- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve (bar)
- Bypass Valve Pressure Rating
- Connection Type
- Filter Element
- Filter Element Type
- Flow Capacity (l/min)
- Flow Rate
- Indicator Type
- Micron Rating
- Options
Filter by manufacturer
Tanktop Mounted Return Line Filter - TTF Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak back into the system during element change.
TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
Read More...TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
| Action | Part No. | Availability | Partner Available | Price | Technology | Product Style | Mounting Type | Operating Pressure | Division | Product Series | Indicator Pressure Setting | Division | Application | Industry | Brand | Product Type | Filter Element Type | Bypass Valve Pressure Rating | Operating Temperature | Flow Rate | Connection Type | Filter Element | Indicator Type | Micron Rating | Seal Material | Bypass Valve Pressure Rating | Filter Element Type | Options | Flow Capacity (l/min) | Port Connection Type | Bypass Valve (bar) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TTF1005QBG1EG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05Q Microglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1½ | 05Q Microglass | Visual M10x1 | 5 µm | Nitrile | 1.5 bar | 05Q Microglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1005QBP2HG245 | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05Q Microglass | 2 | -40 to 100 | 0 to 400 l/min | G1½ | 05Q Microglass | No indicator, port plugged L+R | 5 µm | Nitrile | 2.0 bar | 05Q Microglass | No Diffuser, No Magnets | 500 * | G1½ * | 2 | ||
| TTF1005QBS1EG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05Q Microglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1½ | 05Q Microglass | Electrical 42V, NO/NC, M10x1 | 5 µm | Nitrile | 1.5 bar | 05Q Microglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1005QLBG1EG20A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1¼ | 05QL Ecoglass * | Visual M10x1 | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1¼ * | 1,5 * | ||
| TTF1005QLBG1EG24A | Quote Required | TBD | Hydraulics | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1½ | 05QL Ecoglass * | Visual M10x1 | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1005QLBP2E2G243 | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Drilling Equipment | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 bar | -40 to 100 °C | 0 to 400 l/min | 2 x G1½ | No indicator, port plugged L+R | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T | ||||||
| TTF1005QLBP2E2G24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Power Packs | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 bar | -40 to 100 °C | 0 to 400 l/min | 2 x G1½ | No indicator, port plugged L+R | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | ||||||
| TTF1005QLBP2EG20A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1¼ | 05QL Ecoglass * | No indicator, port plugged L+R | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1¼ * | 1,5 * | ||
| TTF1005QLBP2EG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 psi | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Materials Handling | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 bar | -40 to 100 °C | 0 to 400 l/min | G1½ | 05QL Ecoglass * | No indicator, port plugged L+R | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1005QLBP2HG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 2 | -40 to 100 | 0 to 400 l/min | G1½ | 05QL Ecoglass * | No indicator, port plugged L+R | 5 µm | Nitrile | 2.0 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1½ * | 2 | ||
| TTF1005QLBS1EG20A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1¼ | 05QL Ecoglass * | Electrical 42V, NO/NC, M10x1 | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1¼ * | 1,5 * | ||
| TTF1005QLBS1EG243 | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 bar | Hydraulic & Industrial Process Filtration Division EMEA | Mobile Cranes | Materials Handling | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 bar | -40 to 100 °C | 0 to 400 l/min | G1½ | Electrical 42V, NO/NC, M10x1 | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T | ||||||
| TTF1005QLBS1EG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Wheel Loaders | Trucks and Buses | Parker | Hydraulic Oil Filters | 05QL Ecoglass | 1.5 | -40 to 100 | 0 to 400 l/min | G1½ | 05QL Ecoglass * | Electrical 42V, NO/NC, M10x1 | 5 µm | Nitrile | 1.5 bar | 05QL Ecoglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1010QBG1EG20A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Mobile Cranes | Trucks and Buses | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 | -40 to 100 | 0 to 540 l/min | G1¼ | 10Q Microglass * | Visual M10x1 | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T, no magnets | 500 * | G1¼ * | 1,5 * | ||
| TTF1010QBG1EG243 | Quote Required | TBD | Hydraulics | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 bar | Hydraulic & Industrial Process Filtration Division EMEA | Mobile Cranes | Construction | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 bar | -40 to 100 °C | 0 to 540 l/min | G1½ | Visual M10x1 | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T | ||||||
| TTF1010QBG1EG24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 | -40 to 100 | 0 to 540 l/min | G1½ | 10Q Microglass * | Visual M10x1 | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T, no magnets | 500 * | G1½ * | 1,5 * | ||
| TTF1010QBG2E2G24A | Quote Required | TBD | Hydraulics | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.2 bar | Hydraulic & Industrial Process Filtration Division EMEA | Power Packs | Trucks and Buses | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 bar | -40 to 100 °C | 0 to 540 l/min | 2 x G1½ | 10Q Microglass * | Visual G1/8 | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T, no magnets | 500 * | 2xG1½ | 1,5 * | ||
| TTF1010QBP2E2G24A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Construction | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 bar | -40 to 100 °C | 0 to 540 l/min | 2 x G1½ | 10Q Microglass * | No indicator, port plugged L+R | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T, no magnets | 500 * | 2xG1½ | 1,5 * | ||
| TTF1010QBP2EG20A | Quote Required | TBD | Filtration | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | Trucks and Buses | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 | -40 to 100 | 0 to 540 l/min | G1¼ | 10Q Microglass * | No indicator, port plugged L+R | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type T, no magnets | 500 * | G1¼ * | 1,5 * | ||
| TTF1010QBP2EG244 | Quote Required | TBD | Hydraulics | Tanktop Mounted Return Line Filter | Tanktop Mounted | 150 psi | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | No Indicator | Hydraulic & Industrial Process Filtration Division EMEA | Drilling Equipment | Construction | Parker | Hydraulic Oil Filters | 10Q Microglass | 1.5 bar | -40 to 100 °C | 0 to 540 l/min | G1½ | No indicator, port plugged L+R | 10 µm | Nitrile | 1.5 bar | 10Q Microglass | Diffuser type P |