- Availability & Price
- Search SKU
Filter by attributes
- Electrical Requirements
- Flow Rate
- Optional Accessories
- Port Size
Filter by manufacturer
Recently viewed products
-
Parker 21-10110-200-11 - Steelflow Pleated Mesh Filter Cartridge | 316L Stainless Steel Cartridge for Microfiltration Applications -
Parker 21-10110-010-12 - Steelflow Pleated Mesh Filter Cartridge | 316L Stainless Steel Cartridge for Microfiltration Applications -
Parker 4LFE6-2-2F-WSB - FULFLO FE MULTI-CARTRIDGE FILTER VESSEL | CARBON STEEL, 304L & 316L STAINLESS STEEL, ASME CODE DESIGN FOR LIQUID/GAS FILTRATION
Breathing Star BSP-MT 1-8 Industrial and Medical Breathing Air System
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker BSP-MT 1-8 industrial and medical breathing air systems combine a heatless adsorption dryer with integral purification and catalytic stages, designed to treat compressed air reliably and efficiently to meet the medical breathing air requirements of the European Pharmacopoeia and other international breathing air standards. Equipped with integrated high efficiency OIL-X pre- and after filtration they are sized for flow rates of up to 139 m³/h @ 13 barg.
BSP-MT 1-8 breathing air systems operate a fixed, timed changeover cycle between the dryer's two specially filled twin-vessels. Continuous, uninterrupted operation is maintained utilising pressure swing adsorption technology together with individually operated main and exhaust valves.
Where the application requires additional monitoring, the installation of a dew point sensor is available as an option. The chosen pressure dew point setting allows the changeover time of the individual vessels to be adjusted to meet operating requirements whilst providing reliable monitoring of the dryer’s performance.
Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...BSP-MT 1-8 breathing air systems operate a fixed, timed changeover cycle between the dryer's two specially filled twin-vessels. Continuous, uninterrupted operation is maintained utilising pressure swing adsorption technology together with individually operated main and exhaust valves.
Where the application requires additional monitoring, the installation of a dew point sensor is available as an option. The chosen pressure dew point setting allows the changeover time of the individual vessels to be adjusted to meet operating requirements whilst providing reliable monitoring of the dryer’s performance.
Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Depth | Compatible Prefilter | Weight | Connection Type | Noise Level | Technology | Compatible After Filter | Ingress Protection Rating | Height | ISO Grade | Operating Pressure | Industry | Brand | Specifications Met | Division | Width | Pressure Dew Point | Product Type | Operating Temperature | Product Series | Application | Ambient Temperature | Optional Accessories | Port Size | Flow Rate | Electrical Requirements |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| K7/16BP3-G115M | Quote Required | TBD | 300.0 | OIL-X AOPX015C and AAPX015C (Included) | 85 | BSPP | < 75 | Filtration | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | IP65 Indoor Use Only | 1358.0 | ISO8573-1:2010 Class 2.2.1 | 4 to 16 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 748.0 | -40 | Breathing Air Purifier | 5 to 50 | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 50.0 °C Maximum | None | ½ inch | 116 m³/h @ 13 barg (68 cfm @ 189 psig) | 115V 1ph 50/60Hz | ||
| K7/16BP3-G115MT | Quote Required | TBD | 300.0 | OIL-X AOPX015C and AAPX015C (Included) | 85 | BSPP | < 75 | Filtration | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | IP65 Indoor Use Only | 1358.0 | ISO8573-1:2010 Class 2.2.1 | 4 to 16 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 748.0 | -40 | Breathing Air Purifier | 5 to 50 | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 50.0 °C Maximum | Dew Point Sensor | ½ inch | 116 m³/h @ 13 barg (68 cfm @ 189 psig) | 115V 1ph 50/60Hz | ||
| K7/16BP3-G230M | Quote Required | TBD | 11.8 inch | OIL-X AOPX015C and AAPX015C (Included) | 187.4 lb | BSPP | < 75 dBA | Filtration | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | IP65 Indoor Use Only | 1358.0 mm | ISO8573-1:2010 Class 2.2.1 | 58 to 232 psig | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 748.0 mm | -40 °C | Breathing Air Purifier | 5 to 50 °C | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 122.0 °F Maximum | None | ½ inch | 116 m³/h @ 13 barg (68 cfm @ 189 psig) | 230V 1ph 50/60Hz | ||
| K7/16BP3-G230MT | Quote Required | TBD | 11.8 inch | OIL-X AOPX015C and AAPX015C (Included) | 187.4 lb | BSPP | < 75 dBA | Filtration | OIL-X AOPX015C (Included)<br/>OIL-X AAPX015C (Option) | IP65 Indoor Use Only | 1358.0 mm | ISO8573-1:2010 Class 2.2.1 | 58 to 232 psig | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 29.4 inch | -40.0 °F | Breathing Air Purifier | 5 to 50 °C | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 122.0 °F Maximum | Dew Point Sensor | ½ inch | 116 m³/h @ 13 barg (68 cfm @ 189 psig) | 230V 1ph 50/60Hz | ||
| K8/16BP3-G115M | Quote Required | TBD | 300.0 | OIL-X AOPX020D and AAPX020D (Included) | 97 | BSPP | < 75 | Filtration | OIL-X AOPX020D (Included)<br/>OIL-X AAPX020D (Option) | IP65 Indoor Use Only | 61 | ISO8573-1:2010 Class 2.2.1 | 4 to 16 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 748.0 | -40 | Breathing Air Purifier | 5 to 50 | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 50.0 °C Maximum | None | ½ inch | 139 m³/h @ 13 barg (82 cfm @ 189 psig) | 115V 1ph 50/60Hz | ||
| K8/16BP3-G115MT | Quote Required | TBD | 300.0 | OIL-X AOPX020D and AAPX020D (Included) | 97 | BSPP | < 75 | Filtration | OIL-X AOPX020D (Included)<br/>OIL-X AAPX020D (Option) | IP65 Indoor Use Only | 1558.0 | ISO8573-1:2010 Class 2.2.1 | 4 to 16 | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 748.0 | -40 | Breathing Air Purifier | 5 to 50 | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 50.0 °C Maximum | Dew Point Sensor | ½ inch | 139 m³/h @ 13 barg (82 cfm @ 189 psig) | 115V 1ph 50/60Hz | ||
| K8/16BP3-G230M | Quote Required | TBD | 11.8 inch | OIL-X AOPX020D and AAPX020D (Included) | 97 kg | BSPP | < 75 dBA | Filtration | OIL-X AOPX020D (Included)<br/>OIL-X AAPX020D (Option) | IP65 Indoor Use Only | 1558.0 mm | ISO8573-1:2010 Class 2.2.1 | 4 to 16 barg | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 29.4 inch | -40 °F | Breathing Air Purifier | 5 to 50 °C | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 122.0 °F Maximum | None | ½ inch | 139 m³/h @ 13 barg (82 cfm @ 189 psig) | 230V 1ph 50/60Hz | ||
| K8/16BP3-G230MT | Quote Required | TBD | 300.0 mm | OIL-X AOPX020D and AAPX020D (Included) | 213.9 lb | BSPP | < 75 dBA | Filtration | OIL-X AOPX020D (Included)<br/>OIL-X AAPX020D (Option) | IP65 Indoor Use Only | 1558.0 mm | ISO8573-1:2010 Class 2.2.1 | 4 to 16 barg | Agriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp & | Parker | PED 2014/68/EU Fluid Group II | Gas Separation and Filtration Division EMEA | 29.4 inch | -40 °F | Breathing Air Purifier | 41 to 122 °F | BSP-MT 1-8 | • Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• Demolition | 50.0 °C Maximum | Dew Point Sensor | ½ inch | 139 m³/h @ 13 barg (82 cfm @ 189 psig) | 230V 1ph 50/60Hz |