• Availability & Price
  • Search SKU
Filter by attributes
  • Flow Rate
  • Port Size
More Filters...
Filter by manufacturer
Manufacturers

BAM Breathing Air System

Picture for category BAM Breathing Air System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Hazardous vapours, gases and fumes can be released at various stages within manufacturing applications. Whether the risk is from noxious fumes, particulate or contamination from a compressed air system, effective respiratory protection for the user is essential.

In compressed air fed systems, ambient air is drawn into the compressor, therefore any contaminants present in the ambient air, plus those introduced by the compressor itself, will be present unless removed by a purification system.

The Parker BAM breathing system consists of seven purification stages mounted on a portable skid for high-capacity multiple personnel breathing air applications.

At the inlet, a water separator removes bulk water, followed immediately by two OIL-X coalescing filters to reduce oil and water content. The fourth stage of purification is an adsorption dryer that reduces the water vapour content of the compressed air (to -40°C pdp) and CO2 to below the legal permissible limits. Downstream of the adsorption dryer an activated carbon filter then reduces oil vapour and odours, then a catalyst filter reduces carbon monoxide to carbon dioxide, again, to below the legal limits. A final dust filter captures any particulates carried over from the adsorption materials.

Features
• 7 Purification stages

• CO monitor fitted as standard

• CO and CO2 reduction to below legal permissible limits

• Air quality 3rd party independently certified, better than the European Pharmacopoeia standard

• Energy management system fitted as standard

• Modular, space saving design

• Use with any compressed air supply

Please note this product is currently only available in Europe.

Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionIndustryApplicationSpecifications MetNoise LevelWeightDepthWidthHeightProduct TypeProduct SeriesConnection TypeOperating PressureAmbient TemperatureOperating TemperatureElectrical RequirementsIngress Protection RatingISO GradePressure Dew PointCompatible PrefilterCompatible After FilterPort SizeFlow Rate
BAM10
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA600 kg1655.0 mm49.6 inch1797.0 mmBreathing Air PurifierBAMBSPP or NPT4 to 13 barg55.0 °C Maximum41 to 95 °FStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40 °FOIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2 inch408 m³/h @ 7 barg (240 cfm @ 102 psig)
BAM20
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA1543 lb65.2 inch1260.0 mm1797.0 mmBreathing Air PurifierBAMBSPP or NPT58 to 190 psig131.0 °F Maximum41 to 95 °FStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40 °COIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2 inch612 m³/h @ 7 barg (360 cfm @ 102 psig)
BAM30
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA800 kg65.2 inch1260.0 mm80.4 inchBreathing Air PurifierBAMBSPP or NPT4 to 13 barg131.0 °F Maximum5 to 35 °CStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40.0 °FOIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2 inch795 m³/h @ 7 barg (450cfm @ 102 psig)
BAM40
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA900 kg1655.0 mm49.6 inch2042.0 mmBreathing Air PurifierBAMBSPP or NPT58 to 190 psig131.0 °F Maximum41 to 95 °FStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40.0 °FOIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2 inch1020 m³/h @ 7 barg (600 cfm @ 102 psig)
BAM50
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA1100 kg1950.0 mm1260.0 mm80.4 inchBreathing Air PurifierBAMBSPP or NPT4 to 13 barg55.0 °C Maximum5 to 35 °CStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40 °COIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2½ inch1275 m³/h @ 7 barg (750 cfm @ 102 psig)
BAM70
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II< 75 dBA3086 lb1950.0 mm49.6 inch80.4 inchBreathing Air PurifierBAMBSPP or NPT4 to 13 barg131.0 °F Maximum5 to 35 °CStandard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use OnlyISO8573-1:2010 Class 1.2.1-40 °FOIL-X Grades AO and AA Coalescing (Included)OIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)2½ inch1785 m³/h @ 7 barg (1050 cfm @ 102 psig)