- Availability & Price
- Search SKU
Filter by attributes
- Electrical Requirements
- Flow Rate
- Optional Accessories
- Port Size
Filter by manufacturer
Breathing Star BSP-MT 1-8 Industrial and Medical Breathing Air System
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker BSP-MT 1-8 industrial and medical breathing air systems combine a heatless adsorption dryer with integral purification and catalytic stages, designed to treat compressed air reliably and efficiently to meet the medical breathing air requirements of the European Pharmacopoeia and other international breathing air standards. Equipped with integrated high efficiency OIL-X pre- and after filtration they are sized for flow rates of up to 139 m³/h @ 13 barg.
BSP-MT 1-8 breathing air systems operate a fixed, timed changeover cycle between the dryer's two specially filled twin-vessels. Continuous, uninterrupted operation is maintained utilising pressure swing adsorption technology together with individually operated main and exhaust valves.
Where the application requires additional monitoring, the installation of a dew point sensor is available as an option. The chosen pressure dew point setting allows the changeover time of the individual vessels to be adjusted to meet operating requirements whilst providing reliable monitoring of the dryer’s performance.
Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...BSP-MT 1-8 breathing air systems operate a fixed, timed changeover cycle between the dryer's two specially filled twin-vessels. Continuous, uninterrupted operation is maintained utilising pressure swing adsorption technology together with individually operated main and exhaust valves.
Where the application requires additional monitoring, the installation of a dew point sensor is available as an option. The chosen pressure dew point setting allows the changeover time of the individual vessels to be adjusted to meet operating requirements whilst providing reliable monitoring of the dryer’s performance.
Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Specifications Met | Weight | Brand | Width | Operating Temperature | Division | Product Series | Pressure Dew Point | Compatible After Filter | Product Type | Ambient Temperature | Application | Height | Connection Type | Technology | Noise Level | Ingress Protection Rating | Depth | Operating Pressure | ISO Grade | Industry | Compatible Prefilter | Flow Rate | Optional Accessories | Electrical Requirements | Port Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| K1/16BP3-G115M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 16.5 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 403.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 13 m³/h @ 13 barg (8 cfm @ 189 psig) | None | 115V 1ph 50/60Hz | ¼ inch | ||
| K1/16BP3-G115MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 16.5 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 403.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 13 m³/h @ 13 barg (8 cfm @ 189 psig) | Dew Point Sensor | 115V 1ph 50/60Hz | ¼ inch | ||
| K1/16BP3-G230M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 36.4 lb | Parker | 22.6 inch | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 403.0 mm | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 13 m³/h @ 13 barg (8 cfm @ 189 psig) | None | 230V 1ph 50/60Hz | ¼ inch | ||
| K1/16BP3-G230MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 36.4 lb | Parker | 22.6 inch | 5 to 50 °C | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 403.0 mm | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 216.0 mm | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 13 m³/h @ 13 barg (8 cfm @ 189 psig) | Dew Point Sensor | 230V 1ph 50/60Hz | ¼ inch | ||
| K2/16BP3-G115M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 21.5 | Parker | 22.6 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 578.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 24 m³/h @ 13 barg (14 cfm @ 189 psig) | None | 115V 1ph 50/60Hz | ¼ inch | ||
| K2/16BP3-G115MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 21.5 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 578.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 24 m³/h @ 13 barg (14 cfm @ 189 psig) | Dew Point Sensor | 115V 1ph 50/60Hz | ¼ inch | ||
| K2/16BP3-G230M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 21.5 kg | Parker | 575.0 mm | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 578.0 mm | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 216.0 mm | 4 to 16 barg | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 24 m³/h @ 13 barg (14 cfm @ 189 psig) | None | 230V 1ph 50/60Hz | ¼ inch | ||
| K2/16BP3-G230MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 47.4 lb | Parker | 575.0 mm | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 23 inch | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 24 m³/h @ 13 barg (14 cfm @ 189 psig) | Dew Point Sensor | 230V 1ph 50/60Hz | ¼ inch | ||
| K3/16BP3-G115M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 29 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 828.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 40 m³/h @ 13 barg (24 cfm @ 189 psig) | None | 115V 1ph 50/60Hz | ¼ inch | ||
| K3/16BP3-G115MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 29 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 828.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 40 m³/h @ 13 barg (24 cfm @ 189 psig) | Dew Point Sensor | 115V 1ph 50/60Hz | ¼ inch | ||
| K3/16BP3-G230M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 63.9 lb | Parker | 22.6 inch | 5 to 50 °C | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 °C | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 33 inch | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 40 m³/h @ 13 barg (24 cfm @ 189 psig) | None | 230V 1ph 50/60Hz | ¼ inch | ||
| K3/16BP3-G230MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 29 kg | Parker | 22.6 inch | 5 to 50 °C | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 °C | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 33 inch | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 40 m³/h @ 13 barg (24 cfm @ 189 psig) | Dew Point Sensor | 230V 1ph 50/60Hz | ¼ inch | ||
| K4/16BP3-G115M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 36.0 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1078.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 56 m³/h @ 13 barg (33 cfm @ 189 psig) | None | 115V 1ph 50/60Hz | ¼ inch | ||
| K4/16BP3-G115MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 36.0 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1078.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 56 m³/h @ 13 barg (33 cfm @ 189 psig) | Dew Point Sensor | 115V 1ph 50/60Hz | ¼ inch | ||
| K4/16BP3-G230M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 79.4 lb | Parker | 22.6 inch | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1078.0 mm | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 56 m³/h @ 13 barg (33 cfm @ 189 psig) | None | 230V 1ph 50/60Hz | ¼ inch | ||
| K4/16BP3-G230MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 79.4 lb | Parker | 575.0 mm | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX010A (Included)<br/>OIL-X AAPX010A (Option) | Breathing Air Purifier | 50.0 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1078.0 mm | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 216.0 mm | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX010A and AAPX010A (Included) | 56 m³/h @ 13 barg (33 cfm @ 189 psig) | Dew Point Sensor | 230V 1ph 50/60Hz | ¼ inch | ||
| K6/16BP3-G115M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 75 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1133.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX015C and AAPX015C (Included) | 90 m³/h @ 13 barg (53 cfm @ 189 psig) | None | 115V 1ph 50/60Hz | ½ inch | ||
| K6/16BP3-G115MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 75 | Parker | 575.0 | 5 to 50 | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | Breathing Air Purifier | 50.0 °C Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 1133.0 | BSPP | Filtration | < 75 | IP65 Indoor Use Only | 216.0 | 4 to 16 | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX015C and AAPX015C (Included) | 90 m³/h @ 13 barg (53 cfm @ 189 psig) | Dew Point Sensor | 115V 1ph 50/60Hz | ½ inch | ||
| K6/16BP3-G230M | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 75 kg | Parker | 22.6 inch | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40 °C | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 45 inch | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 8.5 inch | 4 to 16 barg | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX015C and AAPX015C (Included) | 90 m³/h @ 13 barg (53 cfm @ 189 psig) | None | 230V 1ph 50/60Hz | ½ inch | ||
| K6/16BP3-G230MT | Quote Required | TBD | PED 2014/68/EU Fluid Group II | 165.4 lb | Parker | 22.6 inch | 41 to 122 °F | Gas Separation and Filtration Division EMEA | BSP-MT 1-8 | -40.0 °F | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | Breathing Air Purifier | 122.0 °F Maximum | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 45 inch | BSPP | Filtration | < 75 dBA | IP65 Indoor Use Only | 216.0 mm | 58 to 232 psig | ISO8573-1:2010 Class 2.2.1 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | OIL-X AOPX015C and AAPX015C (Included) | 90 m³/h @ 13 barg (53 cfm @ 189 psig) | Dew Point Sensor | 230V 1ph 50/60Hz | ½ inch |
- 1