Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Biogas is primarily composed of methane and carbon dioxide with smaller amounts of hydrogen sulphide and ammonia. Trace amounts of other gases like hydrogen, nitrogen or carbon monoxide are also present in the biogas. Usually the mixed gas is saturated with water-vapour and may contain dirt particles. For biogas as a fuel, most of the impurities have to be removed, as they can cause contamination, deposits and damage to equipment. In particular, biogas needs to be dried by cooling it to temperatures close to 5°C (41°F), using water-cooled heat exchangers fed by water chillers. Hyperchill Bioenergy is a key component in this biogas treatment process.
Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.
Features:
• Special protective treatment of condensers and copper piping
• Pump and tank installed inside the chiller
• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime
• Designed to provide cooling water where low temperature water is required as standard
• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications
• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low
• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models
Benefits:
• Compact and easy to install solution
• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites
• High working limits and low running costs
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.
Features:
• Special protective treatment of condensers and copper piping
• Pump and tank installed inside the chiller
• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime
• Designed to provide cooling water where low temperature water is required as standard
• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications
• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low
• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models
Benefits:
• Compact and easy to install solution
• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites
• High working limits and low running costs
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Port Type | Division | Division | Port Size | Brand | Refrigerant Type | Operating Temperature | Product Style | Product Type | Technology | Compressor Included | Application | Product Series | Cooling Method | Number of Axial Fans | Ambient Temperature | Width | Height | Noise Level | Depth | Tank Capacity | Water Sensor Option | Power Supply Voltage | Operating Environment | Additional Protection Included | Options | Pump Type | Hydraulic Circuit | Output Water Temperature Range | Kit Type | Maximum Cooling Capacity | For Fluid Type | Ingress Protection Rating | Weight | Specifications Met | Industry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ICEP030-WBTP1T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 29.8 inch | 1405 mm | < 53 dBA | 47.5 inch | 130 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 29.7 kW @ 25°C (63°F) | |||||||
| ICEP030-WBTP3T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 756 mm | 55.3 inch | < 53 dBA | 47.5 inch | 130 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Without Fill Kit | 29.7 kW @ 25°C (63°F) | |||||||
| ICEP030-WBTP3T0L20000 | Quote Required | TBD | Threaded | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Scroll | Precision Cooling of Low Viscosity Industrial Cooling Fluids | Hyperchill Plus | 2 | 118.4 | 756 mm | 55.3 inch | < 53 dBA | 47.5 inch | 130 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -20°C | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Without Fill Kit | 29.7 kW @ 25°C (63°F) | Water | IP54 | 550 lb | Machinery Directive 2006/42/EC | Biogas | |||
| ICEP030-WBTP5T0L10003 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 29.8 inch | 55.3 inch | < 53 dBA | 1206 mm | 130 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 5 bar | With Tank | Without Close Control | Pressurised Fill Kit | 29.7 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP1T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 33.7 inch | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 40.6 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP1T0L20000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 856 mm | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -20°C | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 40.6 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP3T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 33.7 inch | 1680 mm | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Without Fill Kit | 40.6 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP3T0L10001 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 33.7 inch | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Ambient Manual Fill Kit | 40.6 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP3T0L10001C | Quote Required | TBD | Threaded | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Scroll | Precision Cooling of Low Viscosity Industrial Cooling Fluids | Hyperchill Plus | 2 | 118.4 | 33.7 inch | 66.1 inch | < 53 dBA | 1956 mm | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | Control Panel Cover | Single Pump 3 bar | With Tank | Without Close Control | Ambient Manual Fill Kit | 40.6 kW @ 25°C (63°F) | Water | IP54 | 450 kg | Machinery Directive 2006/42/EC | Biogas | |||
| ICEP040-WBTP3T0L1LW01 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 33.7 inch | 1680 mm | < 53 dBA | 1956 mm | 250 L | Low Water | 400V/3Ph/50Hz | Low Ambient -10°C Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Ambient Manual Fill Kit | 40.6 kW @ 25°C (63°F) | |||||||
| ICEP040-WBTP5T0L100A3 | Quote Required | TBD | Threaded | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Scroll | Precision Cooling of Low Viscosity Industrial Cooling Fluids | Hyperchill Plus | 2 | 48 | 856 mm | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | With Antifreeze | No Options Selected | Single Pump 5 bar | With Tank | Without Close Control | Pressurised Fill Kit | 40.6 kW @ 25°C (63°F) | Water | IP54 | 450 kg | PED 97/23/EC | Plastics | |||
| ICEP050-WBT00T0L20003 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 856 mm | 1680 mm | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -20°C | Without Antifreeze | No Options Selected | No Pump | With Tank | Without Close Control | Pressurised Fill Kit | 49.0 kW @ 25°C (63°F) | |||||||
| ICEP050-WBTP1T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 856 mm | 1680 mm | < 53 dBA | 1956 mm | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 49.0 kW @ 25°C (63°F) | |||||||
| ICEP050-WBTP1T0L10000C | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 856 mm | 66.1 inch | < 53 dBA | 1956 mm | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | Control Panel Cover | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 49.0 kW @ 25°C (63°F) | |||||||
| ICEP050-WBTP1T0L10003 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 33.7 inch | 1680 mm | < 53 dBA | 1956 mm | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Pressurised Fill Kit | 49.0 kW @ 25°C (63°F) | |||||||
| ICEP050-WBTP3T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 33.7 inch | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Without Fill Kit | 49.0 kW @ 25°C (63°F) | |||||||
| ICEP060-WBTP1T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 48 | 856 mm | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 58.3 kW @ 25°C (63°F) | |||||||
| ICEP060-WBTP1T0L10000C | Quote Required | TBD | Threaded | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Scroll | Precision Cooling of Low Viscosity Industrial Cooling Fluids | Hyperchill Plus | 2 | 118.4 | 33.7 inch | 1680 mm | < 53 dBA | 1956 mm | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | With Antifreeze | Control Panel Cover | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 58.3 kW @ 25°C (63°F) | Water | IP54 | 1122 lb | Machinery Directive 2006/42/EC | Electronics | |||
| ICEP060-WBTP1T0L1LW00 | Quote Required | TBD | Threaded | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 41 to 86 °F | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Scroll | Precision Cooling of Low Viscosity Industrial Cooling Fluids | Hyperchill Plus | 2 | 118.4 | 856 mm | 1680 mm | < 53 dBA | 1956 mm | 250 L | Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 1.5 bar | With Tank | Without Close Control | Without Fill Kit | 58.3 kW @ 25°C (63°F) | Water | IP54 | 1122 lb | Machinery Directive 2006/42/EC | Wine | |||
| ICEP060-WBTP3T0L10000 | Quote Required | TBD | BSPP | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | 1-1/2 inch | Hiross | R407c | 5 to 30 °C | Pressurized Closed Hydraulic Circuit | Production Process Water Chiller | Thermal and Power Management | Hermetic Scroll | Precision Cooling of Biogas Cooling Fluids | Hyperchill BioEnergy | BioEnergy & Aggressive Ambients | 2 | 118.4 | 856 mm | 66.1 inch | < 53 dBA | 77.0 inch | 250 L | No Low Water | 400V/3Ph/50Hz | Low Ambient -10°C (Fan Step Control) | Without Antifreeze | No Options Selected | Single Pump 3 bar | With Tank | Without Close Control | Without Fill Kit | 58.3 kW @ 25°C (63°F) |