Replacement Elements - GS Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The high quality replacement elements of the GS filter series are available in a wide variety of sizes and with several filter materials and micron ratings.
These replacement elements ensure the quality of filtration Parker is known for.
Fluid passes through the elements in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates re-injection of contaminant during element change. Clean fluid then returns to the reservoir.
The GS series filters are available with Magnetic pre-filtration. The magnet column removes ferrous particles, even during times of bypass, and extends the life of the filter element.
Using genuine Parker replacement elements guarantees Parker’s quality of filtration. Using after market filters with unknown media quality may save initial cost, but can increase overall costs by requiring more element change outs and potentially causing system downtime. Protect your investment by always buying genuine Parker replacement elements.
Read More...These replacement elements ensure the quality of filtration Parker is known for.
Fluid passes through the elements in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates re-injection of contaminant during element change. Clean fluid then returns to the reservoir.
The GS series filters are available with Magnetic pre-filtration. The magnet column removes ferrous particles, even during times of bypass, and extends the life of the filter element.
Using genuine Parker replacement elements guarantees Parker’s quality of filtration. Using after market filters with unknown media quality may save initial cost, but can increase overall costs by requiring more element change outs and potentially causing system downtime. Protect your investment by always buying genuine Parker replacement elements.
| Action | Part No. | Availability | Partner Available | Price | Filter Element Type | Seal Material | Division | Maximum Pressure Differential | For Use With | Micron Rating | Options | Seal Material | Length | Filter Element Type | Diameter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 939182 | Quote Required | TBD | Cleanable metal mesh element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar (ISO 2941) | GS6 | 35 µm | Epoxy glued | Fluoroelastomer | 189 mm | 035W Wiremesh | 106 mm | ||
| 939183 | Quote Required | TBD | Cleanable metal mesh element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar (ISO 2941) | GS6 | 60 µm | Epoxy glued | Fluoroelastomer | 189 mm | 060W Wiremesh | 106 mm | ||
| 939184 | Quote Required | TBD | Cleanable metal mesh element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 | GS7 | 35 µm | Standard | Fluoroelastomer | 259 mm | 035W Wiremesh | 106 mm | ||
| 939185 | Quote Required | TBD | Cleanable metal mesh element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar (ISO 2941) | GS7 | 60 µm | Standard | Fluoroelastomer | 259 mm | 060W Wiremesh | 106 mm | ||
| 939190 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS2 | 125 µm | Epoxy clued | No seal | 149 mm | 125W Wiremesh | 72 mm | |||||
| 939191 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS6 | 125 µm | Standard | Fluoroelastomer | 189 mm | 125W Wiremesh | 106 mm | |||||
| 939192 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS7 | 125 µm | Standard | Fluoroelastomer | 259 mm | 125W Wiremesh | 106 mm | |||||
| 939196 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS7 | 500 µm | Standard | Fluoroelastomer | 259 mm | 500W Wiremesh | 106 mm | |||||
| 939213 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS6 | 300 µm | Standard | Nitrile | 189 mm | 300W Wiremesh | 106 mm | |||||
| 939293 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | GS7 | 15 µm | Standard | Fluoroelastomer | 259 mm | 15N Paper Cellulose | 106 mm | |||||
| 944476Q | Quote Required | TBD | Disposable element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar (ISO 2941) | GSN3 | 10 µm | Standard | Fluoroelastomer | 149 mm | 10Q Microglass | 72 mm | ||
| 944477Q | Quote Required | TBD | Disposable element | Fluoroelastomer | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar (ISO 2941) | GSN3 | 20 µm | Standard | Fluoroelastomer | 149 mm | 20Q Microglass | 72 mm |