• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Rate
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

3 Way Flow Control Proportional Valves

Picture for category 3 Way Flow Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 3-way flow control proportional valves provide repeatable and precise controls to circuits requiring proportional flow control through 3 lines in a normally-closed configuration. These valves are capable of handling flows up to 75 lpm (20 gpm) and pressures as high as 210 bar (3000 psi). These valves can achieve pseudo pressure due to the pressure drop across the spool orifices, but an external compensator can also be used if finer control is required, making these valves ideal for variable flow sharing applications that need exact control with to ability to close off one leg of the circuit completely. Parker’s 3-way flow control proportional valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• Non-magnetic spool and housing assembly
• Precise factory setting

Applications:
• Applications requiring precise controls
• Variable flow applications
• Priority flow sharing

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Regulated Flow RateConfigurationCurrentLeak RateInstallation TorqueFunctionFilter Efficiency RatingCavity SizeOperating TemperatureHysteresisCoil Nut Tightening TorqueBody MaterialOperation TypeConnection TypeMaximum Operating TemperatureOverride FunctionalityValve MaterialFlow RateFrequencyMinimum Pressure DifferentialDivisionMinimum Operating TemperatureSeal MaterialWeightMaximum Kinematic ViscosityVariation of Opening PointActuation TypeMaximum Flow RateFlow DirectionConnection SizePower ConsumptionMaximum Inlet Pressure RatingFor Fluid TypeFlow Rate AccuracyMaximum Operating PressureCoil TypeFlow RateSeal MaterialActuation TypeConfigurationDivision
DFA125C31SN
Quote Required
TBD
56.8Normally Closed, Pressure Compensated2.33 @ 12 VDC, 1.17 @ 24 VDC568 @ 3000 PSI (210 BAR)55Proportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 4C12-4L-30 to +250< 15%3n/aSolenoid operated, Manually opertatedn/a+250Infinite ControlAll parts steel. All operating parts hardened steel20100-400200Hydraulic Systems Division-30Nitrile145-2000 SSU (6 to 420 cSt)N/AElectrical, Manual20Inlet port 3, Bypass port 2, Regulated port 4n/a283000Mineral-based or synthetic hydraulic fluidsN/A30005/8" Super Coil High Watt (CAP)20 GAL/MIN, 75 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
DFA125C31SV
Quote Required
TBD
56.8Normally Closed, Pressure Compensated2.33 @ 12 VDC, 1.17 @ 24 VDC568 @ 3000 PSI (210 BAR)55Proportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 4C12-4L-15 to +400< 15%3n/aSolenoid operated, Manually opertatedn/a+400Infinite ControlAll parts steel. All operating parts hardened steel20100-400200Hydraulic Systems Division-15Fluorocarbon145-2000 SSU (6 to 420 cSt)N/AElectrical, Manual20Inlet port 3, Bypass port 2, Regulated port 4n/a283000Mineral-based or synthetic hydraulic fluidsN/A30005/8" Super Coil High Watt (CAP)20 GAL/MIN, 75 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP04C3100N
Quote Required
TBD
7, 8 Gal/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min30 NmProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-30 to +250 °F7%3 lb-ftn/aSolenoid Operatedn/a+121 °Cn/aAll parts steel. All operating parts hardened steel60 L/min100-400 Hz13.8, 20.7 barHydraulic Systems Division-34 °CNitrile0.31 lb45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical16 Gal/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W210 barMineral-based or synthetic hydraulic fluids+/- 50% of Input Signal3000 psi5/8" Super Coil16 GAL/MIN, 60 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP04C3100NL
Quote Required
TBD
26, 30 L/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min22 lb-ftProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-30 to +250 °F7%4.1 Nmn/aSolenoid Operatedn/a+121 °Cn/aAll parts steel. All operating parts hardened steel60 L/min100-400 Hz13.8, 20.7 barHydraulic Systems Division-34 °CNitrile0.14 kg45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical60 L/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W210 barMineral-based or synthetic hydraulic fluids+/- 20% of Input Signal210 bar5/8" Super Coil16 GAL/MIN, 60 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP04C3100V
Quote Required
TBD
26, 30 L/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min30 NmProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-26 to +204 °C7%3 lb-ftn/aSolenoid Operatedn/a+400 °Fn/aAll parts steel. All operating parts hardened steel16 Gal/min100-400 Hz13.8, 20.7 barHydraulic Systems Division-15 °FFluorocarbon0.31 lb45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical60 L/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W3000 psiMineral-based or synthetic hydraulic fluids+/- 50% of Input Signal210 bar5/8" Super Coil16 GAL/MIN, 60 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP04C3100VL
Quote Required
TBD
26, 30 L/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min22 lb-ftProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-15 to +400 °F7%3 lb-ftn/aSolenoid Operatedn/a+204 °Cn/aAll parts steel. All operating parts hardened steel16 Gal/min100-400 Hz13.8, 20.7 barHydraulic Systems Division-15 °FFluorocarbon0.31 lb45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical16 Gal/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W210 barMineral-based or synthetic hydraulic fluids+/- 20% of Input Signal3000 psi5/8" Super Coil16 GAL/MIN, 60 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP04C3150N
Quote Required
TBD
26, 30 L/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min22 lb-ftProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-34 to +121 °C7%4.1 Nmn/aSolenoid operated, Manually opertatedn/a+250 °FInfinite ControlAll parts steel. All operating parts hardened steel16 Gal/min100-400 Hz200, 300 psiHydraulic Systems Division-30 °FNitrile0.14 kg45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical, Manual16 Gal/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W3000 psiMineral-based or synthetic hydraulic fluids+/- 50% of Input Signal3000 psi5/8" Super Coil16 GAL/MIN, 60 L/MINNitrileElectrical, ManualNormally Closed, Pressure CompensatedHydraulic Cartridge Systems Division
JP04C3150NL
Quote Required
TBD
26, 30 L/minNormally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC A780 @ 3000 PSI (210 BAR) cm3/min22 lb-ftProportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-34 to +121 °C7%4.1 Nmn/aSolenoid operated, Manually opertatedn/a+250 °FInfinite ControlAll parts steel. All operating parts hardened steel60 L/min100-400 Hz200, 300 psiHydraulic Systems Division-34 °CNitrile0.14 kg45-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical, Manual60 L/minInlet port 3, Bypass port 2, Regulated port 4n/a18, 28 W3000 psiMineral-based or synthetic hydraulic fluids+/- 20% of Input Signal210 bar5/8" Super Coil16 GAL/MIN, 60 L/MINNitrileElectrical, ManualNormally Closed, Pressure Compensated
JP04C3150V
Quote Required
TBD
26, 30Normally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC780 @ 3000 PSI (210 BAR)22Proportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-15 to +4007%3n/aSolenoid operated, Manually opertatedn/a+400Infinite ControlAll parts steel. All operating parts hardened steel16100-400200, 300Hydraulic Systems Division-15Fluorocarbon0.3145-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical, Manual16Inlet port 3, Bypass port 2, Regulated port 4n/a18, 283000Mineral-based or synthetic hydraulic fluids+/- 50% of Input Signal30005/8" Super Coil16 GAL/MIN, 60 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated
JP04C3150VL
Quote Required
TBD
26, 30Normally Closed, Pressure Compensated1.50 @ 12 VDC, 2.33 @ 12 VDC, 0.75 @ 24 VDC, 1.17 @ 24 VDC780 @ 3000 PSI (210 BAR)22Proportional Flow Control/RegulatorISO 4406 18/16/13, SAE Class 44C-15 to +4007%3n/aSolenoid operated, Manually opertatedn/a+400Infinite ControlAll parts steel. All operating parts hardened steel16100-400200, 300Hydraulic Systems Division-15Fluorocarbon0.3145-2000 SSU (6 to 420 cSt)17% Nominal Amperage, 21% Nominal AmperageElectrical, Manual16Inlet port 3, Bypass port 2, Regulated port 4n/a18, 283000Mineral-based or synthetic hydraulic fluids+/- 20% of Input Signal30005/8" Super Coil16 GAL/MIN, 60 L/MINFluorocarbonElectrical, ManualNormally Closed, Pressure Compensated