GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

Picture for category GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker GH series high pressure filters are designed to be ideal for high pressure applications up to 100 bar g. The innovative construction features of the filter housing provide a reliable assembly, as well as simple and safe handling for replacing the filter element. One essential construction feature is the double O-ring seal which protects the housing thread against pollution and humidity and therefore prevents the thread from corrosion. Additionally the second O-ring prevents the filter housing parts from over winding.

By fastening the filter element via its base thread screwed on the tie-rod, this provides the greatest operating safety, even under the pressure pulsations in intermittent operation that are common for high pressure applications.

Highly effective pleated media in four different grades provide an element surface that is four times the size, compared to the conventional wrapped design. The result is a reduced flow speed and efficient separation simultaneously with low pressure drop, thus providing cost reduction during operation with reliable separation performance.

Features
• Optimised flow rates and compact filter housing.

• Improved housing design with double O-ring sealing.

• Threaded rod element fixing.

• Pleated elements.

• Complete filter including filter element and manual drain.

• As an option filters are also available without a drain.

• All filter sizes offer connectors for the installation of calibrated differential pressure gauges.

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionIndustryApplicationDivisionProduct TypeOperating TemperatureElement Change IntervalHeightFilter Efficiency RatingWeightWidthProduct SeriesOperating PressureSpecifications MetResidual Oil ContentPressure DifferentialMaterials of ConstructionMicron RatingDrainFilter TypeConnection TypeFlow RateCompatible ElementOperating Temperature
GH11/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 50 °CWhen oil vapour is detected21.3 inchn/a21.9 kg4.6 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020A2 to 50°C (35 to 122°F)
GH11/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 80 °C12 months or 6000 hours540.0 mm> 90 %21.9 kg116.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRN/ASaturated: < 350 mbar (< 5 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020V2 to 80°C (35 to 176°F)
GH11/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours540.0> 9021.9116.0GH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmNoneDry Particulate1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020V2 to 80°C (35 to 176°F)
GH11/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 176 °F12 months or 6000 hours540.0 mm> 99.9999 %21.9 kg116.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.1 mg/m³ - 0.01 ppm(wDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 0.01 μmManualOil Removal Filter1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020XP2 to 80°C (35 to 176°F)
GH11/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 176 °F12 months or 6000 hours540.0 mm> 99.925 %21.9 kg116.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Saturated: < 370 mbar (< 5.4 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmManualCoalescing & Dry Particulate1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020ZP2 to 80°C (35 to 176°F)
GH11/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours655.0> 99.92521.9116.0GH100100.0 barg MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmNoneCoalescing & Dry Particulate1 inch BSPP1203 m³/hr @ 100 barg (708 cfm @ 1450 psig)2020ZP2 to 80°C (35 to 176°F)
GH12/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 122 °FWhen oil vapour is detected655.0 mmn/a62 lb4.9 inchGH100100.0 barg MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030A2 to 50°C (35 to 122°F)
GH12/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 176 °F12 months or 6000 hours25.8 inch> 90 %62 lb4.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TRN/ASaturated: < 350 mbar (< 5 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030V2 to 80°C (35 to 176°F)
GH12/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours655.0> 9028.3125.0GH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmNoneDry Particulate1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030V2 to 80°C (35 to 176°F)
GH12/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 80 °C12 months or 6000 hours25.8 inch> 99.9999 %62 lb125.0 mmGH1001450.0 psig MaximumPED Fluid Group II, TR0.1 mg/m³ - 0.01 ppm(wSaturated: < 400 mbar (< 5.8 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 0.01 μmManualOil Removal Filter1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030XP2 to 80°C (35 to 176°F)
GH12/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 80 °C12 months or 6000 hours655.0 mm> 99.925 %28.3 kg4.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Saturated: < 370 mbar (< 5.4 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmManualCoalescing & Dry Particulate1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030ZP2 to 80°C (35 to 176°F)
GH12/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours655.0> 99.92528.3125.0GH100100.0 barg MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmNoneCoalescing & Dry Particulate1½ inch BSPP1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig)2030ZP2 to 80°C (35 to 176°F)
GH13/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 50 °CWhen oil vapour is detected35.8 inchn/a86 lb125.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050A2 to 50°C (35 to 122°F)
GH13/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 176 °F12 months or 6000 hours35.8 inch> 90 %39.2 kg125.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050V2 to 80°C (35 to 176°F)
GH13/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours910.0> 9039.2125.0GH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmNoneDry Particulate1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050V2 to 80°C (35 to 176°F)
GH13/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter35 to 176 °F12 months or 6000 hours35.8 inch> 99.9999 %86 lb4.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.1 mg/m³ - 0.01 ppm(wSaturated: < 400 mbar (< 5.8 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 0.01 μmManualOil Removal Filter1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050XP2 to 80°C (35 to 176°F)
GH13/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 80 °C12 months or 6000 hours910.0 mm> 99.925 %86 lb4.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Saturated: < 370 mbar (< 5.4 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmManualCoalescing & Dry Particulate1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050ZP2 to 80°C (35 to 176°F)
GH13/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter2 to 8012 months or 6000 hours910.0> 99.92539.2125.0GH100100.0 barg MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmNoneCoalescing & Dry Particulate1½ inch BSPP2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig)2050ZP2 to 80°C (35 to 176°F)
GH3/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air FilterWhen oil vapour is detected355.0 mmn/a2.8 kg80.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Saturated: n/aHousing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)1050A2 to 50°C (35 to 122°F)
GH3/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEACompressed Air Filter12 months or 6000 hours355.0 mm> 90 %6 lb80.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRN/ASaturated: < 350 mbar (< 5 psi)Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)1050V2 to 80°C (35 to 176°F)