Transair® Fittings for Stainless Steel Pipe
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Transair Fittings for Stainless Steel Pipe are quick and easy to install. All fittings are designed to securely fit around Transair stainless steel pipe, increasing system efficiency and preventing leaks. Transair fittings for stainless steel pipe are available in a variety of styles for easy assembly and layout design for compressed air, vacuum, industrial/inert gas, process water, or chemical transfer system. Fittings are available with either FKM or EPDM for robust chemical compatibility.
The “full bore” design of Transair fittings pair with the low coefficient of friction in the stainless steel pipe ensures optimal flow throughout the system. All components are 100% recyclable, silicone free, and manufactured from materials with no propagation of flame. Parker Hannifin warrants all Transair components to be free of defects in material and workmanship for 10 years from the date of installation.
Transair 3/4" (22mm) and 1” (28mm) fittings use push-to-connect technology. To install, mark the insertion depth on the pipe and insert the pipe into the fitting until the edge of the connector meets the marked line on the pipe.
Transair 1-1/2” (42mm) and 2” (60mm) fittings use clamp ring technology. To install, place the clamp ring over the lugs at the end of the pipe and slide the fitting nut in place. Next, hand tighten the nut onto the body. Lastly, use a pair of spanner wrenches to tighten the fitting one-half (1/2) turn. All 1-1/2” and 2” stainless steel pipe comes from the factory pre-lugged, but if field cutting is required, the lugs need to be made using a Transair lugging tool and die.
Transair 3” (76mm) and 4” (101mm) fittings use clamshell technology. To install, place the remove cartridge over the end of the pipe until it meets the lugs. Next, place the clamshell union over the cartridge and tighten the fitting using a cross bolt pattern. All 3” and 4” stainless steel pipe comes from the factory pre-lugged, but if field cutting is required, the lugs need to be made using a Transair lugging tool and die.
For full installation instructions, download our stainless steel catalog.
Markets:
• Automotive Assembly
• Food & Beverage
• Packaging
• Industrial Plants
• Aerospace
Features/Benefits:
• Quick connection technology
• Modular & reusable
• Corrosion resistant
• Optimum flow rate
• 100% Recyclable
• Faster installation
• Lower installation costs
• Immediate Pressurization
• 10-year warranty
Applications:
• Compressed Air
• Vacuum
• Industrial/Inert Gases (i.e. Argon, Nitrogen, Carbon Dioxide)
• Process Water
• Chemical Transfer
Maximum Working Pressure:
• 145psi (10bar) when the system is operated from +14 to +140F (-20 to +60C)
• 100psi (7bar) when the system is operated from +14 to +194F (-20 to +90C)
Maximum Operating Temperature:
• +194F (+90C) when the system is operated with FKM seals and at 100psi (7bar) or lower
| Action | Part No. | Availability | Partner Available | Price | Product Type | Division | Minimum Operating Temperature | Body Material | Application | Vacuum Pressure Rating | Maximum Operating Pressure | Product Style | Connection 1 Size | Assembly Time | Quantity per Box | Maximum Operating Temperature | Weight | Shape | Configuration | Connection 1 Type | Seal Material | Pipe O.D. (mm) | Pipe O.D. (inch) | Connection Thread Size (inch) | Pipe O.D. 2 (mm) | Pipe O.D. 2 (inch) | Shape | Division | Connection 2 Size | Pipe Outside Diameter | Connection 2 Type | Brand | Seal Material | Connection 3 Type | Connection 3 Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EF25 00 04 02 | Quote Required | TBD | Compressed Air Piping | Fluid System Connectors Division | -4 °F | Stainless Steel 316 | Vacuum | 1 mbar | 10 bar | Stud Fitting | G 1/2 inch | 0 Hours | 50 | 194 °F | 0,176 lb | End Cp | Port to End | Male BSPP | FKM | N/A | N/A | 1/2 | N/A | N/A | 316L Stainless Steel Plug | ||||||||||
| RF02 N7 00 | Quote Required | TBD | Compressed Air Piping | Fluid System Connectors Division | -20 °C | Inert Gases | 0.03 inch-Hg | 145 psi | Elbow | 3/4 inch | 0.04 Hours | 1.0 | 90 °C | 0.27 kg | Elbow 90° | Pipe to Pipe | Pipe | N/A | 22 | 3/4 | n/a | N/A | N/A | 316L Stainless 90° Bent Pipe Elbow | Low Pressure Connectors Europe Division | 22 mm | 22 mm | Pipe | Transair | ||||||
| RF02 N7 02 | Quote Required | TBD | Elbow | Fluid System Connectors Division | -20 °C | Stainless Steel 316 | Process Water | 0.03 inch-Hg | 145 psi | Elbow | 3/4 inch | 0.04 Hours | 1.0 | 90 °C | 0.66 lb | Elbow 90° | Pipe to Pipe | Pipe | FKM | 22 | 3/4 | n/a | N/A | N/A | 316L Stainless 90° Elbow | Low Pressure Connectors Europe Division | 22 mm | 3/4 inch | Pipe | Transair | FKM | ||||
| RF04 06 00 | Quote Required | TBD | Compressed Air Piping | Fluid System Connectors Division | -4 °F | Process Water | 0.03 inch-Hg | 10 bar | Stud Fitting | 3/4 inch | 0.17 Hours | 1.0 | 194 °F | 0.67 lb | Tee | Port to Port | Female BSPT | N/A | N/A | N/A | 3/4 | N/A | N/A | 316L Stainless BSP Tee | Low Pressure Connectors Europe Division | 3/4 inch | Female BSPT | Transair | Female BSPT | 3/4 inch | |||||
| RF04 06N00 | Quote Required | TBD | Tee | Fluid System Connectors Division | -4 °F | Compressed Air | 0.03 inch-Hg | 10 bar | Stud Fitting | 3/4 inch | 0.17 Hours | 1.0 | 194 °F | 0.67 lb | Tee | Port to Port | Female NPT | N/A | N/A | N/A | 3/4 | N/A | N/A | 316L Stainless NPT Tee | Fluid System Connectors Division | 3/4 inch | Female NPT | Transair | Female NPT | 3/4 inch | |||||
| RF05 N7N06 | Quote Required | TBD | Compressed Air Piping | Fluid System Connectors Division | -4 °F | Compressed Air | 1 mbar | 145 psi | Stud Fitting | 3/4 inch | 0.17 Hours | 1.0 | 194 °F | 0.12 kg | Adapter | Pipe to Port | Pipe | FKM | 22 | 3/4 | 3/4 | N/A | N/A | 316L Stainless Transair Female to Male NPT Adapter | Low Pressure Connectors Europe Division | 3/4 inch | 22 mm | Male NPT | Transair | ||||||
| RF06 N7 02 | Quote Required | TBD | Union Fitting | Fluid System Connectors Division | -4 °F | Compressed Air | 0.03 inch-Hg | 10 bar | Union Fitting | 22 mm | 0.04 Hours | 5.0 | 90 °C | 0.23 kg | Straight | Pipe to Pipe | Pipe | FKM | 22 | 3/4 | n/a | N/A | N/A | 316L Stainless Union | Fluid System Connectors Division | 22 mm | 3/4 inch | Pipe | Transair | FKM | |||||
| RF08 N7 06 02 | Quote Required | TBD | Compressed Air Piping | Fluid System Connectors Division | -4 °F | Process Water | 0.03 inch-Hg | 10 bar | Stud Fitting | 22 mm | 0.17 Hours | 1.0 | 194 °F | 0.12 kg | Straight | Pipe to Port | Pipe | FKM | 22 | 3/4 | 3/4 | N/A | N/A | 316L Stainless Male BSP Adapter | Low Pressure Connectors Europe Division | 3/4 inch | 22 mm | Male BSPT | Transair | ||||||
| RP02 M4 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Industrial Gas | 1 | 145 | 194 | EPDM | 42 | 1-1/2 | n/a | N/A | N/A | 90° Elbow | ||||||||||||||||||||
| RP02 M4 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 42 | 1-1/2 | n/a | N/A | N/A | 90° Elbow | ||||||||||||||||||||
| RP02 M6 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | EPDM | 60 | 2-1/2 | n/a | N/A | N/A | 90° Elbow | ||||||||||||||||||||
| RP02 M6 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 60 | 2-1/2 | n/a | N/A | N/A | 90° Elbow | ||||||||||||||||||||
| RP04 M4 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | EPDM | 42 | 1-1/2 | n/a | N/A | N/A | Equal Tee | ||||||||||||||||||||
| RP04 M4 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 42 | 1-1/2 | n/a | N/A | N/A | Equal Tee | ||||||||||||||||||||
| RP04 M6 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | EPDM | 60 | 2-1/2 | n/a | N/A | N/A | Equal Tee | ||||||||||||||||||||
| RP04 M6 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 60 | 2-1/2 | n/a | N/A | N/A | Equal Tee | ||||||||||||||||||||
| RP06 M4 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | EPDM | 42 | 1-1/2 | n/a | N/A | N/A | Union | ||||||||||||||||||||
| RP06 M4 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 42 | 1-1/2 | n/a | N/A | N/A | Union | ||||||||||||||||||||
| RP06 M6 01 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | EPDM | 60 | 2-1/2 | n/a | N/A | N/A | Union | ||||||||||||||||||||
| RP06 M6 02 | Quote Required | TBD | Fluid System Connectors Division | -4 | Vacuum | 1 | 145 | 194 | FKM | 60 | 2-1/2 | n/a | N/A | N/A | Union |