- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve (bar)
- Bypass Valve Pressure Rating
- Connection Type
- Filter Element
- Filter Element Type
- Flow Capacity (l/min)
- Flow Rate
- Indicator Type
- Micron Rating
- Options
Filter by manufacturer
Tanktop Mounted Return Line Filter - TTF Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak back into the system during element change.
TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
Read More...TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
| Action | Part No. | Availability | Partner Available | Price | Operating Pressure | Division | Brand | Division | Product Series | Filter Element Type | Industry | Product Type | Operating Temperature | Bypass Valve Pressure Rating | Application | Technology | Indicator Pressure Setting | Product Style | Mounting Type | Port Connection Type | Bypass Valve Pressure Rating | Connection Type | Indicator Type | Options | Micron Rating | Flow Rate | Filter Element | Filter Element Type | Flow Capacity (l/min) | Bypass Valve (bar) | Seal Material | Specifications Met | Housing Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TTF1020QLBP2EG20A | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Materials Handling | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1¼ * | 1.5 bar | G1¼ | No indicator, port plugged L+R | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 1,5 * | Nitrile | ||||
| TTF1020QLBP2EG24A | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1½ * | 1.5 bar | G1½ | No indicator, port plugged L+R | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 1,5 * | Nitrile | ||||
| TTF1020QLBP2HG24A | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 2 | Refuse Trucks | Filtration | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1½ * | 2.0 bar | G1½ | No indicator, port plugged L+R | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 2 | Nitrile | ||||
| TTF1020QLBS1EG20A | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | 1.2 | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1¼ * | 1.5 bar | G1¼ | Electrical 42V, NO/NC, M10x1 | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 1,5 * | Nitrile | ||||
| TTF1020QLBS1EG243 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Wheel Loaders | Hydraulics | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | 1.5 bar | G1½ | Electrical 42V, NO/NC, M10x1 | Diffuser type T | 20 µm | 0 to 600 l/min | 20QL Ecoglass | Nitrile | ||||||||
| TTF1020QLBS1EG24A | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Construction | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | 1.2 | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1½ * | 1.5 bar | G1½ | Electrical 42V, NO/NC, M10x1 | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 1,5 * | Nitrile | ||||
| TTF1020QLBS2ELD245 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Construction | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Power Packs | Filtration | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | 1½"SAE-3000 + G1½ | 1.5 bar | 1½"SAE-3000 + G1½ | Electrical 42V, NO, G1/8 | No Diffuser, No Magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass * | 20QL Ecoglass | 500 * | 1,5 * | Nitrile | ||||
| TTF1020QLBS41 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 1.5 bar | G2 + G1½ | No indicator, ports plugged L+R | Diffuser type T, no magnets | 20 µm | 0 to 600 l/min | 20QL Ecoglass | Nitrile | |||||||||||||||||||||
| TTF1020QLVG1HG243 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 20QL Ecoglass | Construction | Hydraulic Oil Filters | -20 to 120 °C | 2 bar | Power Packs | Filtration | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | 2.0 bar | G1½ | Visual M10x1 | Diffuser type T | 20 µm | 0 to 600 l/min | 20QL Ecoglass | Fluoroelestomer | Degree of filtration determined by multipass test according to ISO 16889. | Aluminium | ||||||
| TTF2040WBG1EG125 | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 040W Wiremesh | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | 1.2 | Tanktop Mounted Return Line Filter | Tanktop Mounted | G3/4 * | 1.5 bar | G3/4 | Visual M10x1 | No Diffuser, No Magnets | 40 µm | 0 to 100 l/min | 040W Wiremesh | 040W Wiremesh | 60 | 1,5 * | Nitrile | ||||
| TTF2040WBP2EG161 | Quote Required | TBD | 150 psi | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 040W Wiremesh | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Drilling Equipment | Hydraulics | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | 1.5 bar | G1 | No indicator, port plugged L+R | No diffuser | 40 µm | 0 to 100 l/min | 040W Wiremesh | Nitrile | ||||||||
| TTF205QLBG1EG121 | Quote Required | TBD | 150 psi | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 05QL Ecoglass | Construction | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Power Packs | Filtration | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | G3/4 * | 1.5 bar | G3/4 | Visual M10x1 | No diffuser | 5 µm | 0 to 50 l/min | 05QL Ecoglass * | 05QL Ecoglass | 60 | 1,5 * | Nitrile | ||||
| TTF205QLVP2EG12E | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 05QL Ecoglass | Construction | Hydraulic Oil Filters | -20 to 120 °C | 1.5 bar | Power Packs | Hydraulics | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | 1.5 bar | G¾ | No indicator, port plugged L+R | 5 µm | 0 to 50 l/min | 05QL Ecoglass | Fluoroelestomer | Degree of filtration determined by multipass test according to ISO 16889. | Aluminium | |||||||
| TTF210CBPBG129 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10C Cellulose | Construction | Hydraulic Oil Filters | -40 to 100 °C | 0.8 bar | Mobile Cranes | Hydraulics | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | 0.8 bar | G3/4 | Visual M10x1 | Funnel with hose connection | 10 µm | 0 to 100 l/min | 10C Cellulose | Nitrile | ||||||||
| TTF210QBG1EG121 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Materials Handling | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Drilling Equipment | Filtration | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | G3/4 * | 1.5 bar | G3/4 | Visual M10x1 | No diffuser | 10 µm | 0 to 85 l/min | 10Q Microglass * | 10Q Microglass | 60 | 1,5 * | Nitrile | ||||
| TTF210QBG1EG123 | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | 1.2 | Tanktop Mounted Return Line Filter | Tanktop Mounted | G3/4 * | 1.5 bar | G3/4 | Visual M10x1 | Diffuser type T | 10 µm | 0 to 85 l/min | 10Q Microglass * | 10Q Microglass | 60 | 1,5 * | Nitrile | ||||
| TTF210QBG1EG129 | Quote Required | TBD | 10 bar | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 °C | 1.5 bar | Refuse Trucks | Hydraulics | 1.2 bar | Tanktop Mounted Return Line Filter | Tanktop Mounted | 1.5 bar | G3/4 | Visual M10x1 | Funnel with hose connection | 10 µm | 0 to 85 l/min | 10Q Microglass | Nitrile | ||||||||
| TTF210QBG1EG163 | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Power Packs | Hydraulics | 1.2 | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1 * | 1.5 bar | G1 | Visual M10x1 | Diffuser type T | 10 µm | 0 to 85 l/min | 10Q Microglass * | 10Q Microglass | 60 | 1,5 * | Nitrile | ||||
| TTF210QBP2EG123 | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Mobile Cranes | Filtration | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | G3/4 * | 1.5 bar | G3/4 | No indicator, port plugged L+R | Diffuser type T | 10 µm | 0 to 85 l/min | 10Q Microglass * | 10Q Microglass | 60 | 1,5 * | Nitrile | ||||
| TTF210QBP2EG161 | Quote Required | TBD | 150 | Hydraulic & Industrial Process Filtration Division EMEA | Parker | Hydraulic & Industrial Process Filtration Division EMEA | TTF Series | 10Q Microglass | Trucks and Buses | Hydraulic Oil Filters | -40 to 100 | 1.5 | Refuse Trucks | Filtration | No Indicator | Tanktop Mounted Return Line Filter | Tanktop Mounted | G1 * | 1.5 bar | G1 | No indicator, port plugged L+R | No diffuser | 10 µm | 0 to 85 l/min | 10Q Microglass * | 10Q Microglass | 60 | 1,5 * | Nitrile |