- Availability & Price
- Search SKU
- Application Pressure Requirement
- Elastomer
- Electrical Connection
- Maximum Operating Voltage
- Mounting Style
- Orifice Size
- Valve Type
R9 Valve - 9 mm Miniature Diaphragm Isolation Valve
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker R9 valve delivers the liquid flow capabilities of a 16 mm valve in a 9 mm envelope. The R9 valve includes a 44% reduction in width with unrivaled flows and pressures up to 100 psi. Designed to offer low carryover performance with particulate and crystallization resistance, this valve is ideally suited for today’s demanding liquid handling applications. The R9 supports the performance requirements of current and future laboratory and portable instrumentation.
Markets:
• Clinical Diagnostics
• Analytical Chemistry
• Agent Detection
• Environmental Monitoring
Features/Benefits
• High pressure options available up to 100 PSI (6.9 bar)
• Easy mounting on 9 mm centers side to side, accommodating dispense over 96 well microplates
• Low unswept volume to minimize carryover
• Particulate and crystallization resistant
• 100% tested leak rate ensures a leak tight seal on every valve
• CE, REACH, and RoHS compliant
Applications:
• Sampling, Wash & Waste
• Reagent Addition
• Flow Control
• Clinical Diagnostics Instrumentation
• Hematology
• Automated Slide Stainers
• DNA/RNA Synthesis
| Action | Part No. | Availability | Partner Available | Price | Configuration | Length | Input Voltage | Maximum Operating Pressure | Maximum Operating Temperature | Actuation Type | Division | Operation Type | Minimum Operating Temperature | Power Consumption | For Fluid Type | Standard Lead Time | Out of Stock Lead Time | Leak Rate | Body Material | Mounting Type | Cycles per Lifetime | Seal Material | Orifice Size | Max Order Quantity | Connection Type | Valve Type | Electrical Connection | Weight | Height | Shipping Weight | Width | Function | Flow Rate | Response Time | Control Method | Connection Size | Maximum Flow Rate | Industry Application | Valve Type | Elastomer | Orifice Size | Mounting Style | Electrical Connection | Maximum Operating Voltage | Application Pressure Requirement |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| R9-224FF3LFF-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 4.1 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.76 mm | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | Wire Leads | 38.4 g | 37 mm | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 600 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 600 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.030 in (0.76 mm) | Face Seal Manifold Mount | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 60 psi (4.1 bar) | ||
| R9-224FF3LFP-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 60 psi | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.030 inch | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 1.46 inch | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 600 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 600 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.030 in (0.76 mm) | Face Seal Manifold Mount | 2.54 mm Male Pins | 24 Volt | VAC to 60 psi (4.1 bar) | ||
| R9-224FF3LMF-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 60 psi | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.76 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 1.35 oz | 1.46 inch | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 600 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 600 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.030 in (0.76 mm) | M6 | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 60 psi (4.1 bar) | ||
| R9-224FF3LMP-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 4.1 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.030 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 1.46 inch | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 600 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 600 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.030 in (0.76 mm) | M6 | 2.54 mm Male Pins | 24 Volt | VAC to 60 psi (4.1 bar) | ||
| R9-224FF6H4F-000 | Quote Required | TBD | n/a | 68.8 mm | 24 VDC | 40 psi | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 38.4 g | 1.46 inch | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | 1/4-28 | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6H4P-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 40 psi | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 37 mm | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | 1/4-28 | 2.54 mm Male Pins | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6HFF-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 2.8 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | Wire Leads | 1.35 oz | 37 mm | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | Face Seal Manifold Mount | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6HFP-000 | Quote Required | TBD | n/a | 68.8 mm | 24 VDC | 2.8 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 37 mm | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | Face Seal Manifold Mount | 2.54 mm Male Pins | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6HMF-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 2.8 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 38.4 g | 37 mm | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | M6 | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6HMP-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 40 psi | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.061 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 1.35 oz | 1.46 inch | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 700 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 700 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | M6 | 2.54 mm Male Pins | 24 Volt | VAC to 40 psi (2.8 bar) | ||
| R9-224FF6L4F-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 20 psi | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 1.35 oz | 37 mm | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | 1/4-28 | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-224FF6L4P-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 1.4 bar | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.061 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 1.35 oz | 37 mm | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | 1/4-28 | 2.54 mm Male Pins | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-224FF6LFF-000 | Quote Required | TBD | n/a | 68.8 mm | 24 VDC | 20 psi | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | Wire Leads | 1.35 oz | 1.46 inch | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | Face Seal Manifold Mount | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-224FF6LFP-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 1.4 bar | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 1.55 mm | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 37 mm | 0.35 oz | 8.7 mm | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | Face Seal Manifold Mount | 2.54 mm Male Pins | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-224FF6LMF-000 | Quote Required | TBD | n/a | 68.8 mm | 24 VDC | 20 psi | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.061 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 38.4 g | 1.46 inch | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | M6 | 18 in(46 cm) Flying Leads | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-224FF6LMP-000 | Quote Required | TBD | n/a | 2.71 inch | 24 VDC | 1.4 bar | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.2 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | FFKM | 0.061 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 1.35 oz | 37 mm | 0.35 oz | 0.34 inch | 2-Way, Normally Closed (NC) | Up to 580 ml/min | < 18 ms max cycling | Hit and hold circuit | M6 threaded port connections | 580 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 2-Way Normally Closed | FFKM | 0.061 in (1.55 mm) | M6 | 2.54 mm Male Pins | 24 Volt | VAC to 20 psi (1.36 bar) | ||
| R9-312EP3H4F-000 | Quote Required | TBD | n/a | 68.8 mm | 12 VDC | 100 psi | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | EPDM | 0.030 inch | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | Wire Leads | 1.35 oz | 1.46 inch | 0.35 oz | 8.7 mm | 3-Way, Universal | Up to 900 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 900 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 3-Way Universal | EPDM | 0.030 in (0.76 mm) | 1/4-28 | 18 in(46 cm) Flying Leads | 12 Volt | VAC to 100 psi (6.9 bar) | ||
| R9-312EP3H4P-000 | Quote Required | TBD | n/a | 68.8 mm | 12 VDC | 6.9 bar | 122 °F | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | EPDM | 0.76 mm | 10 | Threaded Port Connections | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 1.35 oz | 37 mm | 0.35 oz | 8.7 mm | 3-Way, Universal | Up to 900 ml/min | < 18 ms max cycling | Hit and hold circuit | 1/4-28 UNF threaded port connections | 900 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 3-Way Universal | EPDM | 0.030 in (0.76 mm) | 1/4-28 | 2.54 mm Male Pins | 12 Volt | VAC to 100 psi (6.9 bar) | ||
| R9-312EP3HFF-000 | Quote Required | TBD | n/a | 2.71 inch | 12 VDC | 6.9 bar | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 0 °C | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | EPDM | 0.030 inch | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | Wire Leads | 38.4 g | 1.46 inch | 0.35 oz | 8.7 mm | 3-Way, Universal | Up to 900 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 900 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 3-Way Universal | EPDM | 0.030 in (0.76 mm) | Face Seal Manifold Mount | 18 in(46 cm) Flying Leads | 12 Volt | VAC to 100 psi (6.9 bar) | ||
| R9-312EP3HFP-000 | Quote Required | TBD | n/a | 2.71 inch | 12 VDC | 6.9 bar | 50 °C | Solenoid | Precision Fluidics Division | Electronic | 32 °F | 1.8 W | Liquids | 20 | 40 | Bubble Tight | PEEK | Mounting Screw | 10 Million | EPDM | 0.030 inch | 10 | Manifold Face Seal | Diaphragm Rocker Isolation Valve | 2.54 mm pins | 38.4 g | 1.46 inch | 0.35 oz | 8.7 mm | 3-Way, Universal | Up to 900 ml/min | < 18 ms max cycling | Hit and hold circuit | Manifold face seal | 900 ml/min | Clinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste | 3-Way Universal | EPDM | 0.030 in (0.76 mm) | Face Seal Manifold Mount | 2.54 mm Male Pins | 12 Volt | VAC to 100 psi (6.9 bar) |