 400V/3Ph/50Hz | 76.0 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Dual Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE090B4003501P15FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 1984 mm | Pressurized Closed Hydraulic Circuit | 2200 mm | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 90.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE090B4003501P30FF000000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 1984 mm | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 90.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | No Low Ambient | Without Close Control | ||
| ICE090B4003501P30FF0L2000 | Quote Required | TBD | Gas Separation and Filtration Division EMEA | No Low Water | 400V/3Ph/50Hz | 90.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Selected | Single Pump 3 bar | With Tank | Low Ambient -20°C Fan Step Control) | Without Close Control | ||||||||||||||||||||||
| ICE090B4003501P30FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 90.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE090B4003501P30FFCLA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 90.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | Low Ambient -10°C | Close Control +/- 0.5°C | ||
| ICE116B4003501P15FF000000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | No Low Ambient | Without Close Control | ||
| ICE116B4003501P15FF0L2000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 1984 mm | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -20°C | Without Close Control | ||
| ICE116B4003501P15FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE116B4003501P15FF0LALW0 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 2200 mm | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE116B4003501P30FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 59.1 inch | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 3 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE116B4003502P50FF0LALW0 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 41 to 86 °F | 1984 mm | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 113 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | Low Water | 400V/3Ph/50Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Dual Pump 5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE116B4603601P15FF0LA000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2 inch | Hiross | R407c | 5 to 30 °C | 78.1 inch | Pressurized Closed Hydraulic Circuit | 86.6 inch | Production Process Water Chiller | Thermal and Power Management | 58 dBA | 45 | Hermetic Scroll | 3 | 1500 mm | Precision Cooling of Biogas Cooling Fluids | 500 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 460V/3Ph/60Hz | 115.5 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control | ||
| ICE150B4003501P15FF000000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2-1/2 inch | Hiross | R407c | 41 to 86 °F | 90.5 inch | Pressurized Closed Hydraulic Circuit | 118.1 inch | Production Process Water Chiller | Thermal and Power Management | 62 dBA | 113 | Hermetic Scroll | 2 | 1287 mm | Precision Cooling of Biogas Cooling Fluids | 1000 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | No Low Water | 400V/3Ph/50Hz | 149.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | No Low Ambient | Without Close Control | ||
| ICE150B4003501P15FF000LW0 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 2-1/2 inch | Hiross | R407c | 41 to 86 °F | 90.5 inch | Pressurized Closed Hydraulic Circuit | 118.1 inch | Production Process Water Chiller | Thermal and Power Management | 62 dBA | 45 | Hermetic Scroll | 2 | 50.7 inch | Precision Cooling of Biogas Cooling Fluids | 1000 L | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | Low Water | 400V/3Ph/50Hz | 149.2 kW @ 25°C (63°F) | Without Antifreeze | Not Applicable | No Options Available | Single Pump 1.5 bar | With Tank | Low Ambient -10°C | Without Close Control |