- Availability & Price
- Search SKU
Filter by attributes
- Flow Rate (gpm)
- Maximum Operating Pressure (psi)
- Resistance (Ohms)
- Seal Material
- Wiring
Filter by manufacturer
Recently viewed products
Two-Stage Torque Motor Servovalve – DY Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s DY series the unique rigid pin feedback design avoids ball glitch problems, which can occur in other types of servovalves. The valves are rated for 210 Bar (3000 PSI) standard, or can be built for 350 Bar (5000 PSI) service and the pressure ratings are the same for both the tool steel construction or the optional stainless steel spool and body.
Markets:
• Defense
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Power Generation
Features/Benefits:
• No ball glitch
• Lapped spool & body
• Survives high tank port pressures
• Tool steel, or stainless steel, spool & body
• Versatile 21.59 mm (0.850 in.) port circle, can mount to standard 19.81 mm (0.780 in.) and 23.62 mm (0.930 in.) port circle patterns.
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Defense
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Power Generation
Features/Benefits:
• No ball glitch
• Lapped spool & body
• Survives high tank port pressures
• Tool steel, or stainless steel, spool & body
• Versatile 21.59 mm (0.850 in.) port circle, can mount to standard 19.81 mm (0.780 in.) and 23.62 mm (0.930 in.) port circle patterns.
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Valve Type | Division | Maximum Operating Pressure | Maximum Operating Temperature | Maximum Flow Rate | Minimum Operating Temperature | Actuation Type | Additional Options | Body Material | Seal Material | Weight | Seal Material | Maximum Operating Pressure (psi) | Resistance (Ohms) | Flow Rate (gpm) | Wiring |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DY3HARCNE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 0.56 | Nitrile | 1500 | 750 Ohms; 30 mA (Parallel); 15 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY3HARCVE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 0.56 | Fluorocarbon | 1500 | 750 Ohms; 30 mA (Parallel); 15 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY3HATCNE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 0.56 | Nitrile | 1500 | 1000 Ohms; 10 mA (Parallel); 5 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY3HATCVE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 0.56 | Fluorocarbon | 1500 | 1000 Ohms; 10 mA (Parallel); 5 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY3HAVCNE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 0.56 | Nitrile | 1500 | 1200 Ohms: 40 mA (Parallel); 20 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY3HAVCVE3 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 1500.0 | +180 | 3 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 0.56 | Fluorocarbon | 1500 | 1200 Ohms: 40 mA (Parallel); 20 mA (Series) | 3 | Port C1; (+) signal A, C | ||
| DY45ADCNA40 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 40 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 40 | Port C1; (+) signal A, C | ||
| DY45ADCNA50 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 50 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 50 | Port C1; (+) signal A, C | ||
| DY45ADCNA60 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 60 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 60 | Port C1; (+) signal A, C | ||
| DY45ADCNB40 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 40 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 40 | Port C1; (+) signal A, C | ||
| DY45ADCNB50 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 50 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 50 | Port C1; (+) signal A, C | ||
| DY45ADCNB60 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 60 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 60 | Port C1; (+) signal A, C | ||
| DY45ADCVA40 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 40 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 40 | Port C1; (+) signal A, C | ||
| DY45ADCVA50 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 50 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 50 | Port C1; (+) signal A, C | ||
| DY45ADCVA60 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 60 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 60 | Port C1; (+) signal A, C | ||
| DY45ADCVB40 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 40 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 40 | Port C1; (+) signal A, C | ||
| DY45ADCVB50 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 50 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 50 | Port C1; (+) signal A, C | ||
| DY45ADCVB60 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 5000.0 | +180 | 60 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Fluorocarbon | 16 | Fluorocarbon | 5000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 60 | Port C1; (+) signal A, C | ||
| DY45ADDNA40 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 40 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 40 | Port C1; (+) signal B, D | ||
| DY45ADDNA50 | Quote Required | TBD | Servovalve | Hydraulic Valve Systems Division | 3000.0 | +180 | 50 | +30 | Hydraulic Pressure | Consult catalog for additional features | Steel | Nitrile | 16 | Nitrile | 3000 | 200 Ohms; 50 mA (Parallel); 25 mA (Series) | 50 | Port C1; (+) signal B, D |