- Availability & Price
- Search SKU
Filter by attributes
- Configuration
- Flow Direction
- Flow Rate
- Seal Material
- Sealed Pilot Included
- Switching Pressure
Filter by manufacturer
3 Way Pilot Operated Directional Control Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s series of 3-way, pilot-operated directional control valves feature a strong design for maximum durability and performance that can operate with hydraulic system flows as high as 90 lpm and pressures up to 420 bar. The high pressure and flow capabilities of Parker’s selection make these valves suitable for high flow switching, diverting, bypassing, or unloading applications within a broad range of markets, such as the agriculture, construction, material handling and industrial markets.
Normally-open or normally-closed options are available depending on application needs, and can even be configured with a vent to atmosphere option for the spring chamber. Parker’s spring chamber vent to atmosphere design is especially beneficial when high pilot pressures are not readily available, which will help ensure proper valve and system functionality.
Markets:
• Aerial
• Agricultural Machinery
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High flow capacity
• Multiple switching pressure options
• Sealed pilot option available
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Bypass flow paths
• Diverter for hydrostatic transmission cooling or filtration
• Enabling/disabling functions
• Enabling/disabling hydraulic subsystems
• Regen functions
Additional Technical Insight:
Parker’s 3-way, pilot-operated series of directional control valves are available both normally-open and normally-closed, with flow and pressure ranging up to 90 lpm (24 gpm) and 420 bar (6,000 psi) respectively. Two versions of both the normally-open and normally-closed are available at varying flow and pressure ratings depending on the application needs. This series of valve acts as flow diverters and redirects the hydraulic fluid’s flow path from the valve’s neutral position to its shifted position by providing external pilot pressure to port 1 (nose) of the valve. The neutral or un-shifted position of the normally-open valves allow bidirectional flow from port 3 to port 2, with the 4th port blocked. When pilot pressure is provided to port 1, the spool shifts and then redirects the flow to between the 3rd and 4th port, blocking port 2. There is a selection of valves in this family that vent to atmosphere, allowing pressure equalization in the spring chamber. The remaining valves in this family vent the spring chamber internally through the 4th port, and as a result it is advised that port 4 is located on the lower pressure side of the valve and/or the tank line. Also, any additional pressure seen at port 4 is additive to the spring setting, which may impact the pilot pressure necessary to shift the valve. Pilot pressures of 2.8 bar (40 psi), 5.5 bar (80 psi), and 11 bar (160 psi) are available as standard options on the lower flow valves, and pilot pressures of 5 bar (73 psi) and 10 bar (145 psi) are available for the higher flow valves.
For all valves where the spring chamber is vented internally, the 4th port should be connected to the lower pressure flow path and/or ideally the tank line.
Read More...Normally-open or normally-closed options are available depending on application needs, and can even be configured with a vent to atmosphere option for the spring chamber. Parker’s spring chamber vent to atmosphere design is especially beneficial when high pilot pressures are not readily available, which will help ensure proper valve and system functionality.
Markets:
• Aerial
• Agricultural Machinery
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High flow capacity
• Multiple switching pressure options
• Sealed pilot option available
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Bypass flow paths
• Diverter for hydrostatic transmission cooling or filtration
• Enabling/disabling functions
• Enabling/disabling hydraulic subsystems
• Regen functions
Additional Technical Insight:
Parker’s 3-way, pilot-operated series of directional control valves are available both normally-open and normally-closed, with flow and pressure ranging up to 90 lpm (24 gpm) and 420 bar (6,000 psi) respectively. Two versions of both the normally-open and normally-closed are available at varying flow and pressure ratings depending on the application needs. This series of valve acts as flow diverters and redirects the hydraulic fluid’s flow path from the valve’s neutral position to its shifted position by providing external pilot pressure to port 1 (nose) of the valve. The neutral or un-shifted position of the normally-open valves allow bidirectional flow from port 3 to port 2, with the 4th port blocked. When pilot pressure is provided to port 1, the spool shifts and then redirects the flow to between the 3rd and 4th port, blocking port 2. There is a selection of valves in this family that vent to atmosphere, allowing pressure equalization in the spring chamber. The remaining valves in this family vent the spring chamber internally through the 4th port, and as a result it is advised that port 4 is located on the lower pressure side of the valve and/or the tank line. Also, any additional pressure seen at port 4 is additive to the spring setting, which may impact the pilot pressure necessary to shift the valve. Pilot pressures of 2.8 bar (40 psi), 5.5 bar (80 psi), and 11 bar (160 psi) are available as standard options on the lower flow valves, and pilot pressures of 5 bar (73 psi) and 10 bar (145 psi) are available for the higher flow valves.
For all valves where the spring chamber is vented internally, the 4th port should be connected to the lower pressure flow path and/or ideally the tank line.
| Action | Part No. | Availability | Partner Available | Price | Maximum Flow Rate | Filter Efficiency Rating | Standard Flow Rate Setting | Switching Pressure | Valve Material | Flow Rate | Maximum Inlet Pressure Rating | Flow Direction | Division | Sealed Pilot Included | Minimum Operating Temperature | Operating Temperature | Maximum Operating Temperature | Maximum Operating Pressure | Leak Rate | Weight | Cavity Size | Installation Torque | Configuration | Pilot Location | Body Material | Seal Material | Function | Drain Option | Operation Type | Maximum Kinematic Viscosity | For Fluid Type | Actuation Type | Flow Direction | Flow Rate | Sealed Pilot Included | Configuration | Seal Material | Switching Pressure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N04G4-9.0V | Quote Required | TBD | 24 Gal/min | ISO 4406 18/16/13, SAE Class 4 | 13 Gal/min | 131 psi | All parts steel. All operating parts hardened steel | 85 L/min | 420 bar | 2-3 Neutral, 3-4 Piloted | Mobile Hydraulic Systems Division Europe | No | -15 °F | -15 to +400 °F | +204 °C | 420 bar | 55 @ 1450 PSI (100 BAR) cm3/min | 0.48 lb | C10-4 | 37 lb-ft | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 2-3 Neutral, 3-4 Piloted | 22.5 GAL/MIN, 85 LPM | No | Open Transition | Fluorocarbon | 131 PSI, 9 BAR | ||
| N04G4-9.0VS | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 131 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 2-3 Neutral, 3-4 Piloted | Mobile Hydraulic Systems Division Europe | Yes | -15 | -15 to +400 | +400 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 2-3 Neutral, 3-4 Piloted | 22.5 GAL/MIN, 85 LPM | Yes | Open Transition | Fluorocarbon | 131 PSI, 9 BAR | ||
| N04H4-15.0N | Quote Required | TBD | 24 Gal/min | ISO 4406 18/16/13, SAE Class 4 | 13 Gal/min | 218 psi | All parts steel. All operating parts hardened steel | 22.5 Gal/min | 6000 psi | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | No | -34 °C | -30 to +250 °F | +250 °F | 420 bar | 55 @ 1450 PSI (100 BAR) cm3/min | 0.48 lb | C10-4 | 37 lb-ft | Open Transition | External | n/a | Nitrile | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | No | Open Transition | Nitrile | 218 PSI, 15 BAR | ||
| N04H4-15.0NS | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 218 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | Yes | -30 | -30 to +250 | +250 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Nitrile | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | Yes | Open Transition | Nitrile | 218 PSI, 15 BAR | ||
| N04H4-15.0V | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 218 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | No | -15 | -15 to +400 | +400 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | No | Open Transition | Fluorocarbon | 218 PSI, 15 BAR | ||
| N04H4-15.0VS | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 218 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | Yes | -15 | -15 to +400 | +400 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | Yes | Open Transition | Fluorocarbon | 218 PSI, 15 BAR | ||
| N04H4-9.0N | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 131 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | No | -30 | -30 to +250 | +250 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Nitrile | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | No | Open Transition | Nitrile | 131 PSI, 9 BAR | ||
| N04H4-9.0NS | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 131 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | Yes | -30 | -30 to +250 | +250 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Nitrile | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | Yes | Open Transition | Nitrile | 131 PSI, 9 BAR | ||
| N04H4-9.0V | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 131 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | No | -15 | -15 to +400 | +400 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | No | Open Transition | Fluorocarbon | 131 PSI, 9 BAR | ||
| N04H4-9.0VS | Quote Required | TBD | 24 | ISO 4406 18/16/13, SAE Class 4 | 13 | 131 | All parts steel. All operating parts hardened steel | 22.5 | 6000 | 3-4 Neutral, 2-3 Piloted | Mobile Hydraulic Systems Division Europe | Yes | -15 | -15 to +400 | +400 | 6000 | 55 @ 1450 PSI (100 BAR) | 0.48 | C10-4 | 37 | Open Transition | External | n/a | Fluorocarbon | Directional Control | Vent to Atmosphere | Pilot Operated | 45-2000 SSU (6 to 420 cSt) | Mineral-based or synthetic hydraulic fluids | Pilot to shift | 3-4 Neutral, 2-3 Piloted | 22.5 GAL/MIN, 85 LPM | Yes | Open Transition | Fluorocarbon | 131 PSI, 9 BAR |