Externally Heated Desiccant Air Dryer - TWP Series

Picture for category Externally Heated Desiccant Air Dryer - TWP Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.

A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.

Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all
operational information

*Optional equipment
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Ambient TemperatureMaximum Operating TemperatureMaximum Operating PressureBrandMinimum Ambient TemperatureCompatible PrefilterInstalled Condensate Drain TypeMaximum Flow RateCompatible After FilterPurge Pressure RateMinimum Operating PressureDepthCompatible Prefilter ElementOptional AccessoriesMaximum Inlet Pressure RatingMinimum Operating TemperatureProduct TypeHeightCompatible After Filter ElementDivisionConnection TypeWidthWeightPressure Dew Point (F)Electrical RequirementsMaximum Flow Rate (cfm)
TWP1001FY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC1000-CDemand Solenoid Drain1699 m3/hourJC1000-FH7080 psi41 inchJE-CC0800Pre and After Filtration100 PSI50 °FCompressed Air – Desiccant102 inchJE-FC0800-HTIndustrial Gas Filtration and Generation Division3" Flg74 inch4195 lb-40460V/3Ph/60Hz1000
TWP1201FY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJLA1603-CDemand Solenoid Drain2038 m3/hourJLA1800-FH8480 psi41 inch(2) JAE3-CPre and After Filtration100 PSI50 °FCompressed Air – Desiccant113 inchJAE4-FHIndustrial Gas Filtration and Generation Division3" Flg74 inch5215 lb-40460V/3Ph/60Hz1200
TWP1501FY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJLA1603-CDemand Solenoid Drain2548 m3/hourJLA1800-FH10580 psi60 inch(2) JAE3-CPre and After Filtration100 PSI50 °FHeated113 inchJAE4-FHIndustrial Gas Filtration and Generation Division3" Flg78 inch7765 lb-40460V/3Ph/60Hz1500
TWP2001FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FJLA2100-CDemand Solenoid Drain3398 m3/hourJLA2600-FH14080 psi60 inch(3) JAE3-CPre and After Filtration100 PSI50 °FCompressed Air – Desiccant110 inch(2) JAE4-FHIndustrial Gas Filtration and Generation Division4" Flg78 inch8565 lb-40460V/3Ph/60Hz2000
TWP201BY21NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0250-CTimed Solenoid Drain340 m3/hourJC0250-FH1480 psi22 inchJE-CC0350Pre and After Filtration100 PSI50 °FCompressed Air – Desiccant85 inchJE-FC0350-HTIndustrial Gas Filtration and Generation Division1 1/2” NPT40 inch920 lb-40240V/1Ph/60Hz200
TWP251BY21NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0250-CTimed Solenoid Drain425 m3/hourJC0250-FH17.580 psi22 inchJE-CC0350Pre and After Filtration100 PSI50 °FHeated85 inchJE-FC0350-HTIndustrial Gas Filtration and Generation Division1 1/2" NPT40 inch1180 lb-40240V/1Ph/60Hz250
TWP2601FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FJLA3200-CDemand Solenoid Drain4417 m3/hourJLA2600-FH18280 psi60 inch(4) JAE3-CPre and After Filtration100 PSI50 °FHeated112 inch(2) JAE4-FHIndustrial Gas Filtration and Generation Division4" Flg96 inch11562 lb-40460V/3Ph/60Hz2600
TWP3001FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FJLA3206-CDemand Solenoid Drain5097 m3/hourJLA3506-FH21080 psi60 inch(4) JAE3-CPre and After Filtration100 PSI50 °FCompressed Air – Desiccant112 inch(3) JAE3-FHIndustrial Gas Filtration and Generation Division6" Flg96 inch12002 lb-40460V/3Ph/60Hz3000
TWP301BY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0350-CTimed Solenoid Drain510 m3/hourJC0350-FH2180 psi27 inchJE-CC0350Pre and After Filtration100 PSI50 °FCompressed Air – Desiccant87 inchJE-FC0350-HTIndustrial Gas Filtration and Generation Division1 1/2" NPT43 inch1370 lb-40460V/3Ph/60Hz300
TWP4001FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FConsult FactoryDemand Solenoid Drain6796 m3/hourConsult Factory28080 psiConsult FactoryConsult FactoryPre and After Filtration100 PSI50 °FCompressed Air – DesiccantConsult Factory inchConsult FactoryIndustrial Gas Filtration and Generation Division6" FlgConsult Factory inchn/a Contact us-40460V/3Ph/60Hz4000
TWP401BY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0450-CTimed Solenoid Drain680 m3/hourJC0450-FH2880 psi27 inchJE-CC0450Pre and After Filtration100 PSI50 °FHeated88 inchJE-FC0450-HTIndustrial Gas Filtration and Generation Division2" NPT47 inch1400 lb-40460V/3Ph/60Hz400
TWP5001FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FConsult FactoryDemand Solenoid Drain8495 m3/hourConsult Factory35080 psiConsult FactoryConsult FactoryPre and After Filtration100 PSI50 °FHeatedConsult Factory inchConsult FactoryIndustrial Gas Filtration and Generation Division6" FlgConsult Factory inchn/a Contact us-40460V/3Ph/60Hz5000
TWP501BY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0625-CTimed Solenoid Drain850 m3/hourJC0625-FH3580 psi27 inchJE-CC0625Pre and After Filtration100 PSI50 °FHeated89 inchJE-FC0625-HTIndustrial Gas Filtration and Generation Division2" NPT50 inch2060 lb-40460V/3Ph/60Hz500
TWP6001FY41NNN
Quote Required
TBD
120 °F120 °F135 psiAirtek40 °FConsult FactoryDemand Solenoid Drain10194 m3/hourConsult Factory42080 psiConsult FactoryConsult FactoryPre and After Filtration100 PSI50 °FCompressed Air – DesiccantConsult Factory inchConsult FactoryIndustrial Gas Filtration and Generation Division6" FlgConsult Factory inchn/a Contact us-40460V/3Ph/60Hz6000
TWP601BY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0625-CTimed Solenoid Drain1019 m3/hourJC0625-FH4280 psi28 inchJE-CC0625Pre and After Filtration100 PSI50 °FCompressed Air – Desiccant92 inchJE-FC0625-HTIndustrial Gas Filtration and Generation Division2" NPT52 inch2350 lb-40460V/3Ph/60Hz600
TWP8001FY41NNN
Quote Required
TBD
120120135Airtek40Consult FactoryDemand Solenoid Drain13592Consult Factory56080Consult FactoryConsult FactoryPre and After Filtration10050Compressed Air – DesiccantConsult FactoryConsult FactoryIndustrial Gas Filtration and Generation Division8" FlgConsult Factoryn/a Contact us-40460V/3Ph/60Hz8000
TWP801BY41NNN
Quote Required
TBD
120 °F120 °F150 psiAirtek40 °FJC0800-CTimed Solenoid Drain1359 m3/hourJC0800-FH5680 psi35 inchJE-CC0800Pre and After Filtration100 PSI50 °FHeated93 inchJE-FC0800-HTIndustrial Gas Filtration and Generation Division2" NPT63 inch3035 lb-40460V/3Ph/60Hz800